High precision system for magnetic field measurements of insertion devices of the Brazilian Synchroton Light Source

dc.creatorTosin, Giancarlo
dc.date2005
dc.date2005-05-12T00:00:00Z
dc.date2017-03-28T21:43:07Z
dc.date2017-07-13T19:48:50Z
dc.date2017-03-28T21:43:07Z
dc.date2017-07-13T19:48:50Z
dc.date.accessioned2018-03-29T03:55:10Z
dc.date.available2018-03-29T03:55:10Z
dc.identifier(Broch.)
dc.identifierTOSIN, Giancarlo. Sistema de alta precisão para as medições dos campos magneticos dispositivos de inserção do Laboratorio Nacional de Luz Sincroton. 2005. 129p. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e Computação, Campinas, SP. Disponível em: <http://libdigi.unicamp.br/document/?code=vtls000379242>. Acesso em: 28 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/260522
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1338198
dc.descriptionOrientador: Evandro Conforti
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e Computação
dc.descriptionResumo: As medições acuradas e precisas do campo magnético dos dispositivos de inserção (DIs) são essenciais para garantir que suas instalações no Anel de Armazenamento de Elétrons do Laboratório Nacional de Luz Síncrotron (LNLS) alcançarão o desempenho desejado e não comprometerão a estabilidade do feixe de elétrons estocado. Tais dispositivos são versáteis fontes de radiação introduzidas nos Anéis de Armazenamento onde, a partir dos seus perfis de campos, promovem a emissão de intensos fluxos de fótons, de largo espectro ou monocromáticos, cuja polarização também pode ser controlada. Devido às características do feixe de elétrons do Anel de Armazenamento do LNLS, tais como energia de operação, energia de injeção e abertura dinâmica (região onde o feixe é estável), severas restrições na qualidade do campo são impostas para garantir o tempo de vida e a estabilidade da órbita. Para a verificação dessas especificações e do perfil do campo, que é fundamental para a determinação do espectro emitido, construiu-se uma bancada de caracterização com alcance útil de 4,2 m. Duas técnicas foram nela instaladas: bobina girante, para a medida de campos médios (ou integrados), e sensores Hall, para a medição de campos locais. Ambas as técnicas foram exploradas nos seus conceitos, e aperfeiçoadas, a fim de assegurar a confiabilidade dos valores medidos, dentro de suas especificações. O aperfeiçoamento das técnicas aqui proposto permitiu melhorar substancialmente a precisão apresentada na literatura especializada
dc.descriptionAbstract: This Thesis was a consequence of the need for an accurate and precise magnetic field measurement bench for insertion devices characterization (IDs). Such devices are versatile radiation sources installed in Electron Storage Rings. From their magnetic field profile, they provide high photon fluxes, with broad or monochromatic spectrum, being possible, depending on the ID geometry, to control also the radiation polarization. Due to some features of the LNLS electron beam, such as injection energy, operation energy and dynamic aperture, severe restrictions are imposed on the magnetic field quality to assure a long life time and a stable beam orbit. A characterization bench, 4.2 m in length, was built to verify such specifications and to determine the field profile, which is correlated to the emission spectrum. Two techniques were implemented in this bench: rotating coil, for average (or integrated) field measurements, and Hall probes, for local field measurements. Both techniques were conceptually explored and improved to guarantee the reliability of the measured values within their specifications. The results showed a considerable increasing in the precision with respect to values presented in the scientific literature
dc.descriptionDoutorado
dc.descriptionEletrônica, Microeletrônica e Optoeletrônica
dc.descriptionDoutor em Engenharia Eletrica
dc.format129p. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectAneis de armazenamento
dc.subjectDispositivos magnéticos
dc.subjectHall, Efeito
dc.subjectBobinas
dc.subjectDetectores
dc.subjectAceleradores de partículas
dc.subjectParticle storage rings
dc.subjectMagnetic devices
dc.subjectHall effect
dc.subjectCoils, Electric
dc.subjectDetectors
dc.subjectAccelerators, Particle
dc.titleSistema de alta precisão para as medições dos campos magneticos dispositivos de inserção do Laboratorio Nacional de Luz Sincroton
dc.titleHigh precision system for magnetic field measurements of insertion devices of the Brazilian Synchroton Light Source
dc.typeTesis


Este ítem pertenece a la siguiente institución