Análise comparativa do desempenho das manobras de religamento monopolar e tripolar para eliminação de faltas monofásicas em linhas de transmissão

dc.creatorYektaei, Hossein, 1986-
dc.date2016
dc.date2016-08-31T00:00:00Z
dc.date2017-04-17T19:03:02Z
dc.date2017-07-13T19:47:07Z
dc.date2017-04-17T19:03:02Z
dc.date2017-07-13T19:47:07Z
dc.date.accessioned2018-03-29T03:53:41Z
dc.date.available2018-03-29T03:53:41Z
dc.identifierYEKTAEI, Hossein. Comparative analysis of single-phase and three-phase auto reclosing maneuver to eliminate line to ground fault in transmission lines = Análise comparativa do desempenho das manobras de religamento monopolar e tripolar para eliminação de faltas monofásicas em linhas de transmissão. 2016. 1 recurso online (70 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/321723
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1337835
dc.descriptionOrientador: Maria Cristina Dias Tavares
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação
dc.descriptionResumo: Um sistema de energia elétrica compreende geração, transmissão e distribuição de energia elétrica. As linhas de transmissão são usadas para transmitir energia elétrica a centros de carga distantes. O rápido crescimento dos sistemas de energia elétrica nas últimas décadas resultou em um grande aumento do número de linhas em operação e seu comprimento total. Para níveis de transmissão EHV (extra alta tensão), entre 90-95% de todas as falhas de linha envolvem apenas uma única fase. Destes, mais de 90% são temporários e podem ser compensados ??por três fases de religamento; Conseqüentemente, faltas fase-terra têm recebido a maior atenção em estudos de sistema. Este projeto analisa as entidades da linha de transmissão resultantes da eliminação de uma falta monofásica usando o SPAR (Auto-Reclusão Monofásica) e o religamento automático trifásico na linha de transmissão de 400 kV. O projeto analisa a influência de diferentes parâmetros do sistema, como nível de compensação, comprimento da linha e local da falta, juntamente com o método de mitigação. Para o estudo de simulação, PSCAD / EMTDC é selecionado como o software de simulação
dc.descriptionAbstract: An electric power system comprises of generation, transmission and distribution of electric energy. Transmission lines are used to transmit electric power to distant large load centers. The rapid growth of electric power systems over the past few decades has resulted in a large increase of the number of lines in operation and their total length. For EHV (extra high voltage) transmission levels, between 90¿95% of all line faults involve only a single phase. Of these, more than 90% are temporary and can be cleared by three phase reclosing; consequently, phase-to-ground faults have received the most attention in system studies. This project analyzes the transmission line entities resulting from elimination of a single-phase fault by using the SPAR (Single-Phase Auto-Reclosing) and three-phase auto-reclosing on the 400 kV transmission line. The project analyzes the influence of different system parameters like compensation level, line length and fault location together with the mitigation method. For the simulation study, PSCAD/EMTDC is selected as the simulation software
dc.descriptionMestrado
dc.descriptionEnergia Eletrica
dc.descriptionMestre em Engenharia Elétrica
dc.descriptionCAPES
dc.format1 recurso online (70 p.) : il., digital, arquivo PDF.
dc.formatapplication/pdf
dc.languageInglês
dc.publisher[s.n.]
dc.relationRequisitos do sistema: Software para leitura de arquivo em PDF
dc.subjectLinhas elétricas - Transmissão
dc.subjectModelagem e simulação
dc.subjectSistemas elétricos de potência
dc.subjectSistemas de energia elétrica - Proteção
dc.subjectPower lines - Transmission
dc.subjectModeling and simulation
dc.subjectElectrical power systems
dc.subjectElectric power systems - Protection
dc.titleComparative analysis of single-phase and three-phase auto reclosing maneuver to eliminate line to ground fault in transmission lines = Análise comparativa do desempenho das manobras de religamento monopolar e tripolar para eliminação de faltas monofásicas em linhas de transmissão
dc.titleAnálise comparativa do desempenho das manobras de religamento monopolar e tripolar para eliminação de faltas monofásicas em linhas de transmissão
dc.typeTesis


Este ítem pertenece a la siguiente institución