Effect of mechanical brushing and ageing by thermal cycling on hardness and roughness surface of resilient soft liners

dc.creatorHermann, Caio
dc.date2005
dc.date2005-02-24T00:00:00Z
dc.date2017-03-28T14:00:10Z
dc.date2017-07-12T19:24:52Z
dc.date2017-03-28T14:00:10Z
dc.date2017-07-12T19:24:52Z
dc.date.accessioned2018-03-29T03:45:10Z
dc.date.available2018-03-29T03:45:10Z
dc.identifier(Broch.)
dc.identifierHERMANN, Caio. Efeito da escovação mecanica e da termociclagem sobre dureza e rugosidade superficiais de reembasadores resilientes. 2005. 83f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: <http://libdigi.unicamp.br/document/?code=vtls000350054>. Acesso em: 28 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/289925
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1335768
dc.descriptionOrientador: Marcelo Ferraz Mesquita
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
dc.descriptionResumo: Este trabalho teve como objetivo avaliar o efeito da escovação mecânica e termociclagem sobre dureza e rugosidade superficiais de três materiais reembasadores resilientes considerados definitivos, dois à base de silicone, um auto (Sofreliner MS) e outro termopolimerizável (Molloplast-B), além de um à base de resina acrílica autopolimerizável (Dentuflex). Para a confecção das amostras, foram utilizadas matrizes de silicone polimerizado por reação de condensação incluídas em muflas, obtendo um molde impresso no gesso posteriormente preenchido com os materiais resilientes. Foram confeccionadas 60 amostras, submetidas à leitura de rugosidade superficial num rugosímetro SURFCORDER SE 1700 (Kosaka Laboratory) e à leitura de dureza num durômetro Shore A (GS ¿ 709 Teclock, Osaka, Japão). Em seguida as amostras foram separadas em dois grupos, onde metade foi submetida ao ensaio de termociclagem numa máquina MSCT ¿ 3 PLUS regulada em 2.000 ciclos com banhos alternados de 60 segundos a 5±1oC e 55±1oC e a outra metade ao ensaio de escovação mecânica numa máquina MSEt, seguida de termociclagem. O ensaio de escovação foi executado sob carga estática de 200 g, com movimentos lineares, totalizando 30.000 ciclos, onde uma solução de dentifrício contendo água era liberada a cada 1 minuto sobre as amostras. Após os ensaios, foram executadas novas leituras de dureza e rugosidade superficial. Os valores obtidos foram submetidos à análise de variância em parcelas subdivididas no tempo, seguida do teste de Tukey em nível de 5% de significância. O material Dentuflex apresentou os maiores valores médios de rugosidade e dureza iniciais, seguidos do Molloplast-B e Sofreliner MS. Após termociclagem, os materiais Dentuflex e Sofreliner MS apresentaram aumento estatisticamente significante da dureza. Após escovação, o material Dentulfex apresentou diminuição nos valores de rugosidade e o Sofreliner MS aumento, ambos estatisticamente significantes. Após a escovação seguida de termociclagem, todos os materiais apresentaram valores de rugosidade estatisticamente semelhantes entre si, provavelmente devido ao polimento do material Dentuflex, abrasão do Sofreliner MS e preservação das características do Molloplast-B
dc.descriptionAbstract: The aim of this study was to evaluate the effect of mechanical brushing and thermocycling on hardness and roughness of three resilient definitive lining materials: 1) auto (Sofreliner MS), 2) heat-polymerized (Molloplast-B) silicone bases; and 3) auto-polymerized plasticized acrylic resin (Dentuflex). To prepare the samples, silicone rubber matrixes were made and placed in a flask to obtain a cast pressed mold, and then filled with resilient lining materials, handled according to the manufacturer¿s directions. All samples were submitted to surface roughness readings in a roughness readings machine (SURFCORDER SE 1700 ¿ Kosaka Laboratory) and hardness readings in a Shore A durometer (GS ¿ 709 Teclock, Osaka, Japan). After the readings, the samples were assigned into 6 groups of 10 each, half of which were submitted to thermocycling treatment in a thermal cycler machine (MSCT ¿ 3 PLUS) for 2.000 cycles at temperatures ranging from 5±1oC to 55±1oC and a 60-second dwell time. The other half was submitted to a mechanical brushing simulation in an MSEt brushing machine followed by thermocycling. The samples were submitted to 30.000 strokes with linear brushing movements, under a 200 g static load pressure. Toothpaste solution was injected every one-minute break. Then new readings of hardness and roughness were done, and the values were submitted to variance analysis test followed by Tukey test, with 5% of significance. Dentuflex showed the highest initial values for both roughness and hardness, followed by Molloplast-B and Sofreliner MS. After thermocycling, Dentuflex and Sofreliner-MS showed a statistically significant increase in hardness values. After mechanical brushing, Dentuflex showed a decrease and Sofreliner MS an increase in roughness values. After mechanical brushing followed by thermocycling, all materials showed similar roughness values (statistically significant), probably due to the Dentuflex polished surface, the Sofreliner MS abrasion and the remained features of the Molloplast-B
dc.descriptionMestrado
dc.descriptionProtese Dental
dc.descriptionMestre em Clinica Odontologica
dc.format83f. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectPrótese dentária completa
dc.subjectMateriais dentários
dc.subjectDenture, Complete
dc.subjectDental materials
dc.titleEfeito da escovação mecanica e da termociclagem sobre dureza e rugosidade superficiais de reembasadores resilientes
dc.titleEffect of mechanical brushing and ageing by thermal cycling on hardness and roughness surface of resilient soft liners
dc.typeTesis


Este ítem pertenece a la siguiente institución