A three-dimensional Finite Element Analysis of the biomechanical behavior of overdenture bar-clip system relined with soft or hard permanent material

dc.creatorSilva, Tales Candido Garcia da, 1987-
dc.date2013
dc.date2017-04-01T16:00:38Z
dc.date2017-07-12T19:21:35Z
dc.date2017-04-01T16:00:38Z
dc.date2017-07-12T19:21:35Z
dc.date.accessioned2018-03-29T03:41:59Z
dc.date.available2018-03-29T03:41:59Z
dc.identifierSILVA, Tales Candido Garcia da. Análise tridimensional por elementos finitos do comportamento biomecânico de overdenture com sistema barra-clipe reembasada com material permanente macio ou rígido. 2013. 75 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/288543
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1334993
dc.descriptionOrientador: Rafael Leonardo Xediek Consani
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
dc.descriptionResumo: O processo de reabsorção do osso mandibular e do peri-implantar promove desadaptação das bases protéticas, causando aumento das tensões geradas pelas próteses e componentes, exacerbando a reabsorção óssea. Com o intuito de readaptar bases protéticas ao rebordo subjacente, o uso de reembasadores tem sido indicado. O objetivo neste trabalho foi analisar pelo método de Elementos Finitos as tensões no osso peri-implantar, rebordo posterior e componente protéticos em overdenture com reabsorção óssea simulada (na instalação da prótese, 3, 5 e 10 anos de uso) e reembasamento com materiais permanentes macio ou rígido. Foi utilizado software específico para modelagem (SolidWorks 2010) para a geração tridimensional dos componentes protéticos e base da mandíbula. Foram gerados quatro modelos mandibulares, que simulavam as perdas ósseas do rebordo posterior e peri-implantar, de acordo com os tempos avaliados neste estudo e com ou sem o uso de reembasadores macios ou rígidos. Os modelos por Elementos Finitos foram obtidos com a exportação dos modelos sólidos para software específico de simulação mecânica (ANSYS Workbench 11), com carga de 100 N na região do primeiro molar direito. O modelo que simula o momento da instalação da prótese gerou os menores resultados de tensão para todos os componentes e situações analisadas. A distribuição de tensões nos modelos com 3, 5 e 10 anos de reabsorção foi semelhante quando se avaliou a localização das tensões; entretanto, maior acúmulo foi verificado nos componentes protéticos e tecido ósseo, sempre ao lado de aplicação da carga. Quanto mais tempo de reabsorção, maiores eram os valores de tensão gerados, com influência dos materiais reembasadores que diminuíram os valores tensionais. Materiais reembasadores rígidos promoveram melhor distribuição e menores valores de tensão que reembasadores macios, sendo mais eficientes que os modelos sem material reembasador. Conclui-se que: a) o aumento da reabsorção dos rebordos posterior ou peri-implantar promoveu aumento de tensões tanto nos componentes protéticos como no tecido ósseo; b) o uso de reembasadores macio ou rígido atenuou as tensões geradas, qualquer que fosse à resiliência do material; c) o reembasador rígido foi mais eficiente na diminuição das tensões quando comparado ao reembasador macio
dc.descriptionAbstract: The process of ridge posterior and peri-implant bone resorption promotes misfit between overdenture base and mandibular ridge, which culminates in increased stresses generated by prostheses and their components, exacerbating bone resorption. Relines have being used in order to readapt the prosthetic bases. This three-dimensional finite elements method study aimed to evaluate the effect stress of a overdenture in models that simulated bone resorption (in installing prosthesis, 3, 5 and 10 years of use) and reline materials (soft or hard) on stress distribution in posterior ridge, surrounding bone and implant prosthetic components. Through the computer aided design software (SolidWorks 2010), three-dimensional prosthetic components were built and jaw models from images of the mandible computerized tomography. Four models were generated simulating mandibular bone loss according to times and use of hard or soft relines. These geometric models were obtained through export to the specific mechanical simulation software (ANSYS Workbench 11), and subjected to a load of 100 N in the first right molar region. The lowest observed values were in the period of installation prosthesis for all components and situations. The stress distributions in models with 3, 5 and 10 years of resorption were similar considering the location of tensions; however, the stress concentration increased values in the prosthetic components and bone, always on the side of load application. The longer resorption, the higher stress values were generated, with the Influence of reline materials. Hard reline materials promoted better distribution and lower stress values than soft reline, demonstrating models with more effectiveness than in with no reline. It can be concluded that: a) the power increase of posterior ridge or peri-implant bone resorption promotes increased tensions in the prosthetic components in the bone tissue, b) the use of soft or hard relines, minimized the generated tensions, regardless the stuff resilience, c) the hard reline was more efficient in reducing tensions when compared to soft reline
dc.descriptionMestrado
dc.descriptionMateriais Dentarios
dc.descriptionMestre em Materiais Dentários
dc.format75 f. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectReabsorção óssea
dc.subjectImplantes dentários
dc.subjectPrótese dentária
dc.subjectBone resorption
dc.subjectDental implants
dc.subjectDental prosteshis
dc.titleAnálise tridimensional por elementos finitos do comportamento biomecânico de overdenture com sistema barra-clipe reembasada com material permanente macio ou rígido
dc.titleA three-dimensional Finite Element Analysis of the biomechanical behavior of overdenture bar-clip system relined with soft or hard permanent material
dc.typeTesis


Este ítem pertenece a la siguiente institución