Evaluation of dentinal microcracks after in vivo root canal preparation with Reciproc instruments using two chemicals auxiliary substances

dc.creatorHartmann, Mateus Silveira Martins, 1976-
dc.date2016
dc.date2016-11-30T00:00:00Z
dc.date2017-04-19T15:20:07Z
dc.date2017-07-12T19:18:33Z
dc.date2017-04-19T15:20:07Z
dc.date2017-07-12T19:18:33Z
dc.date.accessioned2018-03-29T03:39:05Z
dc.date.available2018-03-29T03:39:05Z
dc.identifierHARTMANN, Mateus Silveira Martins. Avaliação de microtrincas dentinárias após o preparo do canal radicular "in vivo" com instrumentos Reciproc utilizando duas substâncias químicas auxiliares. 2016. 1 recurso online (79 p.). Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/321768
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1334290
dc.descriptionOrientador: Alexandre Augusto Zaia
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
dc.descriptionResumo: O preparo dos canais radiculares é um dos principais passos para atingir o sucesso do tratamento endodôntico, com limpeza e forma adequada ao canal radicular, eliminação de bactérias e remoção de detritos, permite a obturação tridimensional do sistema de canais radiculares. A instrumentação dos canais radiculares pode ser executada com instrumentos manuais ou mecanizados com rotação contínua ou reciprocante. Entretanto esses instrumentos podem causar microtrincas dentinárias. Dessa forma, o objetivo do presente estudo foi avaliar in vivo a ocorrência de microtrincas dentinárias em dentes vitais, após instrumentação endodôntica, utilizando instrumentos de uso único, com movimento reciprocante (Reciproc), associado a duas diferentes substâncias químicas auxiliares, a clorexidina gel 2% e o hipoclorito de sódio 5,25%. 20 dentes incisivos inferiores de cinco pacientes foram preparados in vivo, com instrumentos Reciproc R40 (40/.06). Dois dentes de cada paciente foram alocados em cada grupo experimental, utilizando uma substância química auxiliar diferente: Grupo 1 (n=10) ¿ hipoclorito de sódio 5,25% e Grupo 2 (n=10) ¿ clorexidina gel 2%. Após o preparo, os dentes foram extraídos e observados em toda a sua extensão, do ápice até a junção amelocementária com auxílio de microtomografia computadorizada. Os resultados demonstraram ausência de microtrincas dentinárias do interior para o exterior dos canais radiculares após a análise das imagens em todos os dentes. Esses resultados sugerem que o preparo dos canais radiculares efetuado com os instrumentos Reciproc R40 in vivo, em dentes com polpa vital, é seguro e não causa microtrincas dentinárias nos canais radiculares de incisivos inferiores, independentemente da substância química auxiliar utilizada
dc.descriptionAbstract: The preparation of root canals is one of the key steps to achieve the success of endodontic treatment, cleaning and shaping adequately to the root canal and the bacteria and debris removal, allows three-dimensional obturation of the root canal system. The root canal instrumentation can be performed with manual or mechanized instruments with continuous rotation or reciprocating. However, these instruments can cause dentinal microcracks. The aim of this study was to evaluate in vivo if there are dentinal microcracks in vital teeth after endodontic instrumentation using single-use instruments, with reciprocating movement (Reciproc), associated to two different auxiliary chemical substances, chlorhexidine gel 2% and sodium hypochlorite 5.25%. 20 lower incisor teeth of five patients were prepared in vivo, with Reciproc R40 instruments (40/.06). Two teeth from each patient were allocated to each experimental group, using a different chemical auxiliary substance: Group 1 (n=10) - sodium hypochlorite 5.25% and Group 2 (n=10) - 2% chlorhexidine gel. After preparation, the teeth were extracted and observed in its entire lenght, the apex to the amelocemental junction with the aid of micro-CT. The results showed the absence of dentinal microcracks the inside to the outside of the root canals after the analysis of images in all teeth. The results suggest that the preparation of root canals performed with Reciproc R40 instruments in vivo, in teeth with vital pulp, it is safe and does not cause dentinal microcracks in root canals of mandibular incisors, regardless of auxiliary chemical substance used
dc.descriptionDoutorado
dc.descriptionEndodontia
dc.descriptionDoutor em Clínica Odontológica
dc.format1 recurso online (79 p.) : il., digital, arquivo PDF.
dc.formatapplication/pdf
dc.publisher[s.n.]
dc.relationRequisitos do sistema: Software para leitura de arquivo em PDF
dc.subjectEndodontia
dc.subjectTratamento do canal radicular
dc.subjectMicrotomografia por raio-X
dc.subjectEndodontics
dc.subjectRoot canal therapy
dc.subjectX-Ray Microtomography
dc.titleAvaliação de microtrincas dentinárias após o preparo do canal radicular "in vivo" com instrumentos Reciproc utilizando duas substâncias químicas auxiliares
dc.titleEvaluation of dentinal microcracks after in vivo root canal preparation with Reciproc instruments using two chemicals auxiliary substances
dc.typeTesis


Este ítem pertenece a la siguiente institución