Bond strenght of self-etch adhesives in vivo dentin in class I cavity

dc.creatorPutrick, Laélia Maria, 1961-
dc.date2011
dc.date2017-04-01T00:34:49Z
dc.date2017-07-12T19:17:33Z
dc.date2017-04-01T00:34:49Z
dc.date2017-07-12T19:17:33Z
dc.date.accessioned2018-03-29T03:38:02Z
dc.date.available2018-03-29T03:38:02Z
dc.identifierPUTRICK, Laélia Maria. Resistência de união de adesivos autocondicionantes in vivo em cavidade classe I em dentina. 2011. 73 p. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=000820662>. Acesso em: 31 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/288152
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1334034
dc.descriptionOrientador: Mario Fernando de Goes
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
dc.descriptionResumo: Este estudo avaliou in vivo em uma semana e em seis meses, o desempenho de resistência de união de dois adesivos autocondicionantes a dentina. Cavidades Classe I (3 x 5 x 4mm) foram preparadas em molares humanos livres de cáries (n = 25). Procedimentos de união foram realizados utilizando dois sistemas de adesivo autocondicionante (Adper Easy One (EO) e Filtek Silorane (S), 3M/ ESPE), conforme a instrução do fabricante. A resina composta ä base de metacrilato (Filtek Z350, 3M/ESPE) foi aplicada utilizando a técnica oblíqua incremental para os grupos Adper Easy One. A resina composta á base de Silorano (Filtek Silorano, 3M/ESPE) foi inserida utilizando incremenos horizontais de 2 milímetros. A fotopolimerização foI realizada por meio de luz visível emitida por LED (1250mW/cm2). Os dentes foram extraídos após uma semana (EO n = 8, S n = 6) e seis meses (EO n = 4, S n = 7). Após 2 meses de armazenamento em solução de glutaraldeído 10% (4ºC), os dentes foram seccionados e obtidos esp (secção de 0,8 ± 0.1mm2). Os corpos-de-prova foram submetidos ao teste de tração, utilizando uma máquina universal de ensaios (Instron) sob velocidade transversal de 1,0mm/min. Os tipos de fratura foram observados no MEV. Os dados foram analisados por testes de ANOVA e Tukey (p ? 0,05). Os valores médios (MPa ± SD) do Adper Easy One (1 semana = 21,4 ± 6,0; 6 mêses = 17,6 ± 4,3) e Silorano (1 semana = 20,0 ± 9,2; 6 meses = 13,3 ± 5,0) não diferiram estatisticamente entre os adesivos para os dois períodos avaliados. Na análise do padrão de fratura em MEV, os dois sistemas adesivos, nos dois tempos avaliados, apresentaram predominância de fraturas coesivas no adesivo. Entretanto, também apresentaram em menor percentual fraturas envolvendo a camada híbrida, fraturas coesiva na resina composta, e fraturas coesivas em dentina. Os resultados do teste de tração indicaram que os valores de resistência de união não se alteraram para os dois adesivos autocondicionantes após seis meses no meio bucal
dc.descriptionAbstract: The following study has evaluated in vivo, in a time period of a week and six months, the performance of bond endurance of two self-etch adhesives to dentin. Class I cavities (4 x 7 x 4 mm) were prepared in caries-free human molars (n = 25). Bond procedures were performed using two systems of self-etch adhesives (Adper Easy One (EO) and Filtek Silorane (S), 3M / ESPE), according to the manufacturer's instructions. A resin composed by methacrylate (Filtek Z350, 3M/ESPE) was applied using an oblique incremental technique for groups Adper Easy. In addition, another type of resin, composed by Silorano (Filtek Silorano, 3M/ESPE), was inserted through a horizontal incremental technic of 2 mm. Procedures were performed using a photopolymerization LED (1250mW/cm2). The teeth were extracted a week (EO n = 8, S n = 6) and six months later (EO n = 4, S n = 7). After 2 months in 10% glutaraldehyde solution(4 ºC), the teeth were cut and it has been obtained ten "especimes" (section 0.8 ± 0.1mm2). The bodies of the test piece were tested in microtensile using a universal testing machine (Instron) at a traverse speed of 1,0 mm / min. Fracture modes have been observed in SEM. Data were analyzed by ANOVA and Tukey tests (p ? 0.05). Medium MPa Adper Easy One (1 week = 21.4 ± 6.0, 6 months = 17.6 ± 4.3) and Silorane (1 week = 20.0 ± 9.2, 13.3 ± 6 months = 5.0). There were no statistically significant value differences between the adhesive in both experimental periods tested. Analysis of fracture pattern in the SEM two adhesive systems, once they had been evaluated, showed a predominantly cohesive fracture in the adhesive. However, they have also had a lower percentage of fractures regarding the hybrid layer, cohesive fractures in resin composition, and cohesive fractures in dentin. In vivo results have indicated that the two self-etch adhesives and the bond resistance values have not been altered after six months in the oral environment
dc.descriptionDoutorado
dc.descriptionMateriais Dentarios
dc.descriptionDoutor em Materiais Dentarios
dc.format73 p. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectDentes
dc.subjectDente molar
dc.subjectMetacrilatos
dc.subjectFotopolimerização
dc.subjectTeeth
dc.subjectMolar
dc.subjectMethacrylates
dc.subjectPhotopolymerization
dc.titleResistência de união de adesivos autocondicionantes in vivo em cavidade classe I em dentina
dc.titleBond strenght of self-etch adhesives in vivo dentin in class I cavity
dc.typeTesis


Este ítem pertenece a la siguiente institución