Evaluation of application of folic acid in aerobic wastewater treatment

dc.creatorKameyama, Oswaldo
dc.date2007
dc.date2007-03-23T00:00:00Z
dc.date2017-03-29T10:43:11Z
dc.date2017-07-07T19:26:13Z
dc.date2017-03-29T10:43:11Z
dc.date2017-07-07T19:26:13Z
dc.date.accessioned2018-03-29T03:19:23Z
dc.date.available2018-03-29T03:19:23Z
dc.identifier(Broch.)
dc.identifierKAMEYAMA, Oswaldo. Avaliação da aplicação de acido folico em tratamento aerobio de aguas residuarias. 2007. 85f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=vtls000411556>. Acesso em: 29 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/255465
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1329406
dc.descriptionOrientador: Ranulfo Monte Alegre
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos
dc.descriptionResumo: Têm-se identificado deficiência de vitaminas em estações de tratamento biológico de efluentes, em especial do ácido fólico, que age como micronutriente para certas bactérias e estimulando seu crescimento. Este trabalho avaliou o efeito de diferentes concentrações de ácido fólico sobre o lodo em condições fisiológicas normais e em respiração endógena. O sistema foi conduzido em batelada a 25ºC±2ºC, vazão de ar de 0,5 L/min e utilizando água residuária sintética, sendo acompanhado a DQO, pH e Sólidos Totais, Sólidos Totais Fixos, Sólidos Totais Voláteis e visualização em microscópio ótico. Os resultados foram comparados ao controle. Os resultados demonstraram que concentrações de 4,0 e 8,0 mg/L de ácido fólico produzem melhora na microfauna do sistema de lodos ativados, sendo que a concentração de 8,0 mg/L ainda foi capaz de aumentar a velocidade de remoção de DQO nas condições fisiológicas normais do lodo e após a respiração endógena. A concentração de 4,0 mg/L apresentou, estatisticamente, resultado semelhante à concentração de 8,0 mg/L para a condição inicial do lodo em respiração endógena, melhorando a velocidade de remoção de DQO. Quanto ao pH e a remoção de DQO não houve alterações provocadas pela adição do ácido fólico, como era esperado
dc.descriptionAbstract: They are deficiency of vitamins in sludge of biological wastewater treatment, especially the folic acid, that acts as micronutrient for certain bacteria and stimulating its growth. This work evaluated the effect of different concentrations of folic acid on the sludge in normal physiologic conditions and in endogenous respiration. The system was carried out batch reactor at 25ºC±2ºC, air flow of 0,5 L/min and using synthetic wastewater, being accompanied COD, pH and Total Solids, Fixed Total Solids, Volatile Total Solids and visualization in optic microscope. The results were compared to the control. The results demonstrated that the concentrations of 4,0 and 8.0 mg/L of folic acid produce improvement in the microfauna of the system of activated sludge, and the concentration of 8,0 mg/L was still capable to increase the speed of removal of COD in the normal physiologic conditions of the sludge and in the endogenous respiration. The concentration of 4,0 mg/L presented similar statistical result to the concentration of 8,0 mg/L for the initial condition of the endogenous respiration sludge, improving the speed COD removal. The pH and the COD removal did not have alterations provoked by the addition of the folic acid
dc.descriptionMestrado
dc.descriptionMestre em Engenharia de Alimentos
dc.format85f. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectRespiração endogena
dc.subjectDigestão aerobia
dc.subjectÁcido fólico DeCS
dc.subjectLodo ativado
dc.subjectFolic acid
dc.subjectActivated sludge
dc.subjectEndogenous respiration
dc.subjectAerobic digestion
dc.titleAvaliação da aplicação de acido folico em tratamento aerobio de aguas residuarias
dc.titleEvaluation of application of folic acid in aerobic wastewater treatment
dc.typeTesis


Este ítem pertenece a la siguiente institución