Use of microbial reactors contaning immobilized cells on the treatment of the wastewater of a beverage industry

dc.creatorCruz, Juliana Gisele Belote D'Arcadia
dc.date2007
dc.date2007-07-23T00:00:00Z
dc.date2017-03-29T13:01:04Z
dc.date2017-07-07T19:20:57Z
dc.date2017-03-29T13:01:04Z
dc.date2017-07-07T19:20:57Z
dc.date.accessioned2018-03-29T03:15:15Z
dc.date.available2018-03-29T03:15:15Z
dc.identifier(Broch.)
dc.identifierCRUZ, Juliana Gisele Belote D'Arcadia. Utilização de reatores microbianos com celulas imobilizadas no tratamento de efluente de uma industria de bebidas. 2007. 79f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=vtls000415195>. Acesso em: 29 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/254753
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1328392
dc.descriptionOrientador: Lucia Regina Durrant
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos
dc.descriptionResumo: O presente estudo avaliou a utilização da tecnologia de tratamento de despejos líquidos de uma indústria cervejeira e de refrigerantes pelo sistema biológico aeróbio. Buscou-se a remoção da carga orgânica mediante quantificação da demanda bioquímica de oxigênio (DBO), demanda química de oxigênio (DQO), nitrogênio amoniacal total, turbidez, sólidos sedimentáveis (SS), fósforo (P), condutividade e toxicidade. O sistema de tratamento proposto foi constituído por quatro reatores em série com volume total de 16 L. A alimentação foi realizada de forma contínua pela parte inferior e por gravidade. Para a imobilização dos microrganismos nos reatores foi utilizado, como suporte, argila expandida. Para o sistema aeróbio foi utilizada aeração prolongada mediante injeção ascendente de oxigênio. As análises foram realizadas diariamente, no afluente do reator e no efluente tratado em diferentes tempos de retenção hidráulica (TRH/h). Os resultados obtidos mostraram que o sistema de tratamento, empregando 4 reatores acoplados, foi eficiente para a remoção da carga orgânica poluente do efluente da indústria. Ocorreu diminuição da DQO em todos os tempos de retenção hidráulica testados. O TRH 1,9 mostrou ser o mais eficiente, visto que é o tempo com a maior vazão, fato de extrema importância para o tratamento de efluentes industriais. Neste TRH houve maior porcentagem de remoção da DBO (67,4%), toxicidade com microcrustáceo Daphinia similis (52,3%), condutividade (13,13%), além de significativa remoção da DQO (58,7%)
dc.descriptionAbstract: The present study the treatment of the waste waters of a beer and soft drink industry by an aerobic biological system was evaluated. The removal of the organic load by means of the quantification of the biochemical oxygen demand (BOD), chemical oxygen demand (COD), total ammoniacal nitrogen, turbidity, sedimented solids (SS), phosphorus (P), conductivity and toxicity. Were determined proposed the consisted of four reactors in series with a total volume of 16 L. The feeding was carried out carried out continuous by through the of the bioreactor inferior part and by gravity. Expanded clay was used as support for the immobilization of the microorganisms in the reactors. Continuous aeration by means of ascending injection of oxygen was used for the aerobic system. The analyses were performed daily in samples from the treated and untreated industrial effluent using different times of hydraulical retention (HRT/h). The results showed that the treatment system, using 4 connected reactors was efficient for the removal of the pollutant organic load of the industrys effluent. Reduction of the COD occurred in all the tested hydraulical retention times used HRT of 1.9 was found to be the most efficient HRT, since it was the time with the hioghest outflow, fact that is of extreme importance for the treatment of industrial effluents. In this HRT there was a greater percentage of reduction of the BOD (67.4%), the toxicity with the Daphinia similis (52.3%) and conductivity (13.13%), besides the significant reduction of the COD (58.7%)
dc.descriptionDoutorado
dc.descriptionDoutor em Ciencia de Alimentos
dc.format79f. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectEfluente industrial
dc.subjectCervejaria
dc.subjectBiofiltro aerobio
dc.subjectCelulas imobilizadas
dc.subjectBioreatores
dc.subjectIndustrial effluent
dc.subjectBrewery
dc.subjectAerobic biofilter
dc.subjectImmobilized cells
dc.subjectBioreactors
dc.titleUtilização de reatores microbianos com celulas imobilizadas no tratamento de efluente de uma industria de bebidas
dc.titleUse of microbial reactors contaning immobilized cells on the treatment of the wastewater of a beverage industry
dc.typeTesis


Este ítem pertenece a la siguiente institución