Evaluation of systematic uncertainties for Monte-Carlo radiation transport code

dc.creatorAguirre Contreras, Eder Humberto, 1989-
dc.date2016
dc.date2016-04-03T00:00:00Z
dc.date2017-04-03T04:19:37Z
dc.date2017-06-14T17:34:47Z
dc.date2017-04-03T04:19:37Z
dc.date2017-06-14T17:34:47Z
dc.date.accessioned2018-03-29T02:45:24Z
dc.date.available2018-03-29T02:45:24Z
dc.identifierAGUIRRE CONTRERAS, Eder Humberto. Avaliação das incertezas sistemáticas em simulações Monte Carlo do transporte de radiação. 2016. 1 recurso online (62 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=000964858&opt=4>. Acesso em: 3 abr. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/276901
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1320852
dc.descriptionOrientador: Mario Antonio Bernal Rodriguez
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin
dc.descriptionResumo: Este trabalho estuda o impacto das incertezas sistemáticas associadas às seções de choque nas curvas de dose em profundidade determinadas por simulações Monte Carlo. Os fatores de sensibilidade dose.vs.seção de choque são quantificados alterando as seções de choque em uma dada quantidade e por determinação da variação da dose. A influência das seções de choque totais para todas as partículas (elétrons, pósitrons e fótons) e para os 4 processos principais de interações dos fótons é abordada. O código PENELOPE foi utilizado em todas as simulações. Verificou-se que os fatores de sensibilidade das seções de choque dos fótons dependem da profundidade. Além disso, eles são positivo e negativo para profundidades abaixo e acima de uma profundidade de equilíbrio, respectivamente. Nesta profundidade, os fatores de sensibilidade são nulos. As profundidades de equilíbrio encontradas neste trabalho concordam com o caminho livre médio para a energia do fóton incidente correspondente. Utilizando os fatores de sensibilidade aqui relatados, é possível estimar o impacto da incerteza da seção de choque total das interações: Compton, Rayleigh e fotoefeito, na incerteza das curvas de dose em profundidade determinados por Monte Carlo
dc.descriptionAbstract: This work studies the impact of systematic uncertainties associated to interaction cross sections on depth dose curves determined by Monte Carlo simulations. The corresponding sensitivity factors are quantified by changing cross sections in a given amount and determining the variation in the dose. The influence of total cross sections for all particles (electrons, positrons and photons) and the 4 main processes of interaction of photons are addressed. The PENELOPE code was used in all simulations. It was found that photon cross section sensitivity factors depend on depth. In addition, they are positive and negative for depths below and above an equilibrium depth, respectively. At this depth, sensitivity factors are null. The equilibrium depths found in this work agree very well with the mean free path of the corresponding incident photon energy. Using the sensitivity factors reported here, it is possible to estimate the impact of the Compton, Rayleigh and photoelectric effect cross section uncertainty on the uncertainty of Monte Carlo-determined depth dose curves
dc.descriptionMestrado
dc.descriptionFísica
dc.descriptionMestre em Física
dc.description1370426/2014
dc.descriptionCAPES
dc.format1 recurso online (62 p.) : il., digital, arquivo PDF.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.relationRequisitos do sistema: Software para leitura de arquivo em PDF
dc.subjectMonte Carlo, Método de
dc.subjectIncerteza (Teoria da informação)
dc.subjectFeixes de fótons
dc.subjectMonte Carlo method
dc.subjectUncertainty (Information theory)
dc.subjectPhoton beams
dc.titleAvaliação das incertezas sistemáticas em simulações Monte Carlo do transporte de radiação
dc.titleEvaluation of systematic uncertainties for Monte-Carlo radiation transport code
dc.typeTesis


Este ítem pertenece a la siguiente institución