Proposition and evaluation of a method for tridimensional kinematic analysis of the patellofemoral joint based on external markers

dc.creatorSobral, Juliana Moreno Carmona, 1987
dc.date2014
dc.date2017-04-02T11:03:48Z
dc.date2017-06-08T12:34:35Z
dc.date2017-04-02T11:03:48Z
dc.date2017-06-08T12:34:35Z
dc.date.accessioned2018-03-29T02:10:57Z
dc.date.available2018-03-29T02:10:57Z
dc.identifierSOBRAL, Juliana Moreno Carmona. Proposição e avaliação de um método para análise cinemática tridimensional da articulação femoropatelar a partir de marcadores externos. 2014. 55 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Física, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=000938953>. Acesso em: 2 abr. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/275060
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1312030
dc.descriptionOrientador: Ricardo Machado Leite de Barros
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Física
dc.descriptionResumo: O objetivo geral do trabalho foi propor e avaliar um método para análise cinemática tridimensional da articulação femoropatelar a partir de marcadores externos, durante a execução de saltos verticais. Para isso, foi desenvolvida uma configuração específica do sistema de análise, com seis câmeras industriais posicionadas de forma a garantir um bom valor de exatidão da medida gerada. A frequência de aquisição foi 100 Hz. O rastreamento dos segmentos corporais analisados e a reconstrução das respectivas coordenadas 3D foram realizados no software Dvideo. Já a orientação e modelagem foram feitas no software Visual 3D®. Neste estudo foram avaliados doze sujeitos saudáveis (grupo controle) e cinco sujeitos com síndrome femoropatelar em ambos os joelhos (grupo SFP). As variáveis analisadas foram a exatidão da medida do sistema, a distância entre os marcadores da patela, os ângulos de rotação do joelho e os ângulos de rotação e translação da articulação femoropatelar. A análise dos resultados foi feita após subdividir o movimento do salto em função do ângulo de flexão do joelho, em duas fases distintas, a decolagem (agachamento e impulsão) e a aterrissagem (aterrissagem e retorno à posição inicial). Os ângulos de rotação e valores de translação obtidos foram similares para os membros inferiores para as duas articulações analisadas. Já em relação às fases do movimento, todos os valores apresentaram menor magnitude na aterrissagem, uma vez que a amplitude de movimento de flexão do joelho nesta fase foi menor. Durante o agachamento, ambos os grupos apresentaram flexão, deslocamento medial, posterior e inferior da AFP, porém em menor amplitude no grupo SFP. A análise de confiabilidade apresentou valores de concordância excelente, sugerindo que o método utilizado gere dados consistentes. Podemos concluir que o modelo proposto foi capaz de detectar movimentação da patela em relação ao fêmur no eixo transversal para a rotação e nos eixos transversal, ântero-posterior e longitudinal para translação, em ambos os grupos estudados
dc.descriptionAbstract: The major aim of this study was to propose and evaluate a method for three-dimensional kinematic analysis of the patellofemoral joint based on external markers while performing vertical jumps. For this, a specific configuration of the analysis system was developed, with six industrial cameras positioned to ensure a good accuracy of the measurement data. The acquisition frequency was 100 Hz. The analyzed body segments tracking and the reconstruction of their 3D coordinates were performed in Dvideo software. Their orientation and modeling were done in Visual 3D ® software. In this study we evaluated twelve healthy subjects (control group) and five subjects with patellofemoral syndrome in both knees (SFP group). The analyzed variables were the accuracy of the system, the distance between the markers of the patella, knee and patellofemoral rotation angles and translation values of the patellofemoral joint. The data analysis was made after subdividing the jump movement according to the angle of knee flexion in two distinct phases, takeoff (squat and propulsion) and landing (landing and return to starting position). The knee and patellofemoral obtained rotation angles and translation values were similar for both lower limbs. In relation to the vertical jump phases, all values were lower in the landing phase, due to the knee range of motion at this stage has been equally lower. During the squat, both groups showed flexion, medial, posterior and inferior displacement of the patellofemoral joint, but the SFP group showed smaller values. The reliability analysis showed excellent agreement values, suggesting that the method used in this study is capable to generate consistent data. We can conclude that the proposed model was able to detect patellar movement relative to the femur in the transverse axis for the rotation and in the transverse, anteroposterior and longitudinal axes for translation, in both groups
dc.descriptionMestrado
dc.descriptionBiodinamica do Movimento e Esporte
dc.descriptionMestra em Educação Física
dc.format55 f. : il.
dc.formatapplication/pdf
dc.publisher[s.n.]
dc.subjectCinemática
dc.subjectArticulação Patelofemoral
dc.subjectMetodologia
dc.subjectKinematics
dc.subjectPatellofemoral joint
dc.subjectMethodology
dc.titleProposição e avaliação de um método para análise cinemática tridimensional da articulação femoropatelar a partir de marcadores externos
dc.titleProposition and evaluation of a method for tridimensional kinematic analysis of the patellofemoral joint based on external markers
dc.typeTesis


Este ítem pertenece a la siguiente institución