dc.creator | LEGENDRE, Daniel | |
dc.creator | ANTUNES, Pedro | |
dc.creator | BOCK, Eduardo | |
dc.creator | ANDRADE, Aron | |
dc.creator | BISCEGLI, Jose F. | |
dc.creator | ORTIZ, Jayme Pinto | |
dc.date | 2008 | |
dc.date | 2013-09-18T13:20:18Z | |
dc.date | 2016-06-30T13:03:32Z | |
dc.date | 2013-09-18T13:20:18Z | |
dc.date | 2016-06-30T13:03:32Z | |
dc.date.accessioned | 2018-03-29T01:52:48Z | |
dc.date.available | 2018-03-29T01:52:48Z | |
dc.identifier | ARTIFICIAL ORGANS, v.32, n.4, p.342-348, 2008 | |
dc.identifier | 0160-564X | |
dc.identifier | 10.1111/j.1525-1594.2008.00552.x | |
dc.identifier | http://dx.doi.org/10.1111/j.1525-1594.2008.00552.x | |
dc.identifier | http://apps.isiknowledge.com/InboundService.do?Func=Frame&product=WOS&action=retrieve&SrcApp=EndNote&UT=000254412900015&Init=Yes&SrcAuth=ResearchSoft&mode=FullRecord | |
dc.identifier | http://www.repositorio.unicamp.br/jspui/handle/REPOSIP/1707 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/1707 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1308249 | |
dc.description | In the development of a ventricular assist device, computational fluid dynamics (CFD) analysis is an efficient tool to obtain the best design before making the final prototype. In this study, different designs of a centrifugal blood pump were developed to investigate flow characteristics and performance. This study assumed the blood flow as being an incompressible homogeneous Newtonian fluid. A constant velocity was applied at the inlet; no slip boundary conditions were applied at device wall; and pressure boundary conditions were applied at the outlet. The CFD code used in this work was based on the finite volume method. In the future, the results of CFD analysis can be compared with flow visualization and hemolysis tests. | |
dc.description | 32 | |
dc.description | 4 | |
dc.description | 342 | |
dc.description | 348 | |
dc.language | eng | |
dc.publisher | BLACKWELL PUBLISHING | |
dc.publisher | Inglaterra | |
dc.relation | Artificial Organs | |
dc.relation | 4th Latin American Congress for Artificial Organs and Biomaterials; Caxambu, BRAZIL; AUG 08-11, 2006 | |
dc.rights | fechado | |
dc.rights | Copyright BLACKWELL PUBLISHING | |
dc.source | WOS | |
dc.subject | centrifugal blood pump | |
dc.subject | hemodynamic | |
dc.subject | numerical simulation | |
dc.subject | wall shear stress | |
dc.subject | FLOW VISUALIZATION | |
dc.subject | SPIRAL PUMP | |
dc.subject | DAMAGE | |
dc.subject | Engineering, Biomedical | |
dc.subject | Transplantation | |
dc.title | Computational fluid dynamics investigation of a centrifugal blood pump | |
dc.type | Artículos de revistas | |
dc.type | Actas de congresos | |
dc.type | Artículos de revistas | |