dc.creatorLEGENDRE, Daniel
dc.creatorANTUNES, Pedro
dc.creatorBOCK, Eduardo
dc.creatorANDRADE, Aron
dc.creatorBISCEGLI, Jose F.
dc.creatorORTIZ, Jayme Pinto
dc.date2008
dc.date2013-09-18T13:20:18Z
dc.date2016-06-30T13:03:32Z
dc.date2013-09-18T13:20:18Z
dc.date2016-06-30T13:03:32Z
dc.date.accessioned2018-03-29T01:52:48Z
dc.date.available2018-03-29T01:52:48Z
dc.identifierARTIFICIAL ORGANS, v.32, n.4, p.342-348, 2008
dc.identifier0160-564X
dc.identifier10.1111/j.1525-1594.2008.00552.x
dc.identifierhttp://dx.doi.org/10.1111/j.1525-1594.2008.00552.x
dc.identifierhttp://apps.isiknowledge.com/InboundService.do?Func=Frame&product=WOS&action=retrieve&SrcApp=EndNote&UT=000254412900015&Init=Yes&SrcAuth=ResearchSoft&mode=FullRecord
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/1707
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/1707
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1308249
dc.descriptionIn the development of a ventricular assist device, computational fluid dynamics (CFD) analysis is an efficient tool to obtain the best design before making the final prototype. In this study, different designs of a centrifugal blood pump were developed to investigate flow characteristics and performance. This study assumed the blood flow as being an incompressible homogeneous Newtonian fluid. A constant velocity was applied at the inlet; no slip boundary conditions were applied at device wall; and pressure boundary conditions were applied at the outlet. The CFD code used in this work was based on the finite volume method. In the future, the results of CFD analysis can be compared with flow visualization and hemolysis tests.
dc.description32
dc.description4
dc.description342
dc.description348
dc.languageeng
dc.publisherBLACKWELL PUBLISHING
dc.publisherInglaterra
dc.relationArtificial Organs
dc.relation4th Latin American Congress for Artificial Organs and Biomaterials; Caxambu, BRAZIL; AUG 08-11, 2006
dc.rightsfechado
dc.rightsCopyright BLACKWELL PUBLISHING
dc.sourceWOS
dc.subjectcentrifugal blood pump
dc.subjecthemodynamic
dc.subjectnumerical simulation
dc.subjectwall shear stress
dc.subjectFLOW VISUALIZATION
dc.subjectSPIRAL PUMP
dc.subjectDAMAGE
dc.subjectEngineering, Biomedical
dc.subjectTransplantation
dc.titleComputational fluid dynamics investigation of a centrifugal blood pump
dc.typeArtículos de revistas
dc.typeActas de congresos
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución