dc.creatorOshita
dc.creatorDaniele; Jardim
dc.creatorIsabel C. S. F.
dc.date2015-DEC
dc.date2016-06-07T13:35:29Z
dc.date2016-06-07T13:35:29Z
dc.date.accessioned2018-03-29T01:51:02Z
dc.date.available2018-03-29T01:51:02Z
dc.identifier
dc.identifierComparison Of Methods By Liquid Chromatography For The Determination Of Pesticide Multiresidues In Strawberries. Soc Brasileira Quimica, v. 38, p. 1273-1281 DEC-2015.
dc.identifier0100-4042
dc.identifierWOS:000367255200004
dc.identifier10.5935/0100-4042.20150145
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015001001273&lng=en&nrm=iso&tlng=en
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/244143
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1307841
dc.descriptionLiquid chromatography is often used for the determination of pesticide multiresidues in foods. In Brazil, the strawberry crop is an example of a food with high levels of irregularities because of the application of pesticides. This is a major concern from the perspective of food safety, environmental protection, and certification for food export. The purpose of this study is to evaluate and compare chromatographic separation and detection methods in relation to a newly developed and validated method using ultra high performance liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS) for the analytical determination of pesticides in strawberries. The comparisons were based on evaluations of the analysis time, consumption of the solvent in the mobile phase, injection volume, detectability, matrix effect, and recovery. The results showed that the LC-MS/MS and UHPLC-MS/MS techniques were both extremely efficient at analyzing pesticide residues with different physico-chemical parameters that were present at low concentrations in a complex matrix. The UHPLC separation method provided better chromatographic performance and productivity, which contributed favorably to routine analytical determinations. Detection by MS/MS had better detectability and selectivity compared with the diode array detector.
dc.description38
dc.description10
dc.description
dc.description1273
dc.description1281
dc.description
dc.description
dc.description
dc.languagept
dc.publisherSOC BRASILEIRA QUIMICA
dc.publisher
dc.publisherSAO PAULO
dc.relationQUIMICA NOVA
dc.rightsfechado
dc.sourceWOS
dc.subjectTandem Mass-spectrometry
dc.subjectResidue Analysis
dc.subjectQuechers Method
dc.subjectUplc-ms/ms
dc.subjectFood
dc.subjectPerformance
dc.subjectVegetables
dc.subjectFruits
dc.subjectConsumption
dc.subjectEnvironment
dc.titleComparison Of Methods By Liquid Chromatography For The Determination Of Pesticide Multiresidues In Strawberries
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución