dc.creatorGiannini, Marcelo
dc.creatorLiberti, Michele Santana
dc.creatorArrais, César Augusto Galvão
dc.creatorReis, André Figueiredo
dc.creatorMettenburg, Donald
dc.creatorRueggeberg, Frederick Allen
dc.date2012-Dec
dc.date2015-11-27T13:29:15Z
dc.date2015-11-27T13:29:15Z
dc.date.accessioned2018-03-29T01:16:50Z
dc.date.available2018-03-29T01:16:50Z
dc.identifierActa Odontologica Scandinavica. v. 70, n. 6, p. 478-84, 2012-Dec.
dc.identifier1502-3850
dc.identifier10.3109/00016357.2011.639308
dc.identifierhttp://www.ncbi.nlm.nih.gov/pubmed/22150012
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/200389
dc.identifier22150012
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1300622
dc.descriptionThis study evaluated the effects of filler addition, storage medium and time on biaxial flexural strength and flexural modulus of six adhesive systems. The adhesives were either unfilled resins: Single Bond, Prime&Bond 2.1 and One-Step; or filled resins: Single Bond Plus, Prime&Bond NT and One-Step Plus. Resin discs of each product (0.5 mm thick × 6.0 mm diameter) were prepared using silicon molds (n = 10). The discs were stored dry, in water, mineral oil or ethanol for 1 week or 3 months before biaxial flexural testing. Data were statistically analyzed by 3-way ANOVA and Tukey's post-hoc test (α = 0.05). The specimens were tested in a universal testing machine at 1.27 mm/min until failure occurred. In general, the storage in ethanol led to significantly lower flexural strength and flexural modulus values than the other storage conditions for all adhesives in both storage periods. Filler addition increased flexural strength and flexural modulus for Prime&Bond NT, when it was stored dry or in water for 1 week. For Single Bond Plus, the filler addition resulted in higher flexural modulus, when it was stored for 1 week in oil and in ethanol. No significant differences in flexural modulus were observed between One-Step and One-Step Plus in any storage medium. Results suggested that filler addition does not necessarily have to increase the flexural strength and flexural modulus. Ethanol and oil storages tended to yield opposite effects.
dc.description70
dc.description478-84
dc.languageeng
dc.relationActa Odontologica Scandinavica
dc.relationActa Odontol. Scand.
dc.rightsfechado
dc.rights
dc.sourcePubMed
dc.subjectAnalysis Of Variance
dc.subjectDental Cements
dc.subjectMaterials Testing
dc.titleInfluence Of Filler Addition, Storage Medium And Evaluation Time On Biaxial Flexure Strength And Modulus Of Adhesive Systems.
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución