dc.description | The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74 degrees C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (alpha= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins. | |
dc.description | 20 | |
dc.description | 132-7 | |
dc.language | eng | |
dc.relation | Brazilian Dental Journal | |
dc.relation | Braz Dent J | |
dc.rights | fechado | |
dc.rights | | |
dc.source | PubMed | |
dc.subject | Acrylic Resins | |
dc.subject | Dental Stress Analysis | |
dc.subject | Denture Bases | |
dc.subject | Disinfection | |
dc.subject | Hardness | |
dc.subject | Microwaves | |
dc.subject | Pliability | |
dc.title | Effect Of Repeated Disinfections By Microwave Energy On The Physical And Mechanical Properties Of Denture Base Acrylic Resins. | |
dc.type | Artículos de revistas | |