dc.creatorMazzonetto, R
dc.creatorPaza, A O
dc.creatorSpagnoli, D B
dc.date2004-Oct
dc.date2015-11-27T12:58:25Z
dc.date2015-11-27T12:58:25Z
dc.date.accessioned2018-03-29T00:59:33Z
dc.date.available2018-03-29T00:59:33Z
dc.identifierInternational Journal Of Oral And Maxillofacial Surgery. v. 33, n. 7, p. 664-9, 2004-Oct.
dc.identifier0901-5027
dc.identifier10.1016/j.ijom.2004.02.001
dc.identifierhttp://www.ncbi.nlm.nih.gov/pubmed/15337179
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/195934
dc.identifier15337179
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1296167
dc.descriptionThis study was designed to evaluate clinical and radiological evidence of osteotomy site healing in orthognathic surgery after rigid fixation using a biodegradable plating system. A follow up of 30 patients who underwent orthognathic surgery using a biodegradable self-reinforced (70L:30DL) polylactide plating system was presented. The follow-up schedule for all patients consisted of regular appointments at 1-180 days after surgery. Clinical evaluation involved notation of any abnormal swelling, infection, discoloration, or discharge at the osteotomy sites. Stability was evaluated by manual palpation. For radiographic evaluation, panoramic radiographs were taken immediately after surgery, and again at 7-180 days. The radiographs were analyzed for any visual changes in osteotomy fragments, resorptive changes in osteotomy fragments, callus formation, and union of the osteotomy segments. No clinical complications and no radiological changes in the osteotomy sites were observed. Regarding the clinical usefulness of the biodegradable fixation system, fixation at the time of operation was considered as excellent in all 30 cases. The conclusions of this study were that self-reinforced (70L:30DL) polylactide was considered to be comparable to other forms of rigid internal fixation for orthognathic surgery.
dc.description33
dc.description664-9
dc.languageeng
dc.relationInternational Journal Of Oral And Maxillofacial Surgery
dc.relationInt J Oral Maxillofac Surg
dc.rightsfechado
dc.rights
dc.sourcePubMed
dc.subjectAbsorbable Implants
dc.subjectBone Plates
dc.subjectBone Screws
dc.subjectHumans
dc.subjectJaw Fixation Techniques
dc.subjectMandibular Advancement
dc.subjectOsteotomy, Le Fort
dc.subjectPolyesters
dc.subjectRetrospective Studies
dc.titleA Retrospective Evaluation Of Rigid Fixation In Orthognathic Surgery Using A Biodegradable Self-reinforced (70l:30dl) Polylactide.
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución