dc.descriptionIn liquid-liquid extraction performed by monosegmented flow analysis (MSFA), the aqueous sample is introduced between two air bubbles and flows, under restricted dispersion, through a glass extraction tube where the analyte is retained, usually at pH higher than 8. The retained analyte is removed to a small volume of an organic phase containing a ligand which is introduced after the second air bubble. In this work, the effect of the organic phase composition on the extraction of Cu(II), Zn(II) and Cd(II) in MSFA systems was investigated by changing the ethanol content (0.1-4% v/v) in toluene, chloroform and carbon tetrachloride, The extracting efficiency of the organic phases containing ethanol was evaluated by using dithizone (DT), 1-2-pyridylazo-2 naphthol (PAN) and sodium diethyldithiocarbamate (DDTC) as ligands for the metals. The MSFA extraction system was improved by introducing a new syringe-based device for organic phase delivery. The presence of ethanol in the organic phase shows a remarkable (up to ten times) effect on the extraction efficiency of the flow system when DT is employed. Its presence is mandatory if DDTC is used, as it accounts for ligand solubility in the organic phase. The extraction efficiency also increases with the pH of the aqueous phase as a consequence of higher ionisation of the glass silanols, where the analytes are adsorbed before extraction. The system has been evaluated for determination of Zn(II) in drugs showing a mean R.S.D. of 2.2% and mean relative accuracy of 4.4%, when compared with atomic absorption spectrometry results. Typical sample frequency, sample and organic phase consumption are 30 samples per hour, 200 and 100 mul, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
dc.description56
dc.description4
dc.description643
dc.description653
dc.languageen
dc.publisherElsevier Science Bv
dc.publisherAmsterdam
dc.publisherHolanda
dc.relationTalanta
dc.relationTalanta
dc.rightsfechado
dc.rightshttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dc.sourceWeb of Science
dc.subjectmonosegmented flow analysis
dc.subjectliquid-liquid extraction
dc.subjectzinc determination
dc.subjecteffect of ethanol
dc.subjectInjection Analysis
dc.subjectSpectrophotometric Determination
dc.subjectSolvent-extraction
dc.subjectSequential-injection
dc.subjectAnionic Surfactants
dc.subjectPlant-material
dc.subjectSystem
dc.subjectSegmentation
dc.subjectPhosphorus
dc.titleEffect of ethanol in the organic phase on liquid-liquid extraction in monosegmented flow analysis. Determination of zinc in drugs