dc.creatorPASQUINI, C
dc.creatorCUNHA, IBS
dc.date1995
dc.dateNOV
dc.date2014-12-16T11:34:06Z
dc.date2015-11-26T17:57:28Z
dc.date2014-12-16T11:34:06Z
dc.date2015-11-26T17:57:28Z
dc.date.accessioned2018-03-29T00:41:01Z
dc.date.available2018-03-29T00:41:01Z
dc.identifierAnalyst. Royal Soc Chemistry, v. 120, n. 11, n. 2763, n. 2767, 1995.
dc.identifier0003-2654
dc.identifierWOS:A1995TE86100019
dc.identifier10.1039/an9952002763
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/55207
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/55207
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/55207
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1291491
dc.descriptionThe high-performance microcomputer controlled gravimetric-burette described in Part 1 has been employed to automate some routine analytical procedures, A direct potentiometric determination of fluoride ions in drinking water was developed to include an automatic calibration step, matrix adjustment and sample determination. Also the complex and cumbersome titrimetric procedure far determination of the kappa number (lignin content) in paper pulp, has been automated by using the gravimetric unit and biamperometry, In this last instance, the,automatic standardization of the solutions employed in the determination and the complete automation of the recommended kappa number determination procedure, allows a significant reduction in the amount of reagent consumed. The gravimetric approach to these procedures reveals that the same performance is achieved in terms of precision and accuracy when compared with classic volumetry while the cost associated with the automation decreases owing to the use of the same unit to attain automatic management of up to three different solutions.
dc.description120
dc.description11
dc.description2763
dc.description2767
dc.languageen
dc.publisherRoyal Soc Chemistry
dc.publisherCambridge
dc.publisherInglaterra
dc.relationAnalyst
dc.relationAnalyst
dc.rightsaberto
dc.sourceWeb of Science
dc.subjectAUTOMATED GRAVIMETRIC BURET
dc.subjectFLUORIDE DETERMINATION IN DRINKING WATER
dc.subjectKAPPA NUMBER OF PAPER PULP
dc.subjectAUTOMATION OF BIAMPEROMETRIC TITRATIONS
dc.subjectDIRECT POTENTIOMETRY
dc.subjectElectrode
dc.subjectFluoride
dc.titleAUTOMATED GRAVIMETRIC MANAGEMENT OF SOLUTIONS .2. AUTOMATED GRAVIMETRIC APPROACH TO DIRECT POTENTIOMETRY AND KAPPA NUMBER DETERMINATION
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución