dc.creatorMaschio, C
dc.creatorde Arruda, ACF
dc.date2002
dc.dateJAN
dc.date2014-07-30T19:07:34Z
dc.date2015-11-26T17:50:48Z
dc.date2014-07-30T19:07:34Z
dc.date2015-11-26T17:50:48Z
dc.date.accessioned2018-03-29T00:34:06Z
dc.date.available2018-03-29T00:34:06Z
dc.identifierJournal Of Testing And Evaluation. Amer Soc Testing Materials, v. 30, n. 1, n. 85, n. 88, 2002.
dc.identifier0090-3973
dc.identifierWOS:000173711800010
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/73079
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/73079
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1289794
dc.descriptionCartridge filter manufacturers conventionally use air permeability, and bubble point tests for the evaluation of integrity and filtration rating of their filter elements. These tests reveal information only upstream and downstream of the filters. If a region of low density and a region of high density (compared to the mean density of the filter) exist in the interior of the element, these two regions may be superimposed and the results of the test may cause acceptance of an imperfect filter. The present paper shows the use of an X-ray computerized tomography scanner for visualization of internal defects in the cartridge filter elements used in industrial and domestic applications. Tomographic images with good contrast were obtained. The images clearly revealed cracks in the activated carbon filter and regions of high density in the fibrous filter (melt-blown type). Finally, the main objective of this paper is to show that X-ray computerized tomography can be used successfully within the filter industries as a potential tool in the evaluation of existing products, and as a support in new product development.
dc.description30
dc.description1
dc.description85
dc.description88
dc.languageen
dc.publisherAmer Soc Testing Materials
dc.publisherW Conshohocken
dc.publisherEUA
dc.relationJournal Of Testing And Evaluation
dc.relationJ. Test. Eval.
dc.rightsfechado
dc.sourceWeb of Science
dc.subjectX-ray computerized tomography
dc.subjectcartridge filters
dc.subjectair permeability testing
dc.subjectbubble point testing
dc.subjectdefects characterization
dc.titleUsing X-ray computerized tomography for characterization of defects in cartridge filters
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución