dc.creatorCorilo, YE
dc.creatorVaz, BG
dc.creatorSimas, RC
dc.creatorNascimento, HDL
dc.creatorKlitzke, CF
dc.creatorPereira, RCL
dc.creatorBastos, WL
dc.creatorNeto, EVS
dc.creatorRodgers, RP
dc.creatorEberlin, MN
dc.date2010
dc.dateMAY 15
dc.date2014-11-16T01:31:23Z
dc.date2015-11-26T17:37:06Z
dc.date2014-11-16T01:31:23Z
dc.date2015-11-26T17:37:06Z
dc.date.accessioned2018-03-29T00:18:47Z
dc.date.available2018-03-29T00:18:47Z
dc.identifierAnalytical Chemistry. Amer Chemical Soc, v. 82, n. 10, n. 3990, n. 3996, 2010.
dc.identifier0003-2700
dc.identifierWOS:000277531500006
dc.identifier10.1021/ac100673v
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/59385
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/59385
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/59385
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1285875
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.descriptionAn ambient ionization/desorption technique, namely, easy ambient sonic-spray ionization mass spectrometry (EASI), has been applied to crude oil samples. From a single droplet of the sample placed on an inert surface, EASI(+/-) is shown to promote efficient desorption and ionization of a myriad of polar components via the action of its cloud of very minute supersonic bipolar charged droplets. The gaseous [M + H](+) and [M - H](-) ions concurrently formed by EASI(+/-) were analyzed by Fourier transform mass spectrometry (FT-ICR MS), and a total of similar to 6000 acidic and basic components have been attributed. EASI(+/-) FT-ICR MS of crude oils is show to be almost as fast as ESI(+)/ESI(-) FT-ICR MS, providing similar compositional information of polar components and spectral quality comparable to that of a commercial nonochip-based robotic ESI device. EASI(+/-) requires no sample workup thus eliminating risks of contamination during sample manipulation and memory effects because of carry over in pumping ESI lines. More importantly, EASI(+/-) is a voltage-free ionization technique therefore eliminating risks of redox processes or duality of ionization mechanisms that can be observed in voltage-assisted processes. Data visualization via typical petroleomic plots confirms the similarity of the compositional information provided by EASI(+/-) compared to ESI(+)/ESI(-). The ambient EASI(+/-) FT-ICR MS method requires no voltage switching in changing the ion polarity mode, offering a workup, heating and voltage-free protocol for petroleomic studies performed at open atmosphere directly on the undisturbed crude oil sample.
dc.description82
dc.description10
dc.description3990
dc.description3996
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.descriptionFINEP
dc.descriptionPetroleo Brasileiro S/A (PETRO-BRAS)
dc.descriptionBrazilian National Petroleum Agency (ANP)
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.languageen
dc.publisherAmer Chemical Soc
dc.publisherWashington
dc.publisherEUA
dc.relationAnalytical Chemistry
dc.relationAnal. Chem.
dc.rightsfechado
dc.sourceWeb of Science
dc.subjectIonization Mass-spectrometry
dc.subjectSonic-spray Ionization
dc.subjectDesorption Electrospray-ionization
dc.subjectAtmospheric-pressure
dc.subjectResonance
dc.subjectHydrocarbons
dc.subjectSamples
dc.subjectSolids
dc.subjectOil
dc.titlePetroleomics by EASI(+/-) FT-ICR MS
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución