dc.creatorde Castro, ARB
dc.creatorMoller, T
dc.date2005
dc.date44348
dc.date2014-11-15T17:52:58Z
dc.date2015-11-26T17:21:07Z
dc.date2014-11-15T17:52:58Z
dc.date2015-11-26T17:21:07Z
dc.date.accessioned2018-03-29T00:08:39Z
dc.date.available2018-03-29T00:08:39Z
dc.identifierNuclear Instruments & Methods In Physics Research Section A-accelerators Spectrometers Detectors And Associated Equipment. Elsevier Science Bv, v. 545, n. 3, n. 568, n. 577, 2005.
dc.identifier0168-9002
dc.identifierWOS:000230268000005
dc.identifier10.1016/j.nima.2005.02.021
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/69529
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/69529
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/69529
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1283291
dc.descriptionWe discuss strategies for color separation and recombination, regarding 2-color pump-and-probe experiments planned for the DESY XUV FEL Phase 2. We show that efficient handling of the pump and probe components, with good spectral and spatial separation, is possible with either filters or gratings; the former are cheap while the latter are continuously tunable over a range. Nice spatial overlap of the pump and probe on a spot 5 x 8 mu m(2) FWHM, limited by surface slope errors on the optics, can be achieved with a Kirkpatrick-Baez pair of cylindrical elliptic mirrors placed about 500 mm away from the sample position. Thermal loading is also discussed. It is found that the filters cannot survive more than a few dozen FEL pulses in a train, while a grating on a water-cooled silicon thin blade will present unacceptable surface slope errors after about 1800 FEL pulses on a train. (c) 2005 Elsevier B.V. All rights reserved.
dc.description545
dc.description3
dc.description568
dc.description577
dc.languageen
dc.publisherElsevier Science Bv
dc.publisherAmsterdam
dc.publisherHolanda
dc.relationNuclear Instruments & Methods In Physics Research Section A-accelerators Spectrometers Detectors And Associated Equipment
dc.relationNucl. Instrum. Methods Phys. Res. Sect. A-Accel. Spectrom. Dect. Assoc. Equip.
dc.rightsfechado
dc.rightshttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dc.sourceWeb of Science
dc.subjectXUV free-electron-laser
dc.subjectpump-and-probe
dc.subjectXUV optics
dc.subjectthermal load
dc.titleOptical configurations for pump and probe experiments with a VUV free-electron laser
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución