dc.creator | Vieira, JCM | |
dc.creator | Freitas, W | |
dc.creator | Xu, WS | |
dc.creator | Morelato, A | |
dc.date | 2006 | |
dc.date | OCT | |
dc.date | 2014-11-17T09:02:37Z | |
dc.date | 2015-11-26T17:19:00Z | |
dc.date | 2014-11-17T09:02:37Z | |
dc.date | 2015-11-26T17:19:00Z | |
dc.date.accessioned | 2018-03-29T00:06:41Z | |
dc.date.available | 2018-03-29T00:06:41Z | |
dc.identifier | Ieee Transactions On Power Delivery. Ieee-inst Electrical Electronics Engineers Inc, v. 21, n. 4, n. 1878, n. 1884, 2006. | |
dc.identifier | 0885-8977 | |
dc.identifier | WOS:000241049900016 | |
dc.identifier | 10.1109/TPWRD.2006.881588 | |
dc.identifier | http://www.repositorio.unicamp.br/jspui/handle/REPOSIP/79943 | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/79943 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/79943 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1282795 | |
dc.description | This paper proposes a method for determining the coordination of the rate of change of frequency (ROCOF) and under/overfrequency relays for distributed generation protection considering islanding detection and frequency-tripping requirements. The method is based on the concept of application region, which defines a region in the trigger time versus active power imbalance space where frequency-based relays can be adjusted to satisfy the anti-islanding and frequency-tripping requirements simultaneously. This method can be used to optimally determine the instantaneous and time-delay settings of different frequency-based relays in a unified, manner. The application region can be also employed to evaluate how much an existing frequency-based protection scheme violates one of the above-mentioned requirements. In addition, it can be used to set different combinations of frequency-based relays in order to make the distributed generator frequency-based protection system as efficient as possible, since it respects the region that satisfies both requirements. | |
dc.description | 21 | |
dc.description | 4 | |
dc.description | 1878 | |
dc.description | 1884 | |
dc.language | en | |
dc.publisher | Ieee-inst Electrical Electronics Engineers Inc | |
dc.publisher | Piscataway | |
dc.publisher | EUA | |
dc.relation | Ieee Transactions On Power Delivery | |
dc.relation | IEEE Trans. Power Deliv. | |
dc.rights | fechado | |
dc.rights | http://www.ieee.org/publications_standards/publications/rights/rights_policies.html | |
dc.source | Web of Science | |
dc.subject | distributed generation | |
dc.subject | dynamic simulation | |
dc.subject | frequency relays | |
dc.subject | islanding detection | |
dc.subject | rate of change of frequency relays | |
dc.subject | synchronous generators | |
dc.title | Efficient coordination of ROCOF and frequency relays for distributed generation protection by using the application region | |
dc.type | Artículos de revistas | |