dc.creatorPetrucelli, GA
dc.creatorPoppi, RJ
dc.creatorMincato, RL
dc.creatorPereira-Filho, ER
dc.date2007
dc.dateFEB 15
dc.date2014-11-14T07:17:27Z
dc.date2015-11-26T17:13:45Z
dc.date2014-11-14T07:17:27Z
dc.date2015-11-26T17:13:45Z
dc.date.accessioned2018-03-29T00:02:06Z
dc.date.available2018-03-29T00:02:06Z
dc.identifierTalanta. Elsevier Science Bv, v. 71, n. 2, n. 620, n. 626, 2007.
dc.identifier0039-9140
dc.identifierWOS:000244369600017
dc.identifier10.1016/j.talanta.2006.05.008
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/77047
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/77047
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/77047
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1281647
dc.descriptionThis work describes a methodology for Cd and Pb determination in sewage sludge slurry samples using thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS). The TS-FF-AAS system was equipped with a Ni tube atomizer placed on an oxidizing air/acetylene flame. Two multivariate calibration models based on partial least squares (PLS) were proposed using total peak profiles (recorded during 57 s). Metals concentration in the sewage sludge samples were from 1.87 to 6.26 mg kg(-1) for Cd and from 101 to 327 mg kg(-1) for Ph. The limits of detection and quantification were, respectively, 0.2 and 0.7 mu g kg(-1) for Cd and 8 and 26 mu g kg(-1) for Pb. These values were three times lower than the limits found when these metals were calibrated using linear calibration with aqueous standard solutions. (c) 2006 Elsevier B.V. All rights reserved.
dc.description71
dc.description2
dc.description620
dc.description626
dc.languageen
dc.publisherElsevier Science Bv
dc.publisherAmsterdam
dc.publisherHolanda
dc.relationTalanta
dc.relationTalanta
dc.rightsfechado
dc.rightshttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dc.sourceWeb of Science
dc.subjectTS-FF-AAS
dc.subjectsludge slurry samples
dc.subjectpartial least squares
dc.subjectatomic absorption spectrometry
dc.subjectsample preparation
dc.subjectAtomic-absorption-spectrometry
dc.subjectAcid-extractable Metals
dc.subjectLead
dc.subjectInterferences
dc.subjectCadmium
dc.subjectPreconcentration
dc.subjectRegression
dc.subjectChemistry
dc.subjectPb
dc.titleTS-FF-AAS and multivariate calibration: A proposition for sewage sludge slurry sample analyses
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución