dc.creator | Garcia, CAB | |
dc.creator | Neto, GD | |
dc.creator | Kubota, LT | |
dc.creator | Grandin, LA | |
dc.date | 1996 | |
dc.date | 44501 | |
dc.date | 2014-12-16T11:34:40Z | |
dc.date | 2015-11-26T17:05:10Z | |
dc.date | 2014-12-16T11:34:40Z | |
dc.date | 2015-11-26T17:05:10Z | |
dc.date.accessioned | 2018-03-28T23:53:30Z | |
dc.date.available | 2018-03-28T23:53:30Z | |
dc.identifier | Journal Of Electroanalytical Chemistry. Elsevier Science Sa Lausanne, v. 418, n. 41671, n. 147, n. 151, 1996. | |
dc.identifier | 0022-0728 | |
dc.identifier | WOS:A1996WA97600019 | |
dc.identifier | 10.1016/S0022-0728(96)04775-4 | |
dc.identifier | http://www.repositorio.unicamp.br/jspui/handle/REPOSIP/76137 | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/76137 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/76137 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1279514 | |
dc.description | A carbon paste modified with silica gel coated with Meldola's Blue and fructose 5-dehydrogenase was used to construct a new biosensor for fructose. An efficient electron transfer mediation from the reduced enzyme to the carbon paste electrode was verified, at a low applied potential of 20mV vs. SCE, where interfering reactions are minimized. A linear response range for 0.1 to 0.8 mmol(-1) fructose was adjusted by the equation I=0.0150(+/-0.006)+0.618(+/-0.011) [fructose], with a correlation coefficient of 0.999 and an rsd of 0.68% for n=7. The biosensor was used to determine fructose in sweets and fruit jellies and the results present good recovery, higher than 96% in both cases. A stable response is observed over two months, when stored in a refrigerator, or for 300 measurements in continuous use. | |
dc.description | 418 | |
dc.description | 41671 | |
dc.description | 147 | |
dc.description | 151 | |
dc.language | en | |
dc.publisher | Elsevier Science Sa Lausanne | |
dc.publisher | Lausanne | |
dc.publisher | Suíça | |
dc.relation | Journal Of Electroanalytical Chemistry | |
dc.relation | J. Electroanal. Chem. | |
dc.rights | fechado | |
dc.rights | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dc.source | Web of Science | |
dc.subject | biosensors | |
dc.subject | fructose | |
dc.subject | Meldola's Blue mediator | |
dc.subject | modified silica gel | |
dc.subject | fructose 5-dehydrogenase | |
dc.subject | Flow-injection Analysis | |
dc.subject | Glucose | |
dc.subject | Enzyme | |
dc.subject | Dehydrogenase | |
dc.subject | Chromatography | |
dc.subject | Mixtures | |
dc.subject | Platinum | |
dc.subject | Mediator | |
dc.subject | Sucrose | |
dc.subject | Surface | |
dc.title | A new amperometric biosensor for fructose using a carbon paste electrode modified with silica gel coated with Meldola's Blue and fructose 5-dehydrogenase | |
dc.type | Artículos de revistas | |