dc.creatorPrado, M
dc.creatorSimao, RA
dc.creatorGomes, BPFA
dc.date2013
dc.dateMAY
dc.date2014-07-30T17:05:32Z
dc.date2015-11-26T16:48:17Z
dc.date2014-07-30T17:05:32Z
dc.date2015-11-26T16:48:17Z
dc.date.accessioned2018-03-28T23:34:42Z
dc.date.available2018-03-28T23:34:42Z
dc.identifierJournal Of Endodontics. Elsevier Science Inc, v. 39, n. 5, n. 689, n. 692, 2013.
dc.identifier0099-2399
dc.identifierWOS:000319031900022
dc.identifier10.1016/j.joen.2012.12.009
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/63864
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/63864
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1275098
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.descriptionIntroduction: The aim of this study was to evaluate the influence of different irrigation protocols on resin-based sealer bond strength to dentin and the associated failure pattern. Methods: One hundred eighty single-rooted premolars were used. Roots were divided into 18 groups according to the irrigation protocol used and instrumented using 5.25% NaOCl or 2% chlorhexidine (CHX) gel as chemical auxiliary substances and 17% EDTA or 37% phosphoric acid for smear layer removal. Finally, CHX solution was used as the final irrigant in some groups. Root canals were filled with either gutta-percha and AH Plus (Dentsply, Petropolis, RJ, Brazil) (GP/AH) or Resilon/Real Seal SE (SybronEndo, Orange, CA). Bond strength was measured by the push-out test. Additionally, failure patterns were classified as adhesive, cohesive, and mixed. Data were statistically analyzed by Kruskal-Wallis and Mann-Whitney U tests. Results: In the GP/AH groups, high bond strength values were obtained when NaOCl was associated with phosphoric acid with (6.9 +/- 3.9) and without (7.4 +/- 3.8) a final flush with CHX. However, when CHX gel was used, the association with EDTA with (7.5 +/- 3.2) and without (6.0 +/- 2.3) a final flush with CHX solution showed better results. The GP/AH groups mainly showed a cohesive failure pattern. Evaluation of Resilon/Real Seal SE showed that higher bond strength values were reached when CHX was associated with phosphoric acid with (5.2 +/- 3.0) and without (4.2 +/- 2.0) a final flush with CHX solution. The failure patterns were mainly adhesive. Conclusions: Irrigation protocols influenced the bond strength of resin sealers to dentin.
dc.description39
dc.description5
dc.description689
dc.description692
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.descriptionFAPESP [2009/53976-0, 2010/50817-5]
dc.descriptionCNPq [302575/2009-0]
dc.languageen
dc.publisherElsevier Science Inc
dc.publisherNew York
dc.publisherEUA
dc.relationJournal Of Endodontics
dc.relationJ. Endod.
dc.rightsfechado
dc.rightshttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dc.sourceWeb of Science
dc.subjectBond strength
dc.subjectfinal flush
dc.subjectirrigants
dc.subjectresin-based sealers
dc.subjectResilon/epiphany Self-etch
dc.subjectRoot-canal Irrigants
dc.subjectEndodontic Irrigants
dc.subjectSodium-hypochlorite
dc.subjectSoft-tissue
dc.subjectDissolution
dc.subjectAbility
dc.subjectGel
dc.titleEffect of Different Irrigation Protocols on Resin Sealer Bond Strength to Dentin
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución