dc.creatorFinoti, RG
dc.creatorBraile, DM
dc.creatorCroti, UA
dc.creatorde Oliveira, MAB
dc.creatorde Godoy, MF
dc.creatorLeal, JCF
dc.creatorPolicarpo, SR
dc.creatorLopes, ML
dc.date2008
dc.dateJUL-SEP
dc.date2014-07-30T17:28:02Z
dc.date2015-11-26T16:44:12Z
dc.date2014-07-30T17:28:02Z
dc.date2015-11-26T16:44:12Z
dc.date.accessioned2018-03-28T23:29:29Z
dc.date.available2018-03-28T23:29:29Z
dc.identifierRevista Brasileira De Cirurgia Cardiovascular. Soc Brasil Cirurgia Cardiovasc, v. 23, n. 3, n. 358, n. 364, 2008.
dc.identifier0102-7638
dc.identifierWOS:000265694700012
dc.identifier10.1590/S0102-76382008000300012
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/65836
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/65836
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1273847
dc.descriptionObjective: To analyze the security and efficacy of a new membrane oxygenator, the so-called OXM - 1500. Methods: From May 2005 to September 2006, six sheep of Santa Ines breed (five male and one female, respectively) were studied. The average body weight was 14.1 (+/- 5) kg, body surface 0.6 (+/- 0.2) m(2) and a mean age 3.8 (+/- 1.5) months. All of them were submitted to extracorporeal circulation (CEC) with evaluation at 10, 30,60,120,180 and 240 minutes. The following values were obtained: values of oxygen transference (TTO(2)) and carbon dioxide transference (TTCO(2)), haemoglobin (HBS) and free haemoglobin (HBL), the score of platelets and of leucocytes, and heat transference rate. Results: TTO(2) and TTCO(2) were adequate. Lesion of the majority formed blood elements was insignificant; there no modifications in HBS, HBL levels; platelets and leucocytes decreased over time. Heat exchange was effective (p < 0.05). Conclusions: The membrane OXM - 1500 infant oxygenator, tested in sheep, showed adequate oxygenation capacity, CO(2) removal capacity, and small alteration of haemoglobin and platelets without significant decrease of leucocytes, as expected. Heat exchanger connected to the oxygenator was efficient in temperature changes.
dc.description23
dc.description3
dc.description358
dc.description364
dc.languagept
dc.publisherSoc Brasil Cirurgia Cardiovasc
dc.publisherSao Paulo Sp
dc.publisherBrasil
dc.relationRevista Brasileira De Cirurgia Cardiovascular
dc.relationRev. Bras. Cir. Cardiovasc.
dc.rightsaberto
dc.sourceWeb of Science
dc.subjectExtracorporeal membrane oxygenation
dc.subjectExtracorporeal circulation
dc.subjectSheep
dc.subjectCardiopulmonary Bypass
dc.subjectInflammatory Response
dc.subjectProstaglandin-e1
dc.titleEvaluation of infant membrane oxygenator in sheep
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución