dc.creator | Trindade, FCL | |
dc.creator | Freitas, W | |
dc.creator | Vieira, JCM | |
dc.date | 2014 | |
dc.date | FEB | |
dc.date | 2014-07-30T17:34:42Z | |
dc.date | 2015-11-26T16:39:12Z | |
dc.date | 2014-07-30T17:34:42Z | |
dc.date | 2015-11-26T16:39:12Z | |
dc.date.accessioned | 2018-03-28T23:22:44Z | |
dc.date.available | 2018-03-28T23:22:44Z | |
dc.identifier | Ieee Transactions On Power Delivery. Ieee-inst Electrical Electronics Engineers Inc, v. 29, n. 1, n. 251, n. 260, 2014. | |
dc.identifier | 0885-8977 | |
dc.identifier | 1937-4208 | |
dc.identifier | WOS:000330768900030 | |
dc.identifier | 10.1109/TPWRD.2013.2272057 | |
dc.identifier | http://www.repositorio.unicamp.br/jspui/handle/REPOSIP/66817 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/66817 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1272415 | |
dc.description | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description | This paper proposes a fault-location method based on smart feeder meters with voltage sag monitoring capability. The main idea is to explore voltage measurements from monitors placed in different buses of distribution systems to estimate the fault location. The estimation is achieved by relating the voltage deviation measured by each meter to the fault current calculated based on the bus impedance matrix, considering the fault in different points. In order to improve the method accuracy, the loads are represented by constant impedance models and included into the bus impedance matrix. The performance of the proposed method is demonstrated by using a real distribution system. Sensitivity studies results show that the method is robust since it has good performance for different values of fault resistance, quantity, and location of the smart meters. | |
dc.description | 29 | |
dc.description | 1 | |
dc.description | 251 | |
dc.description | 260 | |
dc.description | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.language | en | |
dc.publisher | Ieee-inst Electrical Electronics Engineers Inc | |
dc.publisher | Piscataway | |
dc.publisher | EUA | |
dc.relation | Ieee Transactions On Power Delivery | |
dc.relation | IEEE Trans. Power Deliv. | |
dc.rights | fechado | |
dc.rights | http://www.ieee.org/publications_standards/publications/rights/rights_policies.html | |
dc.source | Web of Science | |
dc.subject | Fault location | |
dc.subject | power distribution | |
dc.subject | smart feeder meter | |
dc.subject | voltage measurement | |
dc.subject | Sag Source Detection | |
dc.subject | Power | |
dc.title | Fault Location in Distribution Systems Based on Smart Feeder Meters | |
dc.type | Artículos de revistas | |