dc.creator | Faundes, D | |
dc.creator | Perdigao, A | |
dc.creator | Faundes, A | |
dc.creator | Bahamondes, L | |
dc.creator | Petta, CA | |
dc.date | 2000 | |
dc.date | OCT | |
dc.date | 2014-12-02T16:25:26Z | |
dc.date | 2015-11-26T16:16:25Z | |
dc.date | 2014-12-02T16:25:26Z | |
dc.date | 2015-11-26T16:16:25Z | |
dc.date.accessioned | 2018-03-28T23:01:40Z | |
dc.date.available | 2018-03-28T23:01:40Z | |
dc.identifier | Contraception. Elsevier Science Inc, v. 62, n. 4, n. 165, n. 168, 2000. | |
dc.identifier | 0010-7824 | |
dc.identifier | WOS:000166072500002 | |
dc.identifier | 10.1016/S0010-7824(00)00167-0 | |
dc.identifier | http://www.repositorio.unicamp.br/jspui/handle/REPOSIP/77049 | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/77049 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/77049 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1267513 | |
dc.description | The objective of this study was to observe the position dynamics of the T-shaped intrauterine device (IUD) in the uterine cavity, from insertion to 90 days of use. IUD position was evaluated in 214 women by vaginal ultrasound, measuring the IUD-endometrium, IUD-myometrium, and IUD-fundus distances. The 90th percentile of the IUD-endometrium distance was 5, 6, and 8 mm at time of insertion, 30 and 90 days of use; 7, 9, and 10 mm for IUD-myometrium distance; and 23, 24, and 27 mm for IUD-fundus distance, respectively. Seventeen IUDs were classified as misplaced at insertion by using the 90th percentile of the IUD-myometrium distance as standard. Of these, only 6 remained misplaced after 90 days of use. On the other hand, 21 IUDs were beyond the 90th percentile at the 90-day observation, only 6 of which were considered misplaced at insertion. We conclude that the T-shaped IUD accommodates its position in the uterine cavity during the first 3 months following insertion, and that ultrasound evaluation of its position is not a good predictor of future evoluation. (C) 2000 Elsevier Science Inc. All rights reserved. | |
dc.description | 62 | |
dc.description | 4 | |
dc.description | 165 | |
dc.description | 168 | |
dc.language | en | |
dc.publisher | Elsevier Science Inc | |
dc.publisher | New York | |
dc.publisher | EUA | |
dc.relation | Contraception | |
dc.relation | Contraception | |
dc.rights | fechado | |
dc.rights | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dc.source | Web of Science | |
dc.subject | intrauterine device | |
dc.subject | ultrasound | |
dc.subject | position | |
dc.subject | Ultrasonography | |
dc.title | T-shaped IUDs accommodate in their position during the first 3 months after insertion | |
dc.type | Artículos de revistas | |