Artículos de revistas
Strain-Temperature Discrimination Using Multimode Interference in Tapered Fiber
Registro en:
Ieee Photonics Technology Letters. Ieee-inst Electrical Electronics Engineers Inc, v. 25, n. 2, n. 155, n. 158, 2013.
1041-1135
WOS:000313884100014
10.1109/LPT.2012.2230617
Autor
Andre, RM
Biazoli, CR
Silva, SO
Marques, MB
Cordeiro, CMB
Frazao, O
Institución
Resumen
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) Tapering single-mode-multimode-single-mode structures to enhance sensitivity is proposed and experimentally demonstrated. 50-mm-long coreless multimode fiber sections are spliced between single-mode fibers (SMFs) and tapered. They are characterized in strain, and an increase in strain sensitivity is obtained with taper diameter reduction. Sensitivities as high as -23.69 pm/mu epsilon for the 15-mu m taper are attained. Temperature sensitivities also depend on taper diameter. A combination of two different diameter tapered SMF MMF-SMF structures, with cross-sensitivity to strain and temperature, is proposed as a sensing system for the simultaneous measurement of strain and temperature with resolutions of +/-5.6 mu epsilon and +/-1.6 degrees C, respectively. A good condition number of 3.16 is achieved with this sensing structure. 25 2 155 158 FINEP Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) Fundacao Calouste Gulbenkian Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)