dc.creatorBorghi-Silva, A
dc.creatorReis, MS
dc.creatorMendes, RG
dc.creatorPantoni, CBF
dc.creatorSimoes, RP
dc.creatorMartins, LEB
dc.creatorCatai, AM
dc.date2008
dc.dateAUG
dc.date2014-11-14T15:12:33Z
dc.date2015-11-26T16:07:14Z
dc.date2014-11-14T15:12:33Z
dc.date2015-11-26T16:07:14Z
dc.date.accessioned2018-03-28T22:55:56Z
dc.date.available2018-03-28T22:55:56Z
dc.identifierRespiratory Medicine. W B Saunders Co Ltd, v. 102, n. 8, n. 1117, n. 1123, 2008.
dc.identifier0954-6111
dc.identifierWOS:000258488900005
dc.identifier10.1016/j.rmed.2008.03.016
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/61999
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/61999
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/61999
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1266083
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionObjective: The purpose of present study was to evaluate the acute effects of bi-level positive airway pressure (BiPAP) on heart rate variability (HRV) of stable chronic obstructive pulmonary disease patients (COPD). Methods: Nineteen mates with COPD (69 +/- 8 years and with forced expiratory volume in 1 s <50% of predicted) and eight healthy sedentary age-matched (69 years) males in the control group (CG) were evaluated during two conditions of controlled respiratory rate: spontaneous breathing (SB) and BiPAP (inspiratory and expiratory levels between 12-14 cmH(2)O and 4-6 cmH(2)O, respectively). Peripheral oxygen saturation (SpO(2)), end-tidal of carbon dioxide (ETCO2), systolic blood pressure (SBP) and R-R interval were obtained. HRV was analyzed by time (RMSSD and SDNN index) and frequency domains (high frequency - HF, low frequency - LF and HF/LF ratio). Results: Significant reduction of ETCO2 and SBP in both groups and increase of SpO(2) in COPD group was observed during BiPAP ventilation (p < 0.05). During spontaneous breathing, patients with COPD presented lower values of LF, LF/HF and higher values of HF when compared to CG (p < 0.05). However, HF was significantly reduced and LF increased during BiPAP ventilation (58 +/- 19-48 +/- 15 and 41 +/- 19-52 +/- 15un, respectively) in COPD group. Significant correlations between delta BiPAP-SB (Delta) ETCO2 and Delta HF were found (r = 0.89).
dc.description102
dc.description8
dc.description1117
dc.description1123
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionFAPESP [05/59427-7]
dc.languageen
dc.publisherW B Saunders Co Ltd
dc.publisherLondon
dc.publisherInglaterra
dc.relationRespiratory Medicine
dc.relationRespir. Med.
dc.rightsfechado
dc.sourceWeb of Science
dc.subjectchronic obstructive pulmonary disease
dc.subjectbi-level positive airway pressure
dc.subjectheart rate variability
dc.subjectPositive Airway Pressure
dc.subjectAcute Respiratory-failure
dc.subjectSpontaneous Baroreflex
dc.subjectSleep-apnea
dc.subjectCopd
dc.subjectDysfunction
dc.subjectStandards
dc.subjectInterval
dc.subjectSupport
dc.subjectSystem
dc.titleNoninvasive ventilation acutely modifies heart rate variability in chronic obstructive pulmonary disease patients
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución