Artículos de revistas
Peak Pressure And Tidal Volume Are Affected By How The Neonatal Self-inflating Bag Is Handled
Registro en:
Jornal De Pediatria. , v. 85, n. 3, p. 217 - 222, 2009.
217557
10.2223/JPED.1886
2-s2.0-67049142829
Autor
Bassani M.A.
Mezzacappa Filho F.
Coppo M.R.C.
Marba S.T.M.
Institución
Resumen
Objective: To evaluate how different ways of handling the neonatal self-inflating bag influence peak pressure and tidal volume. Methods: This is an experimental study involving 141 different professionals (physicians, resident physicians, physiotherapists, nurses, and nursing technicians), who ventilated an artificial lung, adjusted to simulate the lung of a term neonate, using a self-inflating bag. Each professional handled the ventilator in five different ways: a) using both hands (10 fingers); and, with only one hand, b) five fingers, c) four fingers, d) three fingers, and e) two fingers. Peak pressure and tidal volume data were recorded by the artificial lung equipment. Results: Both variables showed high variability, from 2.5 to 106.3 cmH2O (mean = 39.73 cmH2O; 95%CI 37.32-42.13) for peak pressure, and from to 4 to 88 mL (mean = 39.56 mL; 95%CI 36.86-42.25) for tidal volume. There was no significant influence of the profession on any of the variables (p > 0.05). However, bag handling significantly influenced both peak pressure and tidal volume (p < 0.0001), which were higher when the operator used both hands. Conclusion: The results indicate that most professionals delivered excessively high peak pressures and tidal volumes, which could increase the risk of barotrauma and volutrauma, especially when both hands were used to ventilate. On the other hand, a small number of professionals delivered insufficient pressure and volume for adequate lung expansion and ventilation. The delivery of inadequate ventilation was not dependent on profession. Copyright © 2009 by Sociedade Brasileira de Pediatria. 85 3 217 222 Spears Jr., R.S., Yeh, A., Fisher, D.M., Zwass, M.S., "The educated hand". Can anesthesiologists assess changes in neonatal pulmonary compliance manually? (1991) Anesthesiology, 75, pp. 693-696 The International Liaison Committee on Resuscitation (ILCOR) consensus on science with treatment recommendations for pediatric and neonatal patients: Pediatric basic and advanced life support (2006) Pediatrics, 117, pp. e955-77. , International Liaison Committee on Resuscitation Denehy, L., The use of manual hyperinflation in airway clearance (1999) European Respiratory Journal, 14 (4), pp. 958-965. , DOI 10.1034/j.1399-3003.1999.14d38.x 2005 American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC) of pediatric and neonatal patients: Pediatric basic life support (2006) Pediatrics, 117, pp. e989-1004 Almeida, M.F., Guinsburg, R., Controvérsias em reanimação do recémnascido (2001) J Pediatr, 77 (SUPPL. 1), pp. S41-52. , Rio J O'Donnell, C.P.F., Davis, P.G., Morley, C.J., Positive pressure ventilation at neonatal resuscitation: Review of equipment and international survey of practice (2004) Acta Paediatrica, International Journal of Paediatrics, 93 (5), pp. 583-588. , DOI 10.1080/08035250410026581 O'Donnell, C.P., Davis, P.G., Morley, C.J., Resuscitation of premature infants: What are we doing wrong and can we do better? (2003) Biol Neonate, 84, pp. 76-82 Augustine, J.A., Seidel, D.R., McCabe, J.B., Ventilation performance using a self-inflating anesthesia bag: Effect of operator characteristics (1987) Am J Emerg Med, 5, pp. 267-270 Finer, N.N., Rich, W., Craft, A., Henderson, C., Comparison of methods of bag and mask ventilation for neonatal resuscitation (2001) Resuscitation, 49 (3), pp. 299-305. , DOI 10.1016/S0300-9572(01)00311-2, PII S0300957201003112 Hodgson, C., Carroll, S., Denehy, L., A survey of manual hyperinflation in Australian hospitals (1999) Australian Journal of Physiotherapy, 45 (3), pp. 185-193 Maxwell, L., Ellis, E.R., The effects of three manual hyperinflation techniques on pattern of ventilation in a test lung model (2002) Anaesthesia and Intensive Care, 30 (3), pp. 283-288 McCarren, B., Chow, C.M., Manual hyperinflation: A description of the technique (1996) Australian Journal of Physiotherapy, 42 (3), pp. 203-208 Hussey, S.G., Ryan, C.A., Murphy, B.P., Comparison of three manual ventilation devices using an intubated mannequin (2004) Archives of Disease in Childhood: Fetal and Neonatal Edition, 89 (6), pp. F490-F493. , DOI 10.1136/adc.2003.047712 Law, G.D., Effect of hand size on Ve, Vt, and FiO2 during manual resuscitation (1982) Respir Care, 27, pp. 1236-1238 Hess, D., Goff, G., Johnson, K., The effect of hand size, resuscitator brand, and use of two hands on volumes delivered during adult bag-valve ventilation (1989) Respiratory Care, 34 (9), pp. 805-810 Hess, D., Spahr, C., An evaluation of volumes delivered by selected adult disposable resuscitators: The effects of hand size, number of hands used, and use of disposable medical gloves (1990) Respir Care, 35, pp. 800-805 Hess, D., Goff, G., The effect of two-hand versus one-hand ventilation on volumes delivered during bag-valve ventilation at various resistances and compliances (1987) Respir Care, 32, pp. 1025-1028 Hess, D., Simmons, M., Blaukovitch, S., Lightner, D., Doyle, T., An evaluation of the effects of fatigue, impedance, and use of two hands on volumes delivered during bag-valve ventilation (1993) Respiratory Care, 38 (3), pp. 271-275 Dreyfuss, D., Saumon, G., Ventilator-induced lung injury: Lessons from experimental studies (1998) American Journal of Respiratory and Critical Care Medicine, 157 (1), pp. 294-323 Almeida, M.F., Guinsburg, R., A reanimação do prematuro extremo em sala de parto (2005) J Pediatr, 81, pp. S3-15. , Rio J Miyoshi, M., Guinsburg, R., Ventilação pulmonar mecânica convencional no período neonatal (2004) Diagnóstico e Tratamento Em Neonatologia, pp. 149-159. , Kopelman BI, Santos AMN, Goulart AL, Almeida MF, Miyoshi MH, Guinsburg R, editores. São Paulo, SP: Atheneu Ganga-Zandzou, P.S., Diependaele, J.F., Storme, L., Riou, Y., Klosowski, S., Rakza, T., La ventilation à Ambú® chez nouveau-né: Une simple question de doigté? (1996) Arch Pediatr, 3, pp. 1270-1272 Paradine, C.G., Rivett, B.H., (1974) Métodos Estatísticos para Tecnologias, , São Paulo, SP: Polígono da Editora da Universidade de São Paulo; (2005) 2005 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Part 7: Neonatal Resuscitation, 67, pp. 293-303. , International Liaison Committee on Resuscitation De Resende, J.G., Menezes, C.G., Paula, A.M.C., Ferreira, A.C.P., Zaconeta, C.A.M., Silva, C.A.M., Rodrigues, M.P., Tavares, P., Evaluation of peak inspiratory pressure and respiratory rate during ventilation of an infant lung model with a self-inflating bag (2006) Jornal de Pediatria, 82 (5), pp. 359-364. , http://www.jped.com.br/conteudo/06-82-05-359/port.pdf, DOI 10.2223/JPED.1524 Resende, J.G., Zaconeta, C.A.M., Ferreira, A.C.P., Silva, C.A.M., Rodrigues, M.P., Rebello, C.M., Tavares, P., Evaluation of peak inspiratory pressure, tidal volume and respiratory rate during ventilation of premature lambs using a self-inflating bag (2006) Jornal de Pediatria, 82 (4), pp. 279-283. , http://www.jped.com.br/conteudo/06-82-04-279/port.pdf, DOI 10.2223/JPED.1517 Finer, N.N., Barrington, K.J., Al-Fadley, F., Peters, K.L., Limitations of self-inflating resuscitators (1986) Pediatrics, 77 (3), pp. 417-420 Goldstein, B., Catlin, E.A., Vetere, J.M., Arguin, L.J., The role of in-line manometers in minimizing peak and mean airway pressure during the hand-regulated ventilation of newborn infants (1989) Respiratory Care, 34 (1), pp. 23-27 Redfern, J., Ellis, E., Holmes, W., The use of a pressure manometer enhances student physiotherapists' performance during manual hyperinflation (2001) Australian Journal of Physiotherapy, 47 (2), pp. 121-131 Godoy, A.C., Vieira, R.J., De Capitani, E.M., Alterações de pico inspiratório e do volume corrente fornecidos por reanimadores manuais com balão auto-inflável em função do fluxo de entrada de oxigênio utilizado (2008) J Bras Pneumol, 34, pp. 817-821