Artículos de revistas
The Clock Drawing Test: A Review Of Its Accuracy In Screening For Dementia [o Teste Do Desenho Do Relógio: Revisão Da Acurácia No Rastreamento De Demência]
Registro en:
Dementia E Neuropsychologia. , v. 3, n. 2, p. 74 - 80, 2009.
19805764
2-s2.0-79955110868
Autor
Aprahamian I.
Martinelli J.E.
Neri A.L.
Yassuda M.S.
Institución
Resumen
The Clock Drawing Test (CDT) is a simple neuropsychometric instrument that can be easily applied to assess several cognitive functions. Over the past 20 years, the CDT has aroused considerable interest in its role for the early screening of cognitive impairment, especially in dementia. Although the CDT is considered an accurate test for dementia screening, recent studies including comparisons with structured batteries such as the CAMCOG have shown mixed results. Objectives: To investigate the importance of the CDT compared to other commonly used tests, in the diagnosis of dementia in the elderly; (2) to evaluate the reliability and correlation between available CDT scoring scales from recent studies. Methods: A systematic search in the literature was conducted in September 2008 for studies comparing CDT scoring systems and comparing the CDT with neuropsychiatric batteries. Results: Twelve studies were selected for analyses. Seven of these studies compared CDT scoring scales while five compared the CDT against the CAMCOG and the MMSE. Eight studies found good correlation and reliability between the scales and the other tests. Conclusion: Despite the mixed results in these studies, the CDT appears to be a good screening test for dementia. 3 2 74 80 Shulman, K.I., Clock-drawing: Is it the ideal cognitive screening test? (2000) Int J Geriatr Psychiatry, 15, pp. 548-561 Critchley, M., (1953) The Parietal Lobes, , New York, NY: Hafner Publishing Company Freedman, M., Leach, L., Kaplan, E., Clock-drawing: A neuropsychological analysis (1994), New York NY: Oxford University PressGoodglass, H., Kaplan, E., (1983) The Assessment of Aphasia and Related Disorders, , Philadelphia, PA: Lea and Febiger Moore, V., Wyke, M.A., Drawing disability in patients with senile dementia (1984) Psychol Med, 14, pp. 97-105 Villa, G., Gainotti, G., de Bonis, C., Constructional disabilities in focal brain damaged patients: Influence of hemispheric side, locus of lesion and coexistent mental deterioration (1986) Neuropsychologia, 24, pp. 497-510 Henderson, V.W., Mack, W., Williams, B.W., Spatial orientation in Alzheimer's disease (1989) Arch Neurol, 46, pp. 391-394 Libon, D.J., Swenson, R., Barnoski, E., Sands, L.T., Clock drawing as an assessment tool in dementia (1993) Arch Clin Neuropsychol, 8, pp. 405-416 Rouleau, I., Salmon, D.P., Butters, N., Quantitative and qualitative analyses of clock drawings in Alzheimer's and Huntington's Disease (1992) Brain Cogn, 18, pp. 70-87 Sunderland, T., Hill, J.L., Mellow, A.M., Clock drawing in Alzheimer's disease: A novel measure of dementia severity (1989) J Am Geriatr Soc, 37, pp. 725-729 Tuokko, H., Hadjistavropoulos, T., Miller, J.A., Beattie, B.L., The clock test: A sensitive measure to differentiate normal elderly from those with Alzheimer disease (1992) J Am Geriatr Soc, 40, pp. 579-584 Wolf-Klein, G.P., Silverstone, F.A., Levy, A.P., Brod, M., Screening of Alzheimer's disease by clock drawing (1989) J Am Geriatr Soc, 37, pp. 730-734 Shulman, K.I., Shedletsky, R., Silver, I.L., The challenge of time: Clock-drawing and cognitive function in the elderly (1986) Int J Geriatr Psychiatry, 1, pp. 135-140 Borson, S., Brush, M., Gil, E., The clock drawing test: Utility for dementia detection in multiethnic elders (1999) J Gerontol a Biol Sci Med Sci, 54, pp. 534-540 Fuzikawa, C., Lima-Costa, M.F., Uchoa, E., Barreto, S.M., Shul-Man, K.I., A population-based study on the intra- and inter- rater reliability of the Clock-Drawing Test in Brazil: The Bambui Health and Ageing Study (2003) Int J Geriatr Psychiatry, 18, pp. 450-456 Heinik, J., Solomesh, I., Berkman, P., Correlation between the CAMCOG, the MMSE, and three clock drawing tests in a specialized outpatient psychogeriatric service (2004) Arch Gerontol Geriatr, 38, pp. 77-84 Juby, A., Tench, S., Baker, V., The value of clock drawing in identifying executive cognitive dysfunction in people with a normal Mini-mental State Examination score (2002) CMAJ, (167), pp. 859-864 Royall, D.R., Mulroy, A.R., Chiodo, L.K., Polk, M.J., Clock drawing is sensitive to executive control: A comparison of six methods (1999) J Gerontol Psychol Sci Soc Sci, 54, pp. P328-P333 Scanlan, J.M., Brush, M., Quijano, C., Borson, S., Comparing clock tests for dementia screening: Naive judgments vs formal systems-what is optimal? (2002) Int J Geriatr Psychiatry, 17, pp. 14-21 Shulman, K.I., Herrmann, N., Brodaty, H., IPA survey of brief cognitive screening instruments (2006) Int Psychogeriatr, 18, pp. 281-294 Bourke, J., Castleden, C.M., Stephen, R., Dennis, M., A comparison of clock and pentagon drawing in Alzheimer's disease (1995) Int J Geriatr Psychiatry, 10, pp. 703-705 Shulman, K.I., Gold, D.P., Cohen, C.A., Zucchero, C.A., Clock-drawing and dementia in the community: A longitudinal study (1993) Int J Geriatr Psychiatry, 8, pp. 487-496 Watson, Y.I., Arfken, C.L., Birge, S.J., Clock completion: An objective screening test for dementia (1993) J Am Geriatr Soc, 41, pp. 1235-1240 Mendez, M.F., Ala, T., Underwood, K., Development of scoring citeria for the clock drawing task in Alzheimer's disease (1992) J Am Geriatr Soc, 40, pp. 1095-1099 Herrmann, N., Kidron, D., Shulman, K.I., Clock tests in depression, Alzheimer's disease, and elderly controls (1998) Int J Psyquiatry Med, 28, pp. 437-447 Tuokko, H., Hadjistavropoulos, T., Rae, S., O'Rourke, N., A comparison of alternative approaches to the scoring of clock drawing (2000) Arch Clin Neuropsychol, 15, pp. 137-148 Storey, J.E., Rowland, J.T.J., Basic, D., Conforti, D.A., A comparison of five clock scoring methods using ROC (receiver op- erating characteristic) curve analysis (2001) Int J Geriatr Psychiatry, 16, pp. 394-399 Schramm, U., Berger, G., Muller, R., Kratzsch, T., Peters, J., Frol-Ich, L., Psychometric properties of Clock Drawing Test and MMSE or Short Performance Test (SKT) in dementia screening in a memory clinic population (2002) Int J Geriatr Psychiatry, 17, pp. 254-260 Kirby, M., Denihan, A., Bruce, I., Coakley, D., Lawlor, B.A., The clock drawing test in primary care: Sensitivity in dementia de- tection and specificity against normal and depressed elderly (2001) Int J Geriatr Psychiatry, 16, pp. 935-940 Brodaty, H., Moore, C.M., The clock drawing test for dementia of the Alzheimer's type: A comparison of three scoring methods in a memory disorders clinic (1997) Int J Geriatr Psychiatry, 12, pp. 619-627 Richardson, H.E., Glass, J.N., A comparison of scoring protocols on the clock drawing test in relation to ease of use, diagnostic group, and correlations with Mini-Mental State Examination (2002) J Am Geriatr Soc, 50, pp. 169-173 (1994) Diagnostic and Statistical Manual of Mental Disorders, , American Psychiatry Association, 4th ed. Washington, D.C.: Ameri-can Psychiatry Association Manos, P.J., Ten-point clock test sensitivity for Alzheimer's disease in patients with MMSE scores greater than 23 (1999) Int J Geriatr Psychiatry, 14, pp. 454-458 Seigerschmidt, E., Mosch, E., Siemen, M., Förstl, H., Bickel, H., The clock drawing test and questionable dementia: Reliability and validity (2002) Int J Geriatr Psychiatry, 17, pp. 1048-1054 Lam, L.W.C., Chiu, H.F.K., Ng, K.O., Clock-face drawing, reading and setting tests in the screening of dementia in Chinese elderly adults (1998) J Gerontol B Psychol Sci Soc Sci, 53 B, pp. 353-357 Connor, D.J., Seward, J.D., Bauer, J.A., Performance of three clock scoring systems across different ranges of dementia severity (2005) Alzheimer Dis Assoc Disord, 19, pp. 119-127 Lee, H., Swanwick, G.R.J., Cohen, R.F., Lawlor, B.A., Use of the clock drawing test in the diagnosis of mild and very mild Alzheimer's disease (1996) Int Psychogeriatr, 8, pp. 469-476 Powlishta, K.K., von Dras, D.D., Stanford, A., The clock drawing test is a poor screen for very mild dementia (2002) Neurology, 59, pp. 898-903 Lessig, M., Scanlan, J.M., Nazemi, H., Borson, S., Time that tells: Critical clock-drawing errors for dementia screening (2008) Int Psychogeriatr, 20, pp. 459-470 Tombaugh, T.N., McIntyre, N.T., The Mini-Mental State Examination: A comprehensive review (1992) J Am Geriatr Soc, 40, pp. 922-935 Royall, D.R., Cordes, J.A., Polk, M., CLOX: An executive clock drawing task (1998) J Neurol Neurosurg Psychiatry, 64, pp. 588-594 Ferrucci, L., Cecchi, F., Guralnik, J.M., For the FINE Study Group. Does the clock drawing predict cognitive decline in older persons independent of the Mini-Mental State Examination (1996) J Am Geriatr Soc, 44, pp. 1326-1331 Juby, A., Correlation between the Folstein Mini-Mental State Examination and Three Methods of Clock Drawing Scoring (1999) J Geriatr Psychiatry Neurol, 12, pp. 87-91 Nishiwaki, Y., Breeze, E., Smeeth, L., Bulpitt, C.J., Peters, R., Fletcher, A.E., Validity of the Clock-Drawing Test as a screening tool for cognitive impairment in the elderly (2004) Am J Epidemiology, 160, pp. 797-807 Solomon, P.R., Hirschoff, A., Kelly, B., A 7 minute neurocognitive screening battery highly sensitive to Alzheimer's disease (1998) Arch Neurol, 55, pp. 349-355 Scanlan, J., Borson, S., The Mini-Cog: Receiver operating characteristics with expert and naive raters (2001) Int J Geriatr Psychiatry, 16, pp. 216-222 Heinik, J., Solomesh, I., Shein, V., Becker, D., Clock drawing test in mild and moderate dementia of the Alzheimer's type: A comparative and correlation study (2002) Int J Geriatr Psychiatry, 17, pp. 480-485 Heinik, J., Solomesh, I., Bleich, A., Berkman, P., Are the Clock-Drawing Test and the MMSE Combined Interchangeable with CAMCOG as a Dementia Evaluation Instrument in a Specialized Outpatient Setting? (2003) J Geriatr Psychiatry Neurol, 16, pp. 74-79 van der Burg, M., Bouwen, A., Stessens, J., Scoring clock tests for dementia screening: A comparison of two scoring methods (2004) Int J Geriatr Psychiatry, 19, pp. 685-689