dc.creatorTavares M.C.
dc.creatorPissolato J.
dc.creatorPortela C.M.
dc.date1999
dc.date2015-06-30T15:19:49Z
dc.date2015-11-26T15:24:41Z
dc.date2015-06-30T15:19:49Z
dc.date2015-11-26T15:24:41Z
dc.date.accessioned2018-03-28T22:33:33Z
dc.date.available2018-03-28T22:33:33Z
dc.identifier
dc.identifierInternational Journal Of Electrical Power And Energy Systems. , v. 21, n. 8, p. 585 - 601, 1999.
dc.identifier1420615
dc.identifier
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-0003327688&partnerID=40&md5=97f8f3f0b81ab68b6ae1ccffad02d5bc
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/100946
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/100946
dc.identifier2-s2.0-0003327688
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1260747
dc.descriptionThis article presents a new model to represent transmission lines including the frequency dependence of longitudinal parameters. The model uses exact modes, for ideally transposed lines, and "quasi-modes" for non-transposed lines. The line is represented through a cascade of π-circuits, with one π-circuit for each mode. The transformation matrix used is real and it is modeled with ideal transformers. The model is described for three-phase lines, dc lines, double three-phase lines and six-phase lines. An ATP-EMTP implementation of a 440 kV three-phase transmission line is performed to illustrate the model and a comparison with two frequency dependent ATP line models are made, the Semlyen and JMarti ones. © 1999 Elsevier Science Ltd. All rights reserved.
dc.description21
dc.description8
dc.description585
dc.description601
dc.description(1987) Alternative Transients Program Rule Book, , July
dc.descriptionSemlyen, A., Dabuleanu, A., Fast and accurate switching transient calculations on transmission lines with ground return using recursive convolution (1975) IEEE Trans PAS, 94 (2), pp. 561-571
dc.descriptionMarti, J.R., Accurate modeling of frequency-dependent transmission lines in electromagnetic transients simulations (1982) IEEE Trans PAS, 101 (1), pp. 147-157
dc.descriptionClarke, E., (1950) Circuit Analysis of AC Power Systems, 1. , New York: Wiley
dc.descriptionBrandã, O., Faria, J.A., Bricefio Mendez, J., On the modal analysis of asymmetrical three phase transmission lines using standard transformation matrices (1997) IEEE Winter Meeting, , Paper 97WMIEEE-PES
dc.descriptionTavares, M.C., Pissolato, J., Portela, C.M., New mode-domain representation of transmission line-Clarke transformation analysis (1998) 1998 IEEE International Symposium on Circuits and Systems (ISCAS' 98), pp. III497-500. , Monterey, California, USA
dc.descriptionTavares, M.C., Pissolato, J., Portela, C.M., Quasi-modes multiphase transmission line model (1999) Electric Power Systems Research, 49, pp. 159-167
dc.descriptionPortela, C.M., Tavares, M.C., Six phase transmission line-propogation characteristics and new three phase representation (1993) IEEE Trans Power Delivery, 8 (3), pp. 1470-1483
dc.descriptionTavares, M.C., Pissolato, J., Portela, C.M., Mode domain multiphase transmission line-use in transient studies (1998) IEEE Summer Meeting, , Paper PE-430-PWRD-0-04-1988, San Diego, USA, July
dc.descriptionBrandão Faria, J.A., Briceño Mendez, J., Modal analysis of untransposed bilateral three phase lines-a perturbation approach (1996) IEEE Summer Meeting, , Paper 96SM438-2PWRD, Denver, USA, July
dc.descriptionPortela, C.M., Tavares, M.C., Azeved, R.M., New Line Representation for Transient Studies - Application to a Six Phase Transmission Line
dc.descriptionSemlyen, A., Wilson, R.L., Gelopulos, D., Paper discussion of component transformations - Eigenvalue analysis succintly defines their relationships (1982) IEEE Trans PAS, 101, pp. 405-406
dc.languageen
dc.publisher
dc.relationInternational Journal of Electrical Power and Energy Systems
dc.rightsfechado
dc.sourceScopus
dc.titleNew Multiphase Mode Domain Transmission Line Model
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución