A simple method for the determination of mercury in gasoline samples diluted with ethanol by graphite furnace atomic absorption spectrometry (GF AAS) after cold vapor (CV) generation, pre-concentration in a gold column and trapping on a graphite tube is proposed. The methodology is based upon conventional analytical processes that can be performed by any laboratory with a chemical generation and gold amalgamation systems coupled to the atomic absorption spectrometer. The GF AAS temperature was optimized, being the retention, pyrolysis and atomization temperatures, respectively, 100°C, 150°C and 800°C. Gasoline samples were prepared simply by forming a 2-fold diluted solution in ethanol. The mercury formed vapors by reacting the sample with the reducing agent were pre-concentrated in a gold column and further retained on a graphite tube, coated with gold as permanent modifier. Five samples from different gas stations around the UFSC Campus (Florianópolis, Brazil) were analyzed and the Hg concentrations were found to be in the range from 0.40μgL-1 to 0.90μgL-1. Calibration against aqueous standard solutions in acidic medium was carried out. The standard solutions had about the same viscosity as the gasoline diluted in ethanol. The relative standard deviations were lower than 2.4% for the samples. The limits of detection in the samples were 0.08 and 0.14μgL-1, with and without pre-concentration in the gold column, respectively. The accuracy of the method was estimated by applying the recovery test and recovery values between 92 and 100% were obtained. A sample throughput of 4h-1 was achieved. Simplicity and high detection capability are some of the qualities of the method. © 2010 Elsevier B.V. 96 1 32 36 Saint'Pierre, T.D., Dias, L.F., Maia, S.M., Curtius, A.J., Determination of Cd, Cu, Fe, Pb and Tl in gasoline as emulsion by electrothermal vaporization inductively coupled plasma mass spectrometry with analyte addition and isotope dilution calibration techniques (2004) Spectrochim. Acta. Part B., 59, pp. 551-558 Brandão, G.P., Campos, R.C., Luna, A.S., Determination of mercury in gasoline by cold vapor atomic absorption spectrometry with direct reduction in microemulsion media (2005) Spectrochim. Acta. Part B., 60, pp. 625-631 Wilheim, S.M., Bloom, N., Mercury in petroleum (2000) Fuel Process. Technol., 63, pp. 1-27 Saint'Pierre, T.D., Dias, L.F., Pozebon, D., Aucélio, R.Q., Curtius, A.J., Welz, B., Determination of Cu, Mn, Ni and Sn in gasoline by electrothermal vaporization inductively coupled plasma mass spectrometry, and emulsion sample introduction (2002) Spectrochim. Acta. Part B., 57, pp. 1991-2001 Liang, L., Horvat, M., Fajon, V., Prosenc, N., Li, H., Pang, P., Comparison of improved combustion/trap technique to wet extraction methods for determination of mercury in crude oil and related products by atomic fluorescence (2003) Energy Fuels, 17, pp. 1175-1179 Bloom, N.S., Analysis and stability of mercury speciation in petroleum hydrocarbons (2000) Fresenius' J. Anal. Chem., 366, pp. 438-443 Liang, L., Horvat, M., Danilchik, P., A novel analytical method for the determination of pictogram levels of total mercury in gasoline and other petroleum based products (1996) Sci. Total Environ., 187, pp. 57-64 Kelly, W.R., Long, S.E., Mann, J.L., Determination of mercury in SRM crude oil and refined products by isotope dilution cold vapor ICP-MS using closed-system combustion (2003) Anal. Bioanal. Chem., 376, pp. 753-758 dos Santos, W.N.L., Dias, F., Reboucas, M.V., Pereira, M., Pereira, M., Teixeira, L.S.G., Mercury determination in petroleum products by electrothermal atomic absorption spectrometry after in situ preconcentration using multiple injections (2006) J. Anal. At. Spectrom., 21, pp. 1327-1330 Cassela, R.J., Barbosa, B.A.R.S., Santelli, R.E., Rangel, A.T., Direct determination of arsenic and antimony in naphta by electrothermal atomic absorption spectrometry with microemulsion sample introduction and iridium permanent modifier (2004) Anal. Bioanal. Chem., 379, pp. 66-71 Chang, Y.T., Jiang, S.J., Determination of As, Cd and Hg in emulsified vegetable oil by flow injection chemical vapour generation inductively coupled plasma mass spectrometry (2008) J. Anal. At. Spectrom., 23, pp. 140-144 Rivaro, P., Ianni, C., Soggia, F., Frache, R., Mercury speciation in environmental samples by cold vapour atomic absorption spectrometry with in situ preconcentration on a gold trap (2007) Microchim. Acta., 158, pp. 345-352 Welz, B., Sperling, M., (1999) Atomic Absorption Spectrometry, , WILEY-VCH, Weinheim, Germany Conaway, C.H., Mason, R.P., Steding, D.J., Flegal, A.R., Estimate of mercury emission from gasoline and diesel fuel consumption, San Francisco Bay area, California (2005) Atmos. Environ., 39, pp. 101-105 Won, J.H., Park, J.Y., Lee, T.G., Mercury emissions from automobiles using gasoline, diesel and LPT (2007) Atmos. Environ., 41, pp. 7547-7552 Flores, E.M.M., Welz, B., Curtius, A.J., Determination of mercury in mineral coal using cold vapor generation directly from slurries, trapping in a graphite tube, and electrothermal atomization (2001) Spectrochim. Acta. Part B., 56, pp. 1605-1614