dc.creatorLeite F.R.F.
dc.creatorMaroneze C.M.
dc.creatorDe Oliveira A.B.
dc.creatorSantos W.T.P.D.
dc.creatorDamos F.S.
dc.creatorLuz R.D.C.S.
dc.date2012
dc.date2015-06-25T20:23:45Z
dc.date2015-11-26T15:18:52Z
dc.date2015-06-25T20:23:45Z
dc.date2015-11-26T15:18:52Z
dc.date.accessioned2018-03-28T22:28:29Z
dc.date.available2018-03-28T22:28:29Z
dc.identifier
dc.identifierBioelectrochemistry. , v. 86, n. , p. 22 - 29, 2012.
dc.identifier15675394
dc.identifier10.1016/j.bioelechem.2012.01.001
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-84860284285&partnerID=40&md5=7a8559be40ec5bf33ae1212cffe04bb3
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/90077
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/90077
dc.identifier2-s2.0-84860284285
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1259637
dc.descriptionL-Dopa is the immediate precursor of the neurotransmitter dopamine, being the most widely prescribed drug in the treatment of Parkinson's disease. A sensitive and selective method is presented for the voltammetric determination of L-Dopa in pharmaceutical formulations using a basal plane pyrolytic graphite (BPPG) electrode modified with chloro(pyridine)bis(dimethylglyoximato)cobalt(III) (Co(DMG) 2ClPy) absorbed in a multi-walled carbon nanotube (MWCNT). Scanning Electron Microscopy and Fourier Transform Infrared Spectroscopy were used to characterize the materials. The electrocatalytical oxidation of L-Dopa using the Co(DMG) 2ClPy/MWCNT/BPPG electrode was investigated by cyclic voltammetry and square wave voltammetry. The parameters that influence the electrode response (the amount of Co(DMG) 2ClPy and of MWCNT, buffer solution, buffer concentration, buffer pH, frequency and potential pulse amplitude) were investigated. Voltammetric peak currents showed a linear response for L-Dopa concentration in the range of 3 to 100μM, with a sensitivity of 4.43μAcm -2/μM and a detection limit of 0.86μM. The related standard deviation for 10 determinations of 50μML-Dopa was 1.6%. The results obtained for L-Dopa determination in pharmaceutical formulations (tablets) were in agreement with the compared official method. The sensor was successfully applied for L-Dopa selective determination in pharmaceutical formulations. © 2012 Elsevier B.V.
dc.description86
dc.description
dc.description22
dc.description29
dc.descriptionFauci, A.S., Braunwald, E., Kasper, D.L., Hauser, S.L., Longo, D.L., Jameson, J.L., Loscalzo, J., (2008) Harrison's Principles of Internal Medicine, , McGraw-Hill Professional, New York
dc.descriptionTrevor, A.J., Katzung, B.G., Masters, S.B., (2010) Katzung & Trevor's Pharmacology, Examination and Board Review, , McGraw-Hill Medical, New York
dc.descriptionGrünhut, M., Centurión, M.E., Fragoso, W.D., Almeida, L.F., de Araújo, M.C.U., Band, B.S.F., Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm (2008) Talanta, 75, pp. 950-958
dc.descriptionKaur, K., Malik, A.K., Singh, B., Godarzi, M., Simultaneous spectrophotometric determination of carbidopa and levodopa by partial least squares regression, principal component regression and least squares support vector machine methods (2009) Thai J. Pharm. Sci., 33, pp. 123-136
dc.descriptionMarques, K.L., Santos, J.L.M., Lopes, J.A., Lima, J.L.F.C., Simultaneous chemiluminometric determination of levodopa and benzerazide in a multi-pumping flow system with multivariate calibration (2008) Anal. Sci., 24, pp. 985-991
dc.descriptionZhao, S., Bai, W., Wang, B., He, M., Determination of levodopa by capillary electrophoresis with chemiluminescence detection (2007) Talanta, 73, pp. 142-146
dc.descriptionLi, S., Wu, H., Yu, Y., Li, Y., Nie, J., Fu, H., Yu, R., Quantitative analysis of levodopa, carbidopa and methyldopa in human plasma samples using HPLC-DAD combined with second-order calibration based on alternating trilinear decomposition algorithm (2010) Talanta, 81, pp. 805-812
dc.descriptionMuzzi, C., Bertocci, E., Terzuoli, L., Porcelli, B., Ciari, I., Pagani, R., Guerranti, R., Simultaneous determination of serum concentrations of levodopa, dopamine, 3-O-methyldopa and α-methyldopa by HPLC (2008) Biomed. Pharmacother., 62, pp. 253-258
dc.descriptionTalebpour, Z., Haghgoob, S., Shamsipur, M., 1H nuclear magnetic resonance spectroscopy analysis for simultaneous determination of levodopa, carbidopa and methyldopa in human serum and pharmaceutical formulations (2004) Anal. Chim. Acta, 506, pp. 97-104
dc.descriptionAslanoglu, M., Kutluay, A., Goktas, S., Karabulut, S., Voltammetric behaviour of levodopa and its quantification in pharmaceuticals using a β-cyclodextrine doped poly(2,5-diaminobenzenesulfonic acid) modified electrode (2009) J. Chem. Sci., 121, pp. 209-215
dc.descriptionShahrokhian, S., Asadian, E., Electrochemical determination of L-Dopa in the presence of ascorbic acid on the surface of the glassy carbon electrode modified by a bilayer of multi-walled carbon nanotube and poly-pyrrole doped with tiron (2009) J. Electroanal. Chem., 636, pp. 40-46
dc.descriptionEnsafi, A.A., Arabzadeh, A., Karimi-Maleh, H., Sequential determination of benserazide and levodopa by voltammetric method using chloranil as a mediator (2010) J. Braz. Chem. Soc., 21, pp. 1572-1580
dc.descriptionNematollahi, D., Rafiee, M., Fotouhi, L., Mechanistic study of homogeneous reactions coupled with electrochemical oxidation of catechols (2009) J. Iran. Chem. Soc., 6, pp. 448-476
dc.descriptionRafiee, M., Nematollahi, D., Electrochemical oxidation of catechols in the presence of cyanoacetone and methyl cyanoacetate (2009) J. Electroanal. Chem., 626, pp. 36-41
dc.descriptionTeixeira, M.F.S., Bergamini, M.F., Marques, C.M.P., Bocchi, N., Voltammetric determination of L-Dopa using an electrode modified with trinuclear ruthenium ammine complex (Ru-red) supported on Y-type zeolite (2004) Talanta, 63, pp. 1083-1088
dc.descriptionTu, Y., Xu, Q., Zou, Q., Yin, Z., Sun, Y., Zhao, Y., Electrochemical behavior of levodopa at multi-wall carbon nanotubes-quantum dots modified glassy carbon electrodes (2007) Anal. Sci., 23, pp. 1321-1324
dc.descriptionYaghoubian, H., Karimi-Maleh, H., Khalilzadeh, M.A., Karimi, F., Electrocatalytic oxidation of levodopa at a ferrocene modified carbon nanotube paste electrode (2009) Int. J. Electrochem. Sci., 4, pp. 993-1003
dc.descriptionWoollins, J.D., (1994) Inorganic experiments, , VCH, Weinheim
dc.descriptionJaselkis, B., Diehl, H., The polarography of vitamins B12r and B12a (1954) J. Am. Chem. Soc., 76, pp. 4345-4348
dc.descriptionSilvia, R.H., Gustavo, G.R., Héctor, C.G., Enhanced application of square wave voltammetry with glassy carbon electrode coupled to multivariate calibration tools for the determination of B 6 and B 12 vitamins in pharmaceutical preparations (2003) Talanta, 61, pp. 743-753
dc.descriptionLin, M.S., Leu, H.J., Lai, C.H., Development of vitamin B 12 based disposable sensor for dissolved oxygen (2006) Anal. Chim. Acta, 561, pp. 164-170
dc.descriptionDong, S., Chi, L., He, P., Wang, Q., Fang, Y., Simultaneous determination of antioxidants at a chemically modified electrode with vitamin B12 by capillary zone electrophoresis coupled with amperometric detection (2009) Talanta, 80, pp. 809-814
dc.descriptionIijima, S., Helical microtubules of graphitic carbon (1991) Nature, 354, pp. 56-58
dc.descriptionJiang, H., Zhao, Y., Yang, H., Akins, D.L., Synthesis and electrochemical properties of single-walled carbon nanotube-gold nanoparticle composites (2009) Mater. Chem. Phys., 114, pp. 879-883
dc.descriptionShih, Y.F., Chen, L.S., Jeng, R.J., Preparation and properties of biodegradable PBS/multi-walled carbon nanotube nanocomposites (2008) Polymer, 49, pp. 4602-4611
dc.descriptionZhang, Y., Shen, Y., Han, D., Wang, Z., Song, J., Li, F., Niu, L., Carbon nanotubes and glucose oxidase bionanocomposite bridged by ionic liquid-like unit: Preparation and electrochemical properties (2007) Biosens. Bioelectron., 23, pp. 438-443
dc.descriptionRivas, G.A., Rubianes, M.D., Rodríguez, M.C., Ferreyra, N.F., Luque, G.L., Pedano, M.L., Miscoria, S.A., Parrado, C., Carbon nanotubes for electrochemical biosensing (2007) Talanta, 74, pp. 291-307
dc.descriptionHu, C., Hu, S., Carbon nanotube-based electrochemical sensors: Principles and applications in biomedical systems (2009) J. Sens., pp. 1-40. , (Review Article)
dc.descriptionLuz, R.C.S., Damos, F.S., Tanaka, A.A., Kubota, L.T., Gushikem, Y., Electrocatalytic activity of 2,3,5,6-tetrachloro-1,4-benzoquinone/multi-walled carbon nanotubes immobilized on edge plane pyrolytic graphite electrode for NADH oxidation (2008) Electrochim. Acta, 53, pp. 4706-4714
dc.descriptionLuz, R.C.S., Maroneze, C.M., Tanaka, A.A., Kubota, L.T., Gushikem, Y., Damos, F.S., The electrocatalytic activity of a supramolecular assembly of CoTsPc/FeT4MPyP on multi-walled carbon nanotubes towards L-glutathione, and its determination in human erythrocytes (2010) Microchim. Acta, 171, pp. 169-178
dc.descriptionPillay, J., Ozoemena, K.I., Efficient electron transport across nickel powder modified basal plane pyrolytic graphite electrode: Sensitive detection of sulfhydryl degradation products of the V-type nerve agents (2007) Electrochem. Comm., 9, pp. 1816-1823
dc.description(2008), The United States Pharmacopeia - The National Formulary, USP 31 - NF 26, United States Pharmacopeial Convention, RockvilleLee, J., Park, E.J., Choi, J., Hong, J., Shim, S.E., Polyurethane/PEG-modified MWCNT composite film for the chemical vapor sensor application (2010) Synth. Met., 160, pp. 566-574
dc.descriptionDhand, C., Arya, S.K., Singh, S.P., Singh, B.P., Datta, M., Malhotra, B.D., Preparation of polyaniline/multiwalled carbon nanotube composite by novel electrophoretic route (2008) Carbon, 46, pp. 1727-1735
dc.descriptionBorgo, C.A., Lazarin, A.M., Davanzo, C.U., Gushikem, Y., Preparação e caracterização do complexo cobaloxima e sua utilização na construção de um eletrodo modificado. Um experimento eletroquímico no curso de graduação (2003) Quím. Nova, 26, pp. 943-947
dc.descriptionBard, A.J., Faulkner, L.R., (2001) Electrochemical Methods: Fundamentals and Applications, , John Wiley & Sons, New York
dc.descriptionLuz, R.C.S., Damos, F.S., Oliveira, A.B., Beck, J., Kubota, L.T., Development of a voltammetric sensor for catechol in nanomolar levels using a modified electrode with Cu(phen) 2(TCNQ) 2 and PLL (2006) Sens. Actuators B, 117, pp. 274-281
dc.descriptionLaviron, E., Electrochemical reactions with protonations at equilibrium: part II. The 1e, 1 H + reaction (four-member square scheme) for a heterogeneous reaction (1981) J. Electroanal. Chem., 124, pp. 1-7
dc.descriptionPapouchado, L., Sandford, R.W., Petrie, G., Adams, R.N., Anodic oxidation pathways of phenolic compounds: Part 2. Stepwise electron transfers and coupled hydroxylations (1975) J. Electroanal. Chem., 65, pp. 275-284
dc.descriptionRecommendations for the definition, estimation and use of the detection limit (1987) Analyst, 112, pp. 199-204. , Analytical Methods Committee
dc.descriptionTeixeira, M.F.S., Marcolino-Júnior, L.H., Fatibello-Filho, O., Dockal, E.R., Bergamini, M.F., An electrochemical sensor for L-Dopa based on oxovanadium-salen thin film electrode applied flow injection system (2007) Sens. Actuators B, 122, pp. 549-555
dc.descriptionde Melo, H.C., Seleghim, A.P.D., Polito, W.L., Fatibello-Filho, O., Vieira, I.C., Simultaneous differential pulse voltammetric determination of L-Dopa and carbidopa in pharmaceuticals using a carbon paste electrode modified with lead dioxide immobilized in a polyester resin (2007) J. Braz. Chem. Soc., 18, pp. 797-803
dc.descriptionQuintino, M.S.M., Yamashita, M., Angnes, L., Voltammetric studies and determination of levodopa and carbidopa in pharmaceutical products (2006) Electroanalysis, 18, pp. 655-661
dc.descriptionBergamini, M.F., Santos, A.L., Stradiotto, N.R., Zanoni, M.V.B., A disposable electrochemical sensor for the rapid determination of Levodopa (2005) J. Pharm. Biomed. Anal., 39, pp. 54-59
dc.descriptionTriola, M.F., (2008) Introdução à Estatística, , LTC, Rio de Janeiro
dc.languageen
dc.publisher
dc.relationBioelectrochemistry
dc.rightsfechado
dc.sourceScopus
dc.titleDevelopment Of A Sensor For L-dopa Based On Co(dmg) 2clpy/multi-walled Carbon Nanotubes Composite Immobilized On Basal Plane Pyrolytic Graphite Electrode
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución