dc.creator | Leite F.R.F. | |
dc.creator | Maroneze C.M. | |
dc.creator | De Oliveira A.B. | |
dc.creator | Santos W.T.P.D. | |
dc.creator | Damos F.S. | |
dc.creator | Luz R.D.C.S. | |
dc.date | 2012 | |
dc.date | 2015-06-25T20:23:45Z | |
dc.date | 2015-11-26T15:18:52Z | |
dc.date | 2015-06-25T20:23:45Z | |
dc.date | 2015-11-26T15:18:52Z | |
dc.date.accessioned | 2018-03-28T22:28:29Z | |
dc.date.available | 2018-03-28T22:28:29Z | |
dc.identifier | | |
dc.identifier | Bioelectrochemistry. , v. 86, n. , p. 22 - 29, 2012. | |
dc.identifier | 15675394 | |
dc.identifier | 10.1016/j.bioelechem.2012.01.001 | |
dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-84860284285&partnerID=40&md5=7a8559be40ec5bf33ae1212cffe04bb3 | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/90077 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/90077 | |
dc.identifier | 2-s2.0-84860284285 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1259637 | |
dc.description | L-Dopa is the immediate precursor of the neurotransmitter dopamine, being the most widely prescribed drug in the treatment of Parkinson's disease. A sensitive and selective method is presented for the voltammetric determination of L-Dopa in pharmaceutical formulations using a basal plane pyrolytic graphite (BPPG) electrode modified with chloro(pyridine)bis(dimethylglyoximato)cobalt(III) (Co(DMG) 2ClPy) absorbed in a multi-walled carbon nanotube (MWCNT). Scanning Electron Microscopy and Fourier Transform Infrared Spectroscopy were used to characterize the materials. The electrocatalytical oxidation of L-Dopa using the Co(DMG) 2ClPy/MWCNT/BPPG electrode was investigated by cyclic voltammetry and square wave voltammetry. The parameters that influence the electrode response (the amount of Co(DMG) 2ClPy and of MWCNT, buffer solution, buffer concentration, buffer pH, frequency and potential pulse amplitude) were investigated. Voltammetric peak currents showed a linear response for L-Dopa concentration in the range of 3 to 100μM, with a sensitivity of 4.43μAcm -2/μM and a detection limit of 0.86μM. The related standard deviation for 10 determinations of 50μML-Dopa was 1.6%. The results obtained for L-Dopa determination in pharmaceutical formulations (tablets) were in agreement with the compared official method. The sensor was successfully applied for L-Dopa selective determination in pharmaceutical formulations. © 2012 Elsevier B.V. | |
dc.description | 86 | |
dc.description | | |
dc.description | 22 | |
dc.description | 29 | |
dc.description | Fauci, A.S., Braunwald, E., Kasper, D.L., Hauser, S.L., Longo, D.L., Jameson, J.L., Loscalzo, J., (2008) Harrison's Principles of Internal Medicine, , McGraw-Hill Professional, New York | |
dc.description | Trevor, A.J., Katzung, B.G., Masters, S.B., (2010) Katzung & Trevor's Pharmacology, Examination and Board Review, , McGraw-Hill Medical, New York | |
dc.description | Grünhut, M., Centurión, M.E., Fragoso, W.D., Almeida, L.F., de Araújo, M.C.U., Band, B.S.F., Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm (2008) Talanta, 75, pp. 950-958 | |
dc.description | Kaur, K., Malik, A.K., Singh, B., Godarzi, M., Simultaneous spectrophotometric determination of carbidopa and levodopa by partial least squares regression, principal component regression and least squares support vector machine methods (2009) Thai J. Pharm. Sci., 33, pp. 123-136 | |
dc.description | Marques, K.L., Santos, J.L.M., Lopes, J.A., Lima, J.L.F.C., Simultaneous chemiluminometric determination of levodopa and benzerazide in a multi-pumping flow system with multivariate calibration (2008) Anal. Sci., 24, pp. 985-991 | |
dc.description | Zhao, S., Bai, W., Wang, B., He, M., Determination of levodopa by capillary electrophoresis with chemiluminescence detection (2007) Talanta, 73, pp. 142-146 | |
dc.description | Li, S., Wu, H., Yu, Y., Li, Y., Nie, J., Fu, H., Yu, R., Quantitative analysis of levodopa, carbidopa and methyldopa in human plasma samples using HPLC-DAD combined with second-order calibration based on alternating trilinear decomposition algorithm (2010) Talanta, 81, pp. 805-812 | |
dc.description | Muzzi, C., Bertocci, E., Terzuoli, L., Porcelli, B., Ciari, I., Pagani, R., Guerranti, R., Simultaneous determination of serum concentrations of levodopa, dopamine, 3-O-methyldopa and α-methyldopa by HPLC (2008) Biomed. Pharmacother., 62, pp. 253-258 | |
dc.description | Talebpour, Z., Haghgoob, S., Shamsipur, M., 1H nuclear magnetic resonance spectroscopy analysis for simultaneous determination of levodopa, carbidopa and methyldopa in human serum and pharmaceutical formulations (2004) Anal. Chim. Acta, 506, pp. 97-104 | |
dc.description | Aslanoglu, M., Kutluay, A., Goktas, S., Karabulut, S., Voltammetric behaviour of levodopa and its quantification in pharmaceuticals using a β-cyclodextrine doped poly(2,5-diaminobenzenesulfonic acid) modified electrode (2009) J. Chem. Sci., 121, pp. 209-215 | |
dc.description | Shahrokhian, S., Asadian, E., Electrochemical determination of L-Dopa in the presence of ascorbic acid on the surface of the glassy carbon electrode modified by a bilayer of multi-walled carbon nanotube and poly-pyrrole doped with tiron (2009) J. Electroanal. Chem., 636, pp. 40-46 | |
dc.description | Ensafi, A.A., Arabzadeh, A., Karimi-Maleh, H., Sequential determination of benserazide and levodopa by voltammetric method using chloranil as a mediator (2010) J. Braz. Chem. Soc., 21, pp. 1572-1580 | |
dc.description | Nematollahi, D., Rafiee, M., Fotouhi, L., Mechanistic study of homogeneous reactions coupled with electrochemical oxidation of catechols (2009) J. Iran. Chem. Soc., 6, pp. 448-476 | |
dc.description | Rafiee, M., Nematollahi, D., Electrochemical oxidation of catechols in the presence of cyanoacetone and methyl cyanoacetate (2009) J. Electroanal. Chem., 626, pp. 36-41 | |
dc.description | Teixeira, M.F.S., Bergamini, M.F., Marques, C.M.P., Bocchi, N., Voltammetric determination of L-Dopa using an electrode modified with trinuclear ruthenium ammine complex (Ru-red) supported on Y-type zeolite (2004) Talanta, 63, pp. 1083-1088 | |
dc.description | Tu, Y., Xu, Q., Zou, Q., Yin, Z., Sun, Y., Zhao, Y., Electrochemical behavior of levodopa at multi-wall carbon nanotubes-quantum dots modified glassy carbon electrodes (2007) Anal. Sci., 23, pp. 1321-1324 | |
dc.description | Yaghoubian, H., Karimi-Maleh, H., Khalilzadeh, M.A., Karimi, F., Electrocatalytic oxidation of levodopa at a ferrocene modified carbon nanotube paste electrode (2009) Int. J. Electrochem. Sci., 4, pp. 993-1003 | |
dc.description | Woollins, J.D., (1994) Inorganic experiments, , VCH, Weinheim | |
dc.description | Jaselkis, B., Diehl, H., The polarography of vitamins B12r and B12a (1954) J. Am. Chem. Soc., 76, pp. 4345-4348 | |
dc.description | Silvia, R.H., Gustavo, G.R., Héctor, C.G., Enhanced application of square wave voltammetry with glassy carbon electrode coupled to multivariate calibration tools for the determination of B 6 and B 12 vitamins in pharmaceutical preparations (2003) Talanta, 61, pp. 743-753 | |
dc.description | Lin, M.S., Leu, H.J., Lai, C.H., Development of vitamin B 12 based disposable sensor for dissolved oxygen (2006) Anal. Chim. Acta, 561, pp. 164-170 | |
dc.description | Dong, S., Chi, L., He, P., Wang, Q., Fang, Y., Simultaneous determination of antioxidants at a chemically modified electrode with vitamin B12 by capillary zone electrophoresis coupled with amperometric detection (2009) Talanta, 80, pp. 809-814 | |
dc.description | Iijima, S., Helical microtubules of graphitic carbon (1991) Nature, 354, pp. 56-58 | |
dc.description | Jiang, H., Zhao, Y., Yang, H., Akins, D.L., Synthesis and electrochemical properties of single-walled carbon nanotube-gold nanoparticle composites (2009) Mater. Chem. Phys., 114, pp. 879-883 | |
dc.description | Shih, Y.F., Chen, L.S., Jeng, R.J., Preparation and properties of biodegradable PBS/multi-walled carbon nanotube nanocomposites (2008) Polymer, 49, pp. 4602-4611 | |
dc.description | Zhang, Y., Shen, Y., Han, D., Wang, Z., Song, J., Li, F., Niu, L., Carbon nanotubes and glucose oxidase bionanocomposite bridged by ionic liquid-like unit: Preparation and electrochemical properties (2007) Biosens. Bioelectron., 23, pp. 438-443 | |
dc.description | Rivas, G.A., Rubianes, M.D., Rodríguez, M.C., Ferreyra, N.F., Luque, G.L., Pedano, M.L., Miscoria, S.A., Parrado, C., Carbon nanotubes for electrochemical biosensing (2007) Talanta, 74, pp. 291-307 | |
dc.description | Hu, C., Hu, S., Carbon nanotube-based electrochemical sensors: Principles and applications in biomedical systems (2009) J. Sens., pp. 1-40. , (Review Article) | |
dc.description | Luz, R.C.S., Damos, F.S., Tanaka, A.A., Kubota, L.T., Gushikem, Y., Electrocatalytic activity of 2,3,5,6-tetrachloro-1,4-benzoquinone/multi-walled carbon nanotubes immobilized on edge plane pyrolytic graphite electrode for NADH oxidation (2008) Electrochim. Acta, 53, pp. 4706-4714 | |
dc.description | Luz, R.C.S., Maroneze, C.M., Tanaka, A.A., Kubota, L.T., Gushikem, Y., Damos, F.S., The electrocatalytic activity of a supramolecular assembly of CoTsPc/FeT4MPyP on multi-walled carbon nanotubes towards L-glutathione, and its determination in human erythrocytes (2010) Microchim. Acta, 171, pp. 169-178 | |
dc.description | Pillay, J., Ozoemena, K.I., Efficient electron transport across nickel powder modified basal plane pyrolytic graphite electrode: Sensitive detection of sulfhydryl degradation products of the V-type nerve agents (2007) Electrochem. Comm., 9, pp. 1816-1823 | |
dc.description | (2008), The United States Pharmacopeia - The National Formulary, USP 31 - NF 26, United States Pharmacopeial Convention, RockvilleLee, J., Park, E.J., Choi, J., Hong, J., Shim, S.E., Polyurethane/PEG-modified MWCNT composite film for the chemical vapor sensor application (2010) Synth. Met., 160, pp. 566-574 | |
dc.description | Dhand, C., Arya, S.K., Singh, S.P., Singh, B.P., Datta, M., Malhotra, B.D., Preparation of polyaniline/multiwalled carbon nanotube composite by novel electrophoretic route (2008) Carbon, 46, pp. 1727-1735 | |
dc.description | Borgo, C.A., Lazarin, A.M., Davanzo, C.U., Gushikem, Y., Preparação e caracterização do complexo cobaloxima e sua utilização na construção de um eletrodo modificado. Um experimento eletroquímico no curso de graduação (2003) Quím. Nova, 26, pp. 943-947 | |
dc.description | Bard, A.J., Faulkner, L.R., (2001) Electrochemical Methods: Fundamentals and Applications, , John Wiley & Sons, New York | |
dc.description | Luz, R.C.S., Damos, F.S., Oliveira, A.B., Beck, J., Kubota, L.T., Development of a voltammetric sensor for catechol in nanomolar levels using a modified electrode with Cu(phen) 2(TCNQ) 2 and PLL (2006) Sens. Actuators B, 117, pp. 274-281 | |
dc.description | Laviron, E., Electrochemical reactions with protonations at equilibrium: part II. The 1e, 1 H + reaction (four-member square scheme) for a heterogeneous reaction (1981) J. Electroanal. Chem., 124, pp. 1-7 | |
dc.description | Papouchado, L., Sandford, R.W., Petrie, G., Adams, R.N., Anodic oxidation pathways of phenolic compounds: Part 2. Stepwise electron transfers and coupled hydroxylations (1975) J. Electroanal. Chem., 65, pp. 275-284 | |
dc.description | Recommendations for the definition, estimation and use of the detection limit (1987) Analyst, 112, pp. 199-204. , Analytical Methods Committee | |
dc.description | Teixeira, M.F.S., Marcolino-Júnior, L.H., Fatibello-Filho, O., Dockal, E.R., Bergamini, M.F., An electrochemical sensor for L-Dopa based on oxovanadium-salen thin film electrode applied flow injection system (2007) Sens. Actuators B, 122, pp. 549-555 | |
dc.description | de Melo, H.C., Seleghim, A.P.D., Polito, W.L., Fatibello-Filho, O., Vieira, I.C., Simultaneous differential pulse voltammetric determination of L-Dopa and carbidopa in pharmaceuticals using a carbon paste electrode modified with lead dioxide immobilized in a polyester resin (2007) J. Braz. Chem. Soc., 18, pp. 797-803 | |
dc.description | Quintino, M.S.M., Yamashita, M., Angnes, L., Voltammetric studies and determination of levodopa and carbidopa in pharmaceutical products (2006) Electroanalysis, 18, pp. 655-661 | |
dc.description | Bergamini, M.F., Santos, A.L., Stradiotto, N.R., Zanoni, M.V.B., A disposable electrochemical sensor for the rapid determination of Levodopa (2005) J. Pharm. Biomed. Anal., 39, pp. 54-59 | |
dc.description | Triola, M.F., (2008) Introdução à Estatística, , LTC, Rio de Janeiro | |
dc.language | en | |
dc.publisher | | |
dc.relation | Bioelectrochemistry | |
dc.rights | fechado | |
dc.source | Scopus | |
dc.title | Development Of A Sensor For L-dopa Based On Co(dmg) 2clpy/multi-walled Carbon Nanotubes Composite Immobilized On Basal Plane Pyrolytic Graphite Electrode | |
dc.type | Artículos de revistas | |