Artículos de revistas
Estimated Maximum Oxygen Uptake And Agreement Analysis Between Direct And Predicted Measurement By Different Field Tests [estimativa Do Con Sumo Máximo De Ox Igênio E Análise De Conco Rdância Entre Medida Direta E Predita Por Diferentes Testes De Campo]
Registro en:
Revista Brasileira De Medicina Do Esporte. , v. 19, n. 6, p. 404 - 409, 2013.
15178692
10.1590/S1517-86922013000600005
2-s2.0-84892778862
Autor
Batista M.B.
Cyrino E.S.
Milanez V.F.
e Silva M.J.C.
de Arruda M.
Ronque E.R.V.
Institución
Resumen
Objective: To verify the estimate of aerobic power and agreement between direct and predicted measurement by three different field tests. Methods: The study included 12 subjects (23.1±2.8 years), seven men and five women, who underwent anthropometric measurements of body mass, height and thickness of skin folds. Moreover, the subjects performed a maximal direct test (DT) in a treadmill and three field tests for verification of maximal oxygen uptake (VO2max), in relative values. The field tests performed were: run/walk, 12 minutes by Cooper (COOPER), run/walk a mile (MILE), and 20 meter shuttle run (SR-20M). Data were analyzed by descriptive procedures and for comparisons between the direct measurement and each of the field tests, the paired t test was used. Simple linear regression provided information about the performance of tests and their equations, while the agreement between the methods was made by Bland-Altman analysis, with determination of the t measurement trend. Results: No significant differences were found between the MD and the three field tests. The standard errors of estimation ranged from about 5.8 to 6.0 ml.kg-1.min-1 and the correlation of r = 0.61 - 0.64. The limits of agreement were considered large for the three tests, but without bias and an estimation trend. Conclusions: Despite the similarity between the mean values obtained in comparisons between the field tests and the measurement of reference, the MILE test showed the best performance and agreement to estimate the VO2max. 19 6 404 409 Blair, S.N., Kohl III, H.W., Paffenbarger Jr., R.S., Clark, D.G., Cooper, K.H., Gibbons, L.W., Physical fitness and all-cause mortality. A prospective study of healthy men and women (1989) JAMA, 262, pp. 2395-2401 Lamonte, M.J., Barlow, C.E., Jurga, R., Kampert, J.B., Church, T.S., Blair, S.N., Cardiorespiratory fitness is inversely associated with the incidence of metabolic syndrome: A prospective study of men and women (2005) Circulation, 112, pp. 505-512 Lee, D., Artero, E.G., Sui, X., Blair, S.N., Mortality trends in the general population: The importance of cardiorespiratory fitness (2010) J Psychopharmacology, 24 (SUPPL. 4), pp. 27-35 Astrand, P.O., (1952) Experimental studies of physical work capacity in relation to sex and age, , Copenhagen: Ejnar Munksgaard Basset Jr., D.R., Howley, E.T., Limiting factors for maximum oxygen uptake and determinants of endurance performance (2000) Med Sci Sports Exerc, 32, pp. 70-84 Bassett Jr., D.R., Howley, E.T., Thompson, D.L., King, G.A., Strath, S.J., McLaughlin, J.E., Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system (2001) J Appl Physiol, 91, pp. 218-224 Cyrino, E.S., Okano, A.H., Silva, K.E.S., Altimari, L.R., Dórea, V.R., Zucas, S.M., Aptidão aeróbia e sua relação com os processos de crescimento e maturação (2002) Rev Educ Fís/UEM, 13, pp. 17-26 Grant, J.A., Joseph, A.N., Campagna, P.D., The prediction of VO2max: A comparison of 7 indirect tests of aerobic power (1999) J Strength Cond Res, 13, pp. 356-362 Cyrino, E.S., Papst, R.R., Altimari, L.R., Okano, A.H., Caldeira, L.F.S., Gobbo, L.A., Comparação entre a potência aeróbia estimada por dois testes de campo (2005) Rev Educ Fís/UEM, 16, pp. 171-177 Stickland, M.K., Petersen, S.R., Bouffard, M., Prediction of maximal aerobic power from the 20-m multi-stage shuttle run test (2003) Can J Appl Physiol, 28, pp. 272-282 Léger, L.A., Mercier, D., Gadoury, C., Lambert, J., The multistage 20-meter shuttle run test for aerobic fitness (1988) J Sports Sci, 6, pp. 93-101 Grant, S., Corbett, K., Amjad, A.M., Wilson, J., Aitchison, T., A comparison of methods of predicting maximum oxygen uptake (1995) Br J Sports Med, 29, pp. 147-152 McNaughton, L., Hall, P., Cooley, D., Validation of several methods of estimating maximal oxygen uptake in young men (1998) Percept Mot Skills, 87, pp. 575-584 Duarte, M.F.S., Duarte, C.R., Validade do teste aeróbico de corrida de vai-e-vem de 20 metros (2001) Rev Bras Ciên Mov, 9, pp. 7-14 Atkinson, G., Nevill, A.M., Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine (1998) Sports Med, 26, pp. 217-238 Gordon, C.C., Chumlea, W.C., Roche, A.F., Stature, recumbent length, and weight (1988) Anthropometric standardization reference manual., , In: Lohman TG, Roche AF, Martorell R, editors. Champaign: Human Kinetics Books Harrison, G.G., Buskirk, E.R., Carter, L.J.E., Johnston, F.E., Lohman, T.G., Pollock, M.L., Skinfold thicknesses and measurement technique (1988) Anthropometric standardization reference manual., , In: Lohman TG, Roche AF, Martorell R, editors. Champaign: Human Kinetics Books Cooper, K.H., A means of assessing maximal oxygen uptake (1968) JAMA, 203, pp. 135-138 Margaria, R., Aghemo, P., Limas, F.P., A simple relation between performance in running and maximal aerobic power (1975) J Appl Physiol, 38, pp. 351-352 Léger, L., Lambert, J., A maximal multistage 20-m shuttle run test to predict VO2 max (1982) Eur J Appl Physiol, 49, pp. 1-12 Bland, J.M., Altman, D.G., Statistical methods for assessing agreement between two methods for clinical measurement (1986) Lancet, 8, pp. 307-310 Penry, J.T., Wilcox, A.R., Yun, J., Validity and reliability analysis of Cooper's 12-minute run and the multistage shuttle run in healthy adults (2011) J Strength Cond Res, 25, pp. 597-605 Cureton, K.J., Sloniger, M.A., O'Bannon, J.P., Black, D.M., McCormack, W.P., A generalized equation for prediction of VO2peak from 1-mile run/walk performance (1995) Med Sci Sports Exerc, 27, pp. 445-451 Almeida, J.A., Campbell, C.S.G., Pardono, E., Sotero, R.C., Magalhães, G., Simões, H.G., Validade de equações de predição em estimar o VO2max de brasileiros jovens a partir do desempenho em corrida de 1.600m (2010) Rev Bras Med Esporte, 16, pp. 57-60 Ramsbottom, R., Brewer, J., Williams, C., A progressive shuttle run test to estimate maximal oxygen uptake (1988) Br J Sports Med, 22, pp. 141-144 Ahmaidi, S., Collomp, C., Caillaud, C., Préfaut, C., Maximal and functional aerobic capacity as assessed by two graduated field methods in comparison to laboratory exercise testing moderately trained subjects (1992) Int J Sports Med, 13, pp. 243-248 Sproule, J., Kunalan, C., McNeill, W.H., Validity of 20-MST for predicting VO2max of adult Singaporean athletes (1993) Br J Sports Med, 27, pp. 202-204 Cooper, S.M., Baker, J.S., Tong, R.J., Roberts, E., Hanford, M., The repeatability and criterion related validity of the 20 m multistage fitness test as a predictor of maximal oxygen uptake in active young men (2005) Br J Sports Med, 39, pp. 1-7 Metsios, G.S., Flouris, A.D., Koutedakis, Y., Nevill, A., Criterion-related validity and test-retest reliability of the 20m square shuttle test (2008) J Sci Med Sport, 11, pp. 214-217