dc.creatorTrein M.P.
dc.creatorMundstock K.S.
dc.creatorMaciel L.
dc.creatorRachor J.
dc.creatorGameiro G.H.
dc.date2013
dc.date2015-06-25T19:11:00Z
dc.date2015-11-26T15:08:32Z
dc.date2015-06-25T19:11:00Z
dc.date2015-11-26T15:08:32Z
dc.date.accessioned2018-03-28T22:18:54Z
dc.date.available2018-03-28T22:18:54Z
dc.identifier
dc.identifierDental Press Journal Of Orthodontics. , v. 18, n. 6, p. 117 - 123, 2013.
dc.identifier21769451
dc.identifier10.1590/S2176-94512013000600018
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-84892722680&partnerID=40&md5=88683d3d2fbd5c094cbb61f3cb5e0edf
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/88588
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/88588
dc.identifier2-s2.0-84892722680
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1257682
dc.descriptionObjective: The aim of this study was to assess pain, masticatory performance and swallowing threshold of patients undergoing orthodontic treatment. Methods: Ten patients of both genders (mean age of 17.25 ± 5.21 years), with complete permanent dentition, who underwent orthodontic treatment with fixed appliances were evaluated. The masticatory performance and the swallowing threshold were assessed by patient's individual capacity of fragmenting an artificial test food (Optocal) which was chewed and had the resulting particles processed by a standardized siev- ing method, presenting the median particle size (MPS) of crushed units. The intensity of pain/discomfort during chewing was evaluated by means of a visual analog scale. All tests were performed at the following times: T0 - before activating the orthodontic appliance; T1 - 24 hours after activation, and T2 - 30 days after activation. Results: The results showed a significant increase in pain at T1 (T0 - 0.60 ± 0.70 mm; T1 - 66.2 ± 34.5 mm), returning to baseline values at T2 (3.20 ± 3.82 mm). Masticatory performance was also reduced in T1 (MPS 10.15 ± 1.1 mm2) in comparison to T0 (MPS 7.01 ± 2.9 mm2) and T2 (MPS 6.76 ± 1.3 mm2). However, particle size was not affected in the swallowing threshold test (T0 - 5.47 ± 2.37 mm2; T1 - 6.19 ± 2.05 mm2; T2 - 5.94 ± 2.36 mm2). Conclusion: The orthodontic appliances did not interfere in the size of the particles that would be swallowed, even in the presence of pain. © 2013 Dental Press Journal of Orthodontics.
dc.description18
dc.description6
dc.description117
dc.description123
dc.descriptionKrishnan, V., Orthodontic pain: From causes to management-a review (2007) EurJ Orthod, 29 (2), pp. 170-179
dc.descriptionJones, M., Chan, C., The pain and discomfort experienced during orthodontic treatment: A randomized controlled clinical trial of two initial aligning arch wires (1992) Am J Orthod Dentofacial Orthop, 102 (4), pp. 373-381+18
dc.descriptionPolat, O., Karaman, A.I., Durmus, E., Effects of preoperative ibuprofen and naproxen sodium on orthodontic pain (2005) Angle Orthod, 75 (5), pp. 791-796
dc.descriptionGameiro, G.H., Pereira-Neto, J.S., Magnani, M.B., Nouer, D.F., The Influence of Drugs and Systemic Factors On Orthodontic Tooth Movement (2007), 41 (2), pp. 73-78Kvam, E., Gjerdet, N.R., Bondevik, O., Traumatic ulcers and pain during orthodontic treatment (1987) Community Dent Oral Epidemiol, 15 (2), pp. 104-107+20
dc.descriptionScheurer, P.A., Firestone, A.R., Bürgin, W.B., Perception of pain as a result of orthodontic treatment with fixed appliances (1996) Eur J Orthod, 18 (4), pp. 349-357+21
dc.descriptionvan der Bilt, A., Assessment of mastication with implications for oral rehabilitation: A review (2011) J Oral Rehabil, 38 (10), pp. 754-780
dc.descriptionFontijn-Tekamp, F.A., Slagter, A.P., van der Bilt, A., Van'T, H.M.A., Witter, D.J., Kalk, W., Jansen, J.A., Biting and chewing in overdentures, full dentures, and natural dentitions (2000) J Dent Res, 79 (7), pp. 1519-1524
dc.descriptionvan den Braber, W., van der Bilt, A., van der Glas, H., Rosenberg, T., Koole, R., The influence of mandibular advancement surgery on oral function in retrognathic patients: A 5-year follow-up study (2006) J Oral Maxillofac Surg, 64 (8), pp. 1237-1240+24
dc.descriptionSierpinska, T., Golebiewska, M., Dlugosz, J., Kemona, A., Laszewicz, W., Connection between masticatory efficiency and pathomorphologic changes in gastric mucosa (2007) Quintessence Int, 38 (1), pp. 31-37+25
dc.descriptionPocztaruk, R.L., Frasca, L.C., Rivaldo, E.G., De Fernandes, E.L., Gavião, M.B., Protocol for production of a chewable material for masticatory function tests (Optocal Brazilian version) (2008) Braz Oral Res, 22 (4), pp. 305-310
dc.descriptionBergius, M., Kiliaridis, S., Berggren, U., Pain in orthodontics. A review and discussion of the literature (2000) J Orofac Orthop, 61 (2), pp. 125-137+27
dc.descriptionEnglish, J.D., Buschang, P.H., Throckmorton, G.S., Does malocclusion affect masticatory performance? (2002) Angle Orthod, 72 (1), pp. 21-27+28
dc.descriptionCarlsson, G.E., Masticatory efficiency: The effect of age, the loss of teeth and prosthetic rehabilitation (1984) Int Dent J, 34 (2), pp. 93-97+29
dc.descriptionSalmassian, R., Oesterle, L.J., Shellhart, W.C., Newman, S.M., Comparison of the efficacy of ibuprofen and acetaminophen in controlling pain after orthodontic tooth movement (2009) Am J Orthod Dentofacial Orthop, 135 (4), pp. 516-521
dc.descriptionOng, E., Ho, C., Miles, P., Alignment efficiency and discomfort of three orthodontic archwire sequences: A randomized clinical trial (2011) J Orthod, 38 (1), pp. 32-39
dc.descriptionErdinç, A.M., Dinçer, B., Perception of pain during orthodontic treatment with fixed appliances (2004) Eur J Orthod, 26 (1), pp. 79-85
dc.descriptionTortamano, A., Lenzi, D.C., Haddad, A.C., Bottino, M.C., Dominguez, G.C., Vigorito, J.W., Low-level laser therapy for pain caused by placement of the first orthodontic archwire: A randomized clinical trial (2009) Am J Orthod Dentofacial Orthop, 136 (5), pp. 662-667
dc.descriptionFirestone, A.R., Scheurer, P.A., Bürgin, W.B., Patients anticipation of pain and pain-related side effects, and their perception of pain as a result of orthodontic treatment with fixed appliances (1999) Eur J Orthod, 21 (4), pp. 387-396
dc.descriptionFernandes, L.M., Ogaard, B., Skoglund, L., Pain and discomfort experienced after placement of a conventional or a superelastic NiTi aligning archwire. A randomized clinical trial (1998) J Orofac Orthop, 59 (6), pp. 331-339
dc.descriptionNgan, P., Kess, B., Wilson, S., Perception of discomfort by patients undergoing orthodontic treatment (1989) Am J Orthod Dentofacial Orthop, 96 (1), pp. 47-53
dc.descriptionScott, P., Sherriff, M., Dibiase, A.T., Cobourne, M.T., Perception of discomfort during initial orthodontic tooth alignment using a self-ligating or conventional bracket system: A randomized clinical trial (2008) Eur J Orthod, 30 (3), pp. 227-232
dc.descriptionKrukemeyer, A.M., Arruda, A.O., Inglehart, M.R., Pain and orthodontic treatment (2009) Angle Orthod, 79 (6), pp. 1175-1181
dc.descriptionBrown, D.F., Moerenhout, R.G., The pain experience and psychological adjustment to orthodontic treatment of preadolescents, adolescents, and adults (1991) Am J Orthod Dentofacial Orthop, 100 (4), pp. 349-356
dc.descriptionOliver, R.G., Knapman, Y.M., Attitudes to orthodontic treatment (1985) Br J Orthod, 12 (4), pp. 179-188
dc.descriptionKluemper, G.T., Hiser, D.G., Rayens, M.K., Jay, M.J., Efficacy of a wax containing benzocaine in the relief of oral mucosal pain caused by orthodontic appliances (2002) Am J Orthod Dentofacial Orthop, 122 (4), pp. 359-365
dc.descriptionMurray, G.M., Referred pain, allodynia and hyperalgesia (2009) J Am Dent Assoc, 140 (9), pp. 1122-1124
dc.descriptionHolt, S., Reid, J., Taylor, T.V., Tothill, P., Heading, R.C., Gastric emptying of solids in man (1982) Gut, 23 (4), pp. 292-296
dc.descriptionPera, P., Bucca, C., Borro, R., Bernocco, C., De, L.A., Carossa, S., Influence of mastication on gastric emptying (2002) J Dent Res, 81 (3), pp. 179-181
dc.descriptionFontijn-Tekamp, F.A., van der.Bilt, A., Abbink, J.H., Bosman, F., Swallowing threshold and masticatory performance in dentate adults (2004) Physiol Behav, 83 (3), pp. 431-436
dc.languageen
dc.publisher
dc.relationDental Press Journal of Orthodontics
dc.rightsaberto
dc.sourceScopus
dc.titlePain, Masticatory Performance And Swallowing Threshold In Orthodontic Patients
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución