dc.creatorLeite M.A.
dc.creatorPereira M.C.
dc.creatorCostallat L.T.L.
dc.creatorVillalba W.O.
dc.creatorMoreira M.M.
dc.creatorPaschoal I.A.
dc.date2014
dc.date2015-06-25T18:04:14Z
dc.date2015-11-26T15:06:37Z
dc.date2015-06-25T18:04:14Z
dc.date2015-11-26T15:06:37Z
dc.date.accessioned2018-03-28T22:17:03Z
dc.date.available2018-03-28T22:17:03Z
dc.identifier
dc.identifierRevista Brasileira De Reumatologia. Elsevier Editora Ltda, v. 54, n. 3, p. 192 - 199, 2014.
dc.identifier4825004
dc.identifier10.1016/j.rbre.2014.02.017
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-84904688161&partnerID=40&md5=7c7b45b950cf0a0e16056b7b1526db73
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/88144
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/88144
dc.identifier2-s2.0-84904688161
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1257266
dc.descriptionObjective: Evaluate SLE stable patients, without overt respiratory compromise, by means of 6MWT. Casuistic and methods: Forty-five stable SLE patients were enrolled. The ATS/ERS protocol for 6MWT, was used and two parameters with cut-off points were chosen. Results: Forty-two patients were women. The mean age was 39 ± 11.4 years; mean duration of disease, 121 ± 93.1 months; mean value of MRC, 2 ± 0; mean FVC, 85.9 ± 34.2%; mean FEV1, 67.5 ± 21.6%; mean MIP, 82 ± 58.4%; mean MEP, 78 ± 37.3%; mean heart rate at rest, 75 ± 12.8 bpm; mean respiratory rate at rest, 19 ± 5.3 bpm; mean 6MWD, 478 ± 82 m; mean SpO2 at rest was 98 ± 0.8%; mean fall in SpO2, 4 ± 6 points. When the study population was divided according to the 400-m walk distance cut-off value, the heart rate immediately before the test was significant lower in those participants who walked less than 400 m (p = 0.0043), just like the value of Borg scale (p = 0.0036); according to the presence of saturation ≥ 4, heart rate at the end of the test was significantly higher in those participants who were showing desaturation (p = 0.0170); MEP (p = 0.0282) and 6MWD (p = 0.0291) were significantly lower, and MIP showed a tendency towards being smaller (p = 0.0504). FVC < normal inferior limit was significantly associated with the group with desaturation (p = 0.0274). Conclusion: Compared to 6MWD, desaturation was better suited to find the patients with the most compromised indexes in respiratory function tests. © 2014 Sociedade Brasileira de Reumatologia. Published by Elsevier Editora Ltda. All rights reserved.
dc.description54
dc.description3
dc.description192
dc.description199
dc.descriptionRus, V., Maury, E.E., Hochberg, M.C., The epidemiology of systemic lupus erythematosus (2007) Dubois lupus erythematosus, pp. 34-44. , Wallace DJ, Hahn BH, editors. 7th ed. Filadélfia: Lippincott Williams & Wilkins;
dc.descriptionSato, E.I., Natour, J., Martinelli, V.P.L., Assis, L.S.S., Farão, S.R., Medeiros, E.L., Seguimento clínico e laboratorial de 132 pacientes com lúpus eritematoso sistêmico (1991) Rev Bras Reumatol, 31, pp. 57-62
dc.descriptionCostallat, L.T.L., Coimbra, A.M.V., Lúpus eritematoso sistêmico: análise clínica e laboratorial de 272 pacientes em um hospital universitario: 1973-1982 (1995) Rev Bras Reumatol, 35, pp. 23-29
dc.descriptionRothfield, N.F., Systemic lupus erythematosus: clinical aspects and treatment (1993), pp. 1155-1177. , McCarty DJ & Koopman WJ. Arthritis and allied conditions - a textbook of rheumatology, 12. ed. Philadelphia: Lea & FebigerBelmont, H.M., Abramson, S.B., Lie, J.T., Pathology and pathogenesis of vascular injury in systemic lupus erythematosus Interactions of inflammatory cells and activated endothelium. (1996) Arthritis Rheum, 39, pp. 9-22
dc.descriptionKrishnaswamy, G., Kelley, J., Yerra, L., Smith, J.K., Chi, D.S., Human endothelium as a source of multifunctional cytokines: molecular regulation and possible role in human disease (1999) J Interferon Cytokine Res, 19, pp. 91-104
dc.descriptionHochberg, M.C., Updating the American College of Rheumatology revised criteria for the classification of systemic lupus erythematosus (1997) Arthritis Rheum, 40, p. 1725
dc.descriptionATS., statement: guidelines for the six-minute walk, test (2002) Am, J., Respir Crit Care Med, 166, pp. 111-117
dc.descriptionPoulain, M., Durand, F., Palomba, B., Ceugniet, F., Desplan, J., Varray, A., 6-minute walk testing is more sensitive than maximal incremental cycle testing for detecting oxygen desaturation in patients with COPD (2003) Chest, 123, pp. 1401-1407
dc.descriptionKawut, S.M., Horn, E.M., Berekashvili, K.K., Garofano, R.P., Goldsmith, R.L., Widlitz, A.C., New predictors of outcome in idiopathic pulmonary arterial hypertension (2005) Am J Cardiol, 95, pp. 199-203
dc.descriptionMiyamoto, S., Nagaya, N., Satoh, T., Kyotani, S., Sakamaki, F., Fujita, M., Clinical correlates and prognostic significance of six-minute walk test in patients with primary pulmonary hypertension Comparison with cardiopulmonary exercise testing (2000) Am J Respir Crit Care Med, 161, pp. 487-492
dc.descriptionPaciocco, G., Martinez, F.J., Bossone, E., Pielsticker, E., Gillespie, B., Rubenfire, M., Oxygen desaturation on the six-minute walk test and mortality in untreated primary pulmonary hypertension (2001) Eur Respir J, 17, pp. 647-652
dc.descriptionVillalba, W.O., Sampaio-Barros, P.D., Pereira, M.C., Cerqueira, E.M., Leme Jr, C.A., Marques-Neto, J.F., Six-minute walk test for the evaluation of pulmonary disease severity in scleroderma patients (2007) Chest, 131, pp. 217-222
dc.descriptionRostagno, C., Olivo, G., Comeglio, M., Boddi, V., Banchelli, M., Galanti, G., Prognostic value of 6-minute walk corridor test in patients with mild to moderate heart failure: comparison with other methods of functional evaluation (2003) Eur J Heart Fail, 5, pp. 247-252
dc.descriptionPereira, C.A., Diretrizes para Testes de Função Pulmonar (2002) J Bras Pneumologia, p. 28
dc.descriptionKnudson, R.J., Lebowitz, M.D., Holberg, C.J., Burrows, B., Changes in the normal maximal expiratory flow-volume curve with growth and aging (1983) Am Rev Respir Dis, 127, pp. 725-734
dc.descriptionII Consenso de, DPOC. (2004) J Bras Pneumol, 30, pp. s1-s42
dc.descriptionAmerican Thoracic Society/European Respiratory, Society. ATS/ERS Statement on respiratory muscle testing (2002) Am J Respir Crit Care Med, 166, pp. 518-624
dc.descriptionNeder, J.A., Andreoni, S., Lerario, M.C., Nery, L.E., Reference values for lung function tests II. Maximal respiratory pressures and voluntary ventilation (1999) Braz J Med Biol Res, 32, pp. 719-727
dc.descriptionPrefaut, C., Durand, F., Mucci, P., Caillaud, C., Exercise-induced arterial hypoxaemia in athletes: a review (2000) Sports Med, 30, pp. 47-61
dc.descriptionSoares, M.R., Pereira, C.A., Six-minute walk test: reference values for healthy adults in Brazil (2011) J Bras Pneumol, 37, pp. 576-583
dc.descriptionCote, C.G., Casanova, C., Marín, J.M., Lopez, M.V., Pinto-Plata, V., de Oca, M.M., Validation and comparison of reference equations for the 6-min walk distance test (2008) Eur Respir J, 31, pp. 571-578
dc.descriptionKadikar, A., Maurer, J., Kesten, S., The six-minute walk test: a guide to assessment for lung transplantation (1997) J Heart Lung Transplant, 16, pp. 313-319
dc.descriptionProvencher, S., Chemla, D., Hervé, P., Sitbon, O., Humbert, M., Simonneau, G., Heart rate responses during the 6-minute walk test in pulmonary arterial hypertension (2006) Eur Respir J, 27, pp. 114-120
dc.descriptionFrost, A.E., Langleben, D., Oudiz, R., Hill, N., Horn, E., McLaughlin, V., The 6-min walk test (6MW) as an efficacy endpoint in pulmonary arterial hypertension clinical trials: demonstration of a ceiling effect (2005) Vascul Pharmacol, 43, pp. 36-39
dc.descriptionLama, V.N., Flaherty, K.R., Toews, G.B., Colby, T.V., Travis, W.D., Long, Q., Prognostic value of desaturation during a 6-minute walk test in idiopathic interstitial pneumonia (2003) Am J Respir Crit Care Med, 168, pp. 1084-1090
dc.descriptionGibson, C.J., Edmonds, J.P., Hughes, G.R., Diaphragm function and lung involvement in systemic lupus erythematosus (1977) Am J Med, 63, pp. 926-932
dc.descriptionLaroche, C.M., Mulvey, D.A., Hawkins, P.N., Walport, M.J., Strickland, B., Moxham, J., Diaphragm strength in the shrinking lung syndrome of systemic lupus erythematosus (1989) Q J Med, 71, pp. 429-439
dc.descriptionEaton, T., Young, P., Milne, D., Wells, A.U., Six-minute walk, maximal exercise tests: reproducibility in fibrotic interstitial pneumonia (2005) Am J Respir Crit Care Med, 171, pp. 1150-1157
dc.descriptionNielsen, H.B., Arterial desaturation during exercise in man: implication for O2 uptake and work capacity (2003) Scand J Med Sci Sports, 13, pp. 339-358
dc.descriptionNielsen, H.B., Boesen, M., Secher, N.H., Near-infrared spectroscopy determined brain and muscle oxygenation during exercise with normal and resistive breathing (2001) Acta Physiol Scand, 171, pp. 63-70
dc.descriptionKikuchi, K., Kubo, M., Kadono, T., Yazawa, N., Ihn, H., Tamaki, K., Serum concentrations of vascular endothelial growth factor in collagen diseases (1998) Br J Dermatol, 139, pp. 1049-1051
dc.descriptionKuryliszyn-Moskal, A., Klimiuk, P.A., Sierakowski, S., Ciołkiewicz, M., Vascular endothelial growth factor in systemic lupus erythematosus: relationship to disease activity, systemic organ manifestation, and nailfold capillaroscopic abnormalities (2007) Arch Immunol Ther Exp (Warsz), 55, pp. 179-185
dc.descriptionGoldie, R.G., Endothelins in health and disease: an overview (1999) Clin Exp Pharmacol Physiol, 26, pp. 145-148
dc.descriptionBalsamo, S., Nascimento Dda, C., Tibana, R.A., De Santana, F.S., Da Mota, L.M., Dos Santos-Neto, L.L., The quality of life of patients with lupus erythematosus influences cardiovascular capacity in 6-minute walk test (2013) Rev Bras Reumatol, 53, pp. 75-87
dc.languageen
dc.publisherElsevier Editora Ltda
dc.relationRevista Brasileira de Reumatologia
dc.rightsfechado
dc.sourceScopus
dc.titleEvaluation Of Respiratory Impairment In Patients With Systemic Lupus Erythematosus With The Six-minute Walk Test
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución