dc.creator | Rocha E.P. | |
dc.creator | Anchieta R.B. | |
dc.creator | de Almeida E.O. | |
dc.creator | Freitas A.C. | |
dc.creator | Martini A.P. | |
dc.creator | Sotto-Maior B.S. | |
dc.creator | Luersen M.A. | |
dc.creator | Ko C.C. | |
dc.date | 2015 | |
dc.date | 2015-06-25T12:52:17Z | |
dc.date | 2015-11-26T15:04:31Z | |
dc.date | 2015-06-25T12:52:17Z | |
dc.date | 2015-11-26T15:04:31Z | |
dc.date.accessioned | 2018-03-28T22:15:20Z | |
dc.date.available | 2018-03-28T22:15:20Z | |
dc.identifier | | |
dc.identifier | Computer Methods In Biomechanics And Biomedical Engineering. Taylor And Francis Ltd., v. 18, n. 16, p. 1744 - 1752, 2015. | |
dc.identifier | 10255842 | |
dc.identifier | 10.1080/10255842.2014.951927 | |
dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-84923457781&partnerID=40&md5=b9ea09c062a1ca9b2b26f2ffeaeed284 | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/85375 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/85375 | |
dc.identifier | 2-s2.0-84923457781 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1256865 | |
dc.description | Veneer fracture is the most common complication in zirconia-based restorations. The aim of this study was to evaluate the mechanical behavior of a zirconia-based crown in a lower canine tooth supporting removable partial denture (RPD) prosthesis, varying the bond quality of the veneer/coping interface. Microtomography (μCT) data of an extracted left lower canine were used to build the finite element model (M) varying the core material (gold core – MAu; zirconia core – MZi) and the quality of the veneer/core interface (complete bonded – MZi; incomplete bonded – MZi-NL). The incomplete bonding condition was only applied for zirconia coping by using contact elements (Target/Contact) with 0.3 frictional coefficients. Stress fields were obtained using Ansys Workbench 10.0. The loading condition (L = 1 N) was vertically applied at the base of the RPD prosthesis metallic support towards the dental apex. Maximum principal (σmax) and von Mises equivalent (σvM) stresses were obtained. The σmax (MPa) for the bonded condition was similar between gold and zirconia cores (MAu, 0.42; MZi, 0.40). The incomplete bonded condition (MZi-NL) raised σmax in the veneer up to 800% (3.23 MPa) in contrast to the bonded condition. The peak of σvM increased up to 270% in the MZi-NL. The incomplete bond condition increasing the stress in the veneer/zirconia interface. | |
dc.description | 18 | |
dc.description | 16 | |
dc.description | 1744 | |
dc.description | 1752 | |
dc.description | Aboushelib, M.N., Kleverlaan, C.J., Feilzer, A.J., Effect of zirconia type on its bond strength with different veneer ceramics (2008) J Prosthodont, 17, pp. 401-408 | |
dc.description | Adanir, N., Belli, S., Stress analysis of a maxillary central incisor restored with different posts (2007) Eur J Dent, 1, pp. 67-71 | |
dc.description | Anchieta, R.B., Rocha, E.P., Ko, C.C., Sundfeld, R.H., Martin Junior, M., Archangelo, C.M., Localized mechanics of dentin self-etching adhesive system (2007) J Appl Oral Sci, 15, pp. 321-326 | |
dc.description | Anusavice, K.J., Reducing the failure potential of ceramic-based restorations. Part 2: ceramic inlays, crowns, veneers, and bridges (1997) Gen Dent., 45 (1), pp. 30-35 | |
dc.description | Asmussen, E., Peutzfeldt, A., Sahafi, A., Finite element analysis of stresses in endodontically treated, dowel-restored teeth (2005) J Prosthet Dent, 94, pp. 321-329 | |
dc.description | Carracho, J.F., Razzoog, M.E., Removable partial denture abutments restored with all-ceramic surveyed crowns (2006) Quintessence Int, 37, pp. 283-288 | |
dc.description | Cattaneo, P.M., Dalstra, M., Melsen, B., The finite element method: a tool to study orthodontic tooth movement (2005) J Dent Res, 84, pp. 428-433 | |
dc.description | Coelho, P.G., Bonfante, E.A., Silva, N.R., Rekow, E.D., Thompson, V.P., Laboratory simulation of Y-TZP all-ceramic crown clinical failures (2009) J Dent Res, 88, pp. 382-386 | |
dc.description | Couegnat, G., Fok, S.L., Cooper, J.E., Qualtrough, A.J., Structural optimization of dental restorations using the principle of adaptive growth (2006) Dent Mater, 22, pp. 3-12 | |
dc.description | Dejak, B., Mlotkowski, A., Three-dimensional finite element analysis of strength and adhesion of composite resin versus ceramic inlays in molars (2008) J Prosthet Dent, 99, pp. 131-140 | |
dc.description | Denry, I., Kelly, J.R., State of the art of zirconia for dental applications (2008) Dent Mater, 24, pp. 299-307 | |
dc.description | Dittmer, M.P., Borchers, L., Stiesch, M., Kohorst, P., Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process (2009) Acta Biomater, 5, pp. 3231-3239 | |
dc.description | Farga-Niñoles, I., Agustín-Panadero, R., Román-Rodriguez, J.L., Solá-Ruíz, M.F., Granell-Ruíz, M., Fons-Font, A., Fractographic study of the behavior of different ceramics veneers on full coverage crowns in relation to supporting core materials (2013) J Clin Exp Dent, 5 (5), pp. 260-266 | |
dc.description | Fischer, J., Stawarzcyk, B., Trottmann, A., Hämmerle, C.H., Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites (2009) Dent Mater, 25, pp. 419-423 | |
dc.description | Guo, X., On the degradation of zirconia ceramics during low-temperature annealing in water or water vapor (1999) J Phys Chem Solids, 60, pp. 539-546 | |
dc.description | Hickel, R., Manhart, J., Longevity of restorations in posterior teeth and reasons for failure (2001) J Adhes Dent., 3 (1), pp. 45-64 | |
dc.description | Huang, H.L., Hsu, J.T., Fuh, L.J., Tu, M.G., Ko, C.C., Shen, Y.W., Bone stress and interfacial sliding analysis of implant design on an immediately loaded maxillary implant: a non-linear finite element study (2008) J Dent, 36, pp. 409-417 | |
dc.description | Kancyper, S., Sierraalta, M., Razzoog, M.E., All-ceramic surveyed crowns for removable partial denture abutments (2000) J Prosthet Dent, 84, pp. 400-402 | |
dc.description | Kohorst, P., Dittmer, M.P., Borchers, L., Stiesch-Scholz, M., Influence of cyclic fatigue in water on the load-bearing capacity of dental bridges made of zirconia (2008) Acta Biomater., 4 (5), pp. 1440-1447 | |
dc.description | Lanza, L., Aversa, R., Rengo, S., Apicella, D., Apicella, A., 3D FEA of cemented steel, glass and carbon posts in a maxillary incisor (2005) Dent Mater, 21, pp. 709-715 | |
dc.description | Lin, C.L., Chang, C.H., Wang, C.H., Ko, C.C., Lee, H.E., Numerical investigation of the factors effecting interfacial stresses in an MOD restored tooth by auto-meshed finite element method (2001) J Oral Rehabil, 28, pp. 517-525 | |
dc.description | Magne, P., Perakis, N., Belser, U.C., Krejci, I., Stress distribution of inlay-anchored adhesive fixed partial dentures: a finite element analysis of the influence of restorative materials and abutment preparation design (2002) J Prost Dent, 87, pp. 516-527 | |
dc.description | Marchack, B.W., Chen, L.B., Marchack, C.B., Futatsuki, Y., Fabrication of an all-ceramic abutment crown under an existing removable partial denture using CAD/CAM technology (2007) J Prosthet Dent, 98, pp. 478-482 | |
dc.description | Martini, A.P., Anchieta, R.B., Rocha, E.P., Freitas Junior, A.C., Jr., Almeida, E.O., Sundfeld, R.H., Luersen, M.A., Influence of voids in the hybrid layer based on self-etching adhesive systems: a 3-D FE analysis (2009) J Appl Oral Sci, 17, pp. 19-26 | |
dc.description | McCracken, W.L., Contemporary partial denture designs. 1958 (2004) J Prosthet Dent, 92, pp. 409-417 | |
dc.description | O'Brien, W.J., (2002) Dental materials and their selection, , 3rd ed, Chicago (IL): Quintessence | |
dc.description | Proos, K.A., Swain, M.V., Ironside, J., Steven, G.P., Finite element analysis studies of an all-ceramic crown on a first premolar (2002) Int J Prosthodont, 15, pp. 404-412 | |
dc.description | Rafferty, B.T., Bonfante, E.A., Janal, M.N., Silva, N.R., Rekow, E.D., Thompson, V.P., Coelho, P.G., Biomechanical evaluation of an anatomically correct all-ceramic tooth-crown system configuration: core layer multivariate analysis incorporating clinically relevant variables (2010) J Biomech Eng, 132 (5), p. 051001 | |
dc.description | Raigrodski, A.J., Chiche, G.J., Potiket, N., Hochstedler, J.L., Mohamed, S.E., Billiot, S., Mercante, D.E., The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study (2006) J Prosthet Dent, 96, pp. 237-244 | |
dc.description | Rekow, D., Thompson, V.P., Engineering long term clinical success of advanced ceramic prostheses (2007) J Mater Sci Mater Med, 18, pp. 47-56 | |
dc.description | Rekow, E.D., Harsono, M., Janal, M., Thompson, V.P., Zhang, G., Factorial analysis of variables influencing stress in all-ceramic crowns (2006) Dent Mater, 22, pp. 125-132 | |
dc.description | Rocha, E.P., Anchieta, R.B., Freitas, A.C., Jr., de Almeida, E.O., Cattaneo, P.M., Chang Ko, C., Mechanical behavior of ceramic veneer in zirconia-based restorations: a 3-dimensional finite element analysis using microcomputed tomography data (2011) J Prosthet Dent, 105, pp. 14-20 | |
dc.description | Sadowsky, S.J., An overview of treatment considerations for esthetic restorations: a review of the literature (2006) J Prosthet Dent, 96, pp. 433-442 | |
dc.description | Sailer, I., Fehér, A., Filser, F., Gauckler, L.J., Lüthy, H., Hämmerle, C.H., Five-year clinical results of zirconia frameworks for posterior fixed partial dentures (2007) Int J Prosthodont, 20, pp. 383-388 | |
dc.description | Sailer, I., Fehér, A., Filser, F., Lüthy, H., Gauckler, L.J., Schärer, P., Hämmerle, C.H., Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up (2006) Quintessence Int, 37, pp. 685-693 | |
dc.description | Sailer, I., Pjetursson, B.E., Zwahlen, M., Hämmerle, C.H., A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses (2007) Clin Oral Implants Res, 18, pp. 86-96 | |
dc.description | Santana, T., Zhang, Y., Guess, P., Thompson, V.P., Rekow, E.D., Silva, N.R., Off-axis sliding contact reliability and failure modes of veneered alumina and zirconia (2009) Dent Mater, 25, pp. 892-898 | |
dc.description | Shillingburg, H.T., Hobo, S., Whitsett, L.D., (1997) Fundamentals of fixed prosthodontics, , 3rd ed, Chicago (IL): Quintessence, 582 p | |
dc.description | Sorrentino, R., Aversa, R., Ferro, V., Auriemma, T., Zarone, F., Ferrari, M., Apicella, A., Three-dimensional finite element analysis of strain and stress distributions in endodontically treated maxillary central incisors restored with different post, core and crown materials (2007) Dent Mater, 23, pp. 983-993 | |
dc.description | Taskonak, B., Yan, J., Mecholsky, J.J., Jr., Sertgöz, A., Koçak, A., Fractographic analyses of zirconia-based fixed partial dentures (2008) Dent Mater, 24, pp. 1077-1082 | |
dc.description | Thongthammachat-Thavornthanasarn, S., Restoration of the partially dentate patient with conventional fixed and removable prostheses (2007) J Prosthodont, 16, pp. 282-287 | |
dc.description | Tillitson, E.W., Craig, R.G., Peyton, F.A., Friction and wear of restorative dental materials (1971) J Dent Res, 50, pp. 149-154 | |
dc.description | Tinschert, J., Natt, G., Mautsch, W., Augthun, M., Spiekermann, H., Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study (2001) Int J Prosthodont, 14, pp. 231-238 | |
dc.description | Walter, M., Reppel, P.D., Böning, K., Freesmeyer, W.B., Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures (1999) J Oral Rehabil, 26, pp. 91-96 | |
dc.description | Yettram, A.L., Wright, K.W., Houston, W.J., Centre of rotation of a maxillary central incisor under orthodontic loading (1977) Br J Orthod, 4, pp. 23-27 | |
dc.language | en | |
dc.publisher | Taylor and Francis Ltd. | |
dc.relation | Computer Methods in Biomechanics and Biomedical Engineering | |
dc.rights | fechado | |
dc.source | Scopus | |
dc.title | Zirconia-based Dental Crown To Support A Removable Partial Denture: A Three-dimensional Finite Element Analysis Using Contact Elements And Micro-ct Data | |
dc.type | Artículos de revistas | |