dc.creatorTubino M.
dc.creatorQueiroz C.A.R.
dc.date2007
dc.date2015-06-30T18:40:45Z
dc.date2015-11-26T15:02:01Z
dc.date2015-06-30T18:40:45Z
dc.date2015-11-26T15:02:01Z
dc.date.accessioned2018-03-28T22:12:59Z
dc.date.available2018-03-28T22:12:59Z
dc.identifier
dc.identifierAnalytica Chimica Acta. , v. 600, n. 1-2 SPEC. ISS., p. 199 - 204, 2007.
dc.identifier32670
dc.identifier10.1016/j.aca.2006.11.034
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-34548864409&partnerID=40&md5=6153d5c1fffa71bad9870782fffe115d
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/104307
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/104307
dc.identifier2-s2.0-34548864409
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1256387
dc.descriptionFlow injection (FI) methodology, using diffuse reflectance in the visible region of the spectrum, for the analysis of nickel, precipitated in the form of dimethylglyoximate, is presented. A reflectance cell, constructed in polytetrafluoroethylene, using a LED (light emitting diode) as light source and a LDR (light dependent resistor) as detector, is described. The analytical signal (S) correlates with nickel concentration (C) between 1.6 × 10-4 and 6.6 × 10-4 mol L-1. This correlation is described by the equation S = -1.108 + 3.314 × 104C - 2.081 × 107C2 (r = 0.9996). The experimentally observed limit of detection is about 1.3 × 10-4 mol L-1, as in lower concentrations the formation of precipitate is not observed. The experimental quantitation limit is about 1.6 × 10-4 mol L-1. The mean R.S.D. (relative standard deviation) is about 2.7%. Samples containing nickel were analyzed and the results obtained in this method were compared with those of other methods using the statistical Student's t-test. © 2006 Elsevier B.V. All rights reserved.
dc.description600
dc.description1-2 SPEC. ISS.
dc.description199
dc.description204
dc.descriptionTubino, M., Rossi, A.V., de Magalhães, M.E.A., (1997) Anal. Lett., 30, p. 271
dc.descriptionMatias, F.A.A., Vila, M.M.D.C., Tubino, M., (2004) J. Braz. Chem. Soc., 15, p. 327
dc.descriptionGotardo, M.A., Gigante, A.C., Pezza, L., Pezza, H.R., (2004) Talanta, 64, p. 361
dc.descriptionMatias, F.A.A., Vila, M.M.D.C., Tubino, M., (2003) Sens. Actuators B Chem., 88, p. 60
dc.descriptionGhauch, A., Turnar, C., Fachinger, C., Rima, J., Charef, A., Suptil, J., Martin-Bouyer, M., (2000) Chemosphere, 40, p. 1327
dc.descriptionGhauch, A., Rima, J., Charef, A., Suptil, J., Fachinger, C., Martin-Bouyer, M., (1999) Talanta, 48, p. 385
dc.descriptionKompany-Zareh, M., Mansourian, M., Ravaee, F., (2002) Anal. Chim. Acta, 471, p. 97
dc.descriptionRaimundo, I.A., Narayanaswamy, R., (2003) Sens. Actuators B Chem., 90 (SI), p. 189
dc.descriptionTubino, M., de Souza, R.L., (2006) Talanta, 68, p. 776
dc.descriptionMalcik, N., Caglar, P., Narayanaswamy, R., (2000) Quim. Anal., 19 (SUPPL. 1), p. 94
dc.descriptionRuzicka, J., Hansen, E.H., (1985) Anal. Chim. Acta, 173, p. 3
dc.descriptionRuzicka, J., Pollema, C.H., Scudder, K.M., (1993) Anal. Chem., 65, p. 3566
dc.descriptionRuzicka, J., (1995) Anal. Chim. Acta, 308, p. 14
dc.descriptionKuswandi, B., Narayanaswamy, R., (1998) Anal. Lett., 31, p. 395
dc.descriptionTaylor, R.H., Grate, J.W., (1995) Talanta, 42, p. 257
dc.descriptionMiró, M., Frenzel, W., Estela, J.M., Cerdà, V., (2001) Analyst, 126, p. 1740
dc.descriptionAlbero, M.I., Ortuno, J.A., Garcia, M.S., Sánchez-Pedreño, C., Expósito, R., (2002) J. Pharm. Biomed. Anal., 29, p. 779
dc.descriptionYusof, N.A., Ahmad, M., (2003) Sens. Actuators B Chem., 94, p. 201
dc.descriptionPons, C., Forteza, R., Cerdà, V., (2005) Anal. Chim. Acta, 528, p. 197
dc.descriptionFerrer, L., de Armas, G., Miró, M., Estela, J.M., Cerdà, V., (2005) Talanta, 68, p. 343
dc.descriptionLee, J.H., Han, M.A., Kang, S.W., Seo, S.S., Hwang, H., (2005) Bull. Korean Chem. Soc., 26, p. 36
dc.descriptionLiu, L.H., Dasgupta, P.K., (1995) Anal. Chem., 67, p. 4221
dc.descriptionTubino, M., Barros, F.G., (1991) Quim. Nova, 14, p. 49
dc.descriptionRodrigues, T.C., Tubino, M., Godinho, O.E.S., Neto, G.O., (2001) Anal. Sci., 17, p. 629
dc.descriptionEckschlager, K., (1972) Errors, Measurement and Results in Chemical Analysis, , Van Nostrand Reinhold, London p. 107
dc.languageen
dc.publisher
dc.relationAnalytica Chimica Acta
dc.rightsfechado
dc.sourceScopus
dc.titleFlow Injection Visible Diffuse Reflectance Quantitative Analysis Of Nickel
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución