dc.creatordi Hipolito V.
dc.creatorAlonso R.C.B.
dc.creatorCarrilho M.R.O.
dc.creatorNetto C.A.
dc.creatorSinhoreti M.A.C.
dc.creatorde Goes M.F.
dc.date2011
dc.date2015-06-30T20:35:47Z
dc.date2015-11-26T14:51:50Z
dc.date2015-06-30T20:35:47Z
dc.date2015-11-26T14:51:50Z
dc.date.accessioned2018-03-28T22:03:38Z
dc.date.available2018-03-28T22:03:38Z
dc.identifier
dc.identifierBrazilian Dental Journal. , v. 22, n. 2, p. 122 - 128, 2011.
dc.identifier1036440
dc.identifier10.1590/S0103-64402011000200006
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-79956315740&partnerID=40&md5=84820ec133e0ef89eb0e259bf0e5cf63
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/108558
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/108558
dc.identifier2-s2.0-79956315740
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1254619
dc.descriptionThis study evaluated the bonding characteristics to ground and unground enamel obtained with different strategies. For this purpose, 24 sound third-molars were bisected mesiodistally to obtain tooth halves. A flat enamel area was delimited in the tooth sections, which were randomly distributed into 8 groups (n=6), according to the enamel condition (ground and unground) and adhesive system (Adper Single Bond 2 - SB2; Adper Prompt L-Pop - PLP; Adper Prompt - AD; Clearfil SE Bond - SE). Each system was applied according manufacturers' instructions and a 6-mm-high resin composite "crown" was incrementally built up on bonded surfaces. Hourglass-shaped specimens with 0.8 mm2 cross-section were produced. Microtensile bond strength (μTBS) was recorded and the failure patterns were classified. Results were analyzed by two-way ANOVA and Tukey's test (α=0.05). There were no statistically significant differences among the μTBS values of SB2, PLP and AD (p>0.05). SE values were significantly lower (p<0.05) than those of SB2 and PLP, but not different from those of AD (p>0.05). There was prevalence of cohesive failure within enamel, adhesive system and resin composite for SB2. The self-etch systems produced higher incidence of cohesive failures in the adhesive system. Enamel condition did not determine significant differences on bonding characteristics for the same bonding system. In conclusion, the bonding systems evaluated in this study resulted in specific μTBS and failure patterns due to the particular interaction with enamel.
dc.description22
dc.description2
dc.description122
dc.description128
dc.descriptionGoes, M.F., Sinhoreti, M.A., Consani, S., Silva, M.A., Morphological effect of the type, concentration and etching time of acid solutions on enamel and dentin surfaces (1998) Braz Dent J, 9, pp. 3-10
dc.descriptionSwift Jr., E.J., Perdigão, J., Heymann, H.O., Bonding to enamel and dentin: A brief history and state of the art, 1995 (1995) Quintessence Int, 26, pp. 95-110
dc.descriptionvan Meerbeek, B., Yoshihara, K., Yoshida, Y., de Mine, A.J.M.K.L.V.L., State of the art of self-etch adhesives (2011) Dent Mater, 27, pp. 17-28
dc.descriptionMine, A., de Munck, J., Vivan Cardoso, M., van Landuyt, K.L., Poitevin, A., Kuboki, T., Enamel-smear compromises bonding by mild self-etch adhesives (2010) J Dent Res, 89, pp. 1505-1509
dc.descriptionKanemura, N., Sano, H., Tagami, J., Tensile bond strength to and SEM evaluation of ground and intact enamel surfaces (1999) J Dent, 27, pp. 523-530
dc.descriptionPivetta, M.R., Moura, S.K., Barroso, L.P., Lascala, A.C., Reis, A., Loguercio, A.D., Bond strength and etching pattern of adhesive systems to enamel: Effects of conditioning time and enamel preparation (2008) J Esthet Restor Dent, 20, pp. 322-335
dc.descriptionPashley, D.H., Tay, F.R., Aggressiveness of contemporary self-etching adhesives. Part II: Etching effects on unground enamel (2001) Dent Mater, 17, pp. 430-444
dc.descriptionDi Hipólito, V., de Goes, M.F., Carrilho, M.R., Chan, D.C., Daronch, M., Sinhoreti, M.A., SEM evaluation of contemporary self-etching primers applied to ground and unground enamel (2005) J Adhes Dent, 7, pp. 203-211
dc.descriptionMjor, I.A., Moorhead, J.E., Dahl, J.E., Reasons for replacement of restorations in permanent teeth in general dental practice (2000) Int Dent J, 50, pp. 361-366
dc.descriptionBurrow, M.F., Tyas, M.J., 1-year clinical evaluation of one-step in non-carious cervical lesions (1999) Am J Dent, 12, pp. 283-285
dc.descriptionOpdam, N.J., Roeters, F.J., Feilzer, A.J., Verdonschot, E.H., Marginal integrity and postoperative sensitivity in Class 2 resin composite restorations in vivo (1998) J Dent, 26, pp. 555-562
dc.descriptionPerdigão, J., Lambrechtes, P., van Meerbee, K.B., Vanherle, G., Lopes, A.L., Filed emission SEM comparison of four postfixation drying techniques for human dentin (1995) J Biomed Mater Res, 290, pp. 1111-1120
dc.descriptionSano, H., Shono, T., Sonoda, H., Takatsu, T., Ciucchi, B., Carvalho, R., Relationship between surface area for adhesion and tensile bond strength. Evaluation of a micro-tensile bond test (1994) Dent Mater, 10, pp. 236-240
dc.descriptionShinchi, M.J., Soma, K., Nakabayashi, N., The effect of phosphoric acid concentration on resin tag length and bond strength of a photo-cured resin to acid-etched enamel (2000) Dent Mater, 16, pp. 324-329
dc.descriptionYoshida, Y., Nagakane, K., Fukuda, R., Nakayama, Y., Okazaki, M., Shintani, H., Comparative study on adhesive performance of functional monomers (2004) J Dent Res, 83, pp. 454-458
dc.descriptionTakahashi, A., Sato, Y., Uno, S., Pereira, P.N.R., Sano, H., Effects of mechanical properties of adhesive resins on bond strength to dentin (2002) Dent Mater, 18, pp. 263-268
dc.descriptionSalz, U., Zimmermann, J., Zeuner, F., Moszner, N., Hydrolytic stability of self-etching adhesive systems (2005) J Adhes Dent, 7, pp. 107-116
dc.descriptionCehreli, Z.C., Altay, N., Effects of a nonrinse conditioner and 17% ethylenediaminetetraacetic acid on the etch pattern of intact human permanent enamel (2000) Angle Orthod, 70, pp. 22-27
dc.descriptionCamps, J., Pashley, D.H., Buffering action of human dentin in vitro (2000) J Adhes Dent, 2, pp. 39-50
dc.descriptionRipa, L.W., Gwinnett, A.J., Buonocore, M.G., The "prismless" outer layer of deciduous and permanent enamel (1966) Arch Oral Biol, 11, pp. 41-48
dc.languageen
dc.publisher
dc.relationBrazilian Dental Journal
dc.rightsaberto
dc.sourceScopus
dc.titleMicrotensile Bond Strength Test And Failure Analysis To Assess Bonding Characteristics Of Different Adhesion Approaches To Ground Versus Unground Enamel
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución