dc.creatorAlexandrino J.C.
dc.creatorLeite H.J.D.
dc.creatorKalid R.A.
dc.creatorHermini A.H.
dc.creatorLepikson H.A.
dc.date2011
dc.date2015-06-30T20:17:52Z
dc.date2015-11-26T14:47:53Z
dc.date2015-06-30T20:17:52Z
dc.date2015-11-26T14:47:53Z
dc.date.accessioned2018-03-28T21:58:32Z
dc.date.available2018-03-28T21:58:32Z
dc.identifier
dc.identifierRevista Brasileira De Engenharia Biomedica. , v. 27, n. 3, p. 194 - 197, 2011.
dc.identifier15173151
dc.identifier10.4322/rbeb.2011.016
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-83655181131&partnerID=40&md5=26482cbf9bae8121ee67f3672cf4151e
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/107481
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/107481
dc.identifier2-s2.0-83655181131
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1253448
dc.descriptionAlthough designed to benefit premature newborns (NB) by creating an artificial environment close to the uterine conditions, the use of neonatal incubators may expose the NB to several sources of risk. Periodic inspections for verification of minimum requirements of performance and safety can identify these and their degrees of impact, helping to minimize them. In order to automate the metrological evaluation essays in neonatal incubators, we present the development of an analyzer with the capacity to perform all measurements of the variables defined in the standard NBR IEC 60601-2-19 and communicate them to a computer allowing the transmission of measurement data and reception of commands for remote adjustment. The development of this system creates a nationalized alternative with cheaper and more suitable features for the metrological tests required. As a result, we obtained a micro-controlled portable and useful modular prototype, which measures temperature, relative humidity, oxygen concentration, acoustic noise and air speed. The calibration results show that the maximum relative error and measurement uncertainty for the subsystems of temperature, relative humidity, acoustic noise and O 2 concentration were respectively (-0.42; 0.05 °C), (±0.72; 0.24%) RH, (-5.17; 0.68 dB) and (1.28; 2.2%). These results indicate that the analyzer presents a metrological quality compatible with the regulatory requirements established.
dc.description27
dc.description3
dc.description194
dc.description197
dc.descriptionAshton, N., Ward, B., Serpell, G., Role of oxygen in the genesis of retrolental fibroplasia: A preliminary report (1953) British Journal of Ophthalmology, 37 (9), pp. 513-520. , http://dx.doi.org/10.1136/bjo.37.9.513, PMid:13081949. PMCid:1324188
dc.description(2000) NBR IEC 60601-2-19: Equipamento Eletromédico, Parte 2-19: Prescrições Particulares Para Segurança De Incubadoras Para Recém-nascidos (RN), , Associação Brasileira de Normas Técnicas - ABNT, Rio de Janeiro: Associação Brasileira de Normas Técnicas
dc.descriptionBercini, L.O., Mortalidade neonatal de residentes em localidade urbana da região sul do Brasil (1994) Revista De Saúde Pública, 28 (1), pp. 38-45. , http://dx.doi.org/10.1590/S0034-89101994000100005
dc.descriptionCarvalho, A.P., Pereira, L.F., Noise In Infant Incubators and In Neonatal Intensive Care Units, , http://paginas.fe.up.pt/~carvalho/in98.pdf, In: International Conference on Noise Control Engineering: Proceedings of the 1998 International Conference on Noise Control Engineering [Internet]
dc.description1998 November 16-18
dc.descriptionChristchurch, New Zealand. [cited 2010 mar 22]
dc.descriptionFalk, S.A., Farmer, J.C., Incubator noise and possible deafness (1973) Archives of Otolaryngology - Head & Neck Surgery, 97 (5), pp. 385-387
dc.descriptionHowe, W.G., Two-sided tolerance limits for normal populations - Some improvements (1969) Journal of the American Statistical Association, 64 (326), pp. 610-620. , http://dx.doi.org/10.2307/2283644
dc.description(2002) IEC 61672-1: Electroacoustics - Sound Level Meters - Part 1: Specifications, p. 85. , International Electrotechnical Commission - IEC, Geneva: International Electrotechnical Commission
dc.description(1997) ISO 7767: Oxygen Monitors For Monitoring Patient Breathing Mixtures - Safety Requirements, , International Organization for Standardization - ISO, Geneva: International Organization for Standardization
dc.description(2004) ISO 21647: Medical Electrical Equipment - Particular Requirements For the Basic Safety and Essential Performance of Respiratory Gas Monitors, , International Organization for Standardization - ISO, Geneva: International Organization for Standardization
dc.descriptionKim, Y.H., Kwon, C.H., Yoo, S.C., Experimental and numerical studies on convective heat transfer in a neonatal incubator (2002) Medical & Biological Engineering & Computing, 40 (1), pp. 114-121. , http://dx.doi.org/10.1007/BF02347704, PMid:11954698
dc.descriptionMaluf, N., Williams, K., (2004) An Introduction to Microelectromechanical Systems Engineering, p. 304. , 2th ed. Norwood: Artech House Publishers
dc.descriptionRego, M.A.S., Anchieta, L.M., (2005) Assistência Hospitalar Ao Neonato, , http://www.saude.mg.gov.br/publicacoes/linha-guia/protocolos/assistencia_ hospitalar_neonato.pdf, Belo Horizonte: Secretaria de Estado de Saúde de Minas Gerais, Internet, cited 2010 mar 25
dc.descriptionRodrigues, R.G., Oliveira, I.C.S., Os primórdios da assistência aos recém-nascidos no exterior e no Brasil: Perspectivas para o saber de enfermagem na neonatologia (1870-1903) (2004) Revista Eletrônica De Enfermagem, , http://www.revistas.ufg.br/index.php/fen/article/view/809/924, Internet, cited 2011 nov 10
dc.descriptionSteinhart, J.S., Hart, S.R., Calibration curves for thermistors (1968) Deep Sea Research and Oceanographic Abstracts, 15 (4), pp. 497-503. , http://dx.doi.org/10.1016/0011-7471(68)90057-0
dc.languageen
dc.languagept
dc.publisher
dc.relationRevista Brasileira de Engenharia Biomedica
dc.rightsaberto
dc.sourceScopus
dc.titleDevelopment Of A Neonatal Incubator Analyzer [desenvolvimento De Um Analisador De Incubadoras Neonatais]
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución