dc.creatorCarvalhal C.I.O.
dc.creatorde Mello J.A.N.
dc.creatorSobrinho L.C.
dc.creatorCorrer A.B.
dc.creatorSinhoreti M.A.C.
dc.date2011
dc.date2015-06-30T20:18:22Z
dc.date2015-11-26T14:47:51Z
dc.date2015-06-30T20:18:22Z
dc.date2015-11-26T14:47:51Z
dc.date.accessioned2018-03-28T21:58:29Z
dc.date.available2018-03-28T21:58:29Z
dc.identifier
dc.identifierJournal Of Contemporary Dental Practice. , v. 12, n. 4, p. 252 - 258, 2011.
dc.identifier15263711
dc.identifier10.5005/jp-journals-10024-1043
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-84856288832&partnerID=40&md5=85b735ba4688cc37bbd114ba6a1fe324
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/107513
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/107513
dc.identifier2-s2.0-84856288832
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1253437
dc.descriptionAim: The aim of this study was to evaluate the influence of immersion period in two disinfectant solutions on dimensional change of four elastomeric impression materials. Materials and methods: Four representative materials of each class of elastomers: Xantopren (polydimethylsiloxane-PDS), Express (polyvinyl siloxane-PVS); Permlastic (polysulfide-PS) and Soft Impregum (polyether-EP) were mixed according to manufacturers' instructions and then inserted into a metal matrix prepared according to the specification of ISO 4823. The molds were removed from the matrix after 7 minutes and immersed in disinfectant solutions (sodium hypochlorite 0.5 and 2% glutaraldehyde) for 5, 10, 20, 30 and 60 minutes (n = 7), except the control group, which was not immersed. Once removed from solutions, the test samples were washed in water for 15 seconds, dried and measured three times, using a comparative optical microscope, with accuracy of 0.0005 mm. The analysis of variance with three criteria and Tukey's test with significance level of 5% showed that differences in linear dimensions of the materials analyzed were not statistically significant (p > 0.05) after soaking in sodium hypochlorite 0.5 and 2% glutaraldehyde, for the tested periods of time. Clinical significance: Combinations of molding material and disinfecting solution can be used in the dental clinic for infection control, without changing the dimensional molds, for immersion periods not longer than 20 minutes.
dc.description12
dc.description4
dc.description252
dc.description258
dc.descriptionGuandallini, S.L., Bio Segurança (1996) J Bras Orto Ortop Facial, 1, pp. 5-8
dc.descriptionKimondollo, P.M., Guidelines for developing a dental laboratory infection-control protocol (1992) Int J Prosthodont, 5, pp. 452-456
dc.descriptionAdabo, G.L., Zanarotti, E., Fonseca, R.G., Cruz, C.A., Effect of disinfectant agents on dimensional stability of elastomeric impression materials (1999) J Prosthet Dent, 81, pp. 621-624
dc.descriptionMinagi, S., Kohada, A., Akagawa, Y., Tsuru, H., Prevention of acquired immunodeficiency syndrome and hepatitis B (Part III): Disinfection of hydrophilic silicone rubber impression materials (1990) J Prosthet Dent, 64, pp. 463-465
dc.descriptionMinagi, S., Yano, N., Yoshida, K., Tsuru, H., Prevention of acquired immunodeficiency syndrome and hepatitis B (Part II): Disinfection method for hydrophilic impression materials (1987) J Prosthet Dent, 58, pp. 462-465
dc.descriptionAlves-Rezende, M.C.R., Lorenzato, F., Efeito de desinfecção por aerossóis sobre a capacidade de umedecimento de moldes de poliéter por gesso tipo IV (1999) Rev Odont USP, 13, pp. 363-367
dc.descriptionCouncil on prosthetic services and dental laboratory relations (1985) J Am Dent Assoc, 110, pp. 969-972. , Guidelines for infection control in the dental office and the commercial dental laboratory. Council on dental therapeutics
dc.descriptionMuller-Bolla, M., Lupi-Pegurier, L., Velly, A.M., Bolla, M., A survey of disinfection of irreversible hydrocolloid and silicone impressions in European Union dental schools: Epidemiologic study (2004) Int J Prosthodont, 17, pp. 165-171
dc.descriptionOwen, C.P., Goolam, R., Disinfection of impression materials to prevent viral cross contamination: A review and a protocol (1993) Int J Prosthodont, 6, pp. 480-494
dc.descriptionCraig, R.G., Urquiola, N.J., Liu, C.C., Comparison of commercial elastomeric impression materials (1990) Oper Dent, 15, pp. 94-104
dc.descriptionAnusavice, K.J., (2005) Phillips materiais dentários, , (11th ed). Rio de Janeiro: Elsevier
dc.descriptionChen, S.Y., Liang, W.M., Chen, F.N., Factors affecting the accuracy of elastometric impression materials (2004) J Dent, 32, pp. 603-609
dc.descriptionPetrie, C.S., Walker, M.P., O'Mahony, A.M., Spencer, P., Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry, moist, and wet conditions (2003) J Prosthet Dent, 90, pp. 365-372
dc.descriptionRubel, B.S., Impression materials: A comparative review of impression materials most commonly used in restorative dentistry (2007) Dent Clin North Am, 51, pp. 629-642. , vi
dc.descriptionMandikos, M.N., Polyvinyl siloxane impression materials: An update on clinical use (1998) Aust Dent J, 43, pp. 428-434
dc.descriptionCraig, R., Powers, J.M., (2002) Restorative Dental Materials, , St Louis: Mosby, Inc
dc.descriptionThouati, A., Deveaux, E., Iost, A., Behin, P., Dimensional stability of seven elastomeric impression materials immersed in disinfectants (1996) J Prosthet Dent, 76, pp. 8-14
dc.descriptionLepe, X., Johnson, G.H., Accuracy of polyether and addition silicone after long-term immersion disinfection (1997) J Prosthet Dent, 78, pp. 245-249
dc.descriptionChong, Y.H., Soh, G., Setchell, D.J., Wickens, J.L., Relationship between contact angles of die stone on elastomeric impression materials and voids in stone casts (1990) Dent Mater, 6, pp. 162-166
dc.descriptionKanehira, M., Finger, W.J., Endo, T., Volatilization of components from and water absorption of polyether impressions (2006) J Dent, 34, pp. 134-138
dc.descriptionMcCabe, J.F., Carrick, T.E., Recording surface detail on moist surfaces with elastomeric impression materials (2006) Eur J Prosthodont Restor Dent, 14, pp. 42-46
dc.descriptionMelilli, D., Rallo, A., Cassaro, A., Pizzo, G., The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials (2008) J Oral Sci, 50, pp. 441-446
dc.descriptionPodshadley, A.G., Dilts, W.E., Neiman, R., Sawyer, H.F., Accuracy of a mercaptan rubber impression technique using a stock tray (1971) J Am Dent Assoc, 83, pp. 1303-1308
dc.descriptionWalker, M.P., Rondeau, M., Petrie, C., Surface quality and longterm dimensional stability of current elastomeric impression materials after disinfection (2007) J Prosthodont, 16, pp. 343-351
dc.descriptionMemarian, M., Fazeli, M.R., Jamalifar, H., Azimnejad, A., Disinfection efficiency of irreversible hydrocolloid impressions using different concentrations of sodium hypochlorite: A pilot study (2007) J Contemp Dent Pract, 8, pp. 27-34
dc.descriptionTaylor, R.L., Wright, P.S., Maryan, C., Disinfection procedures: Their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts (2002) Dent Mater, 18, pp. 103-110
dc.descriptionLangenwalter, E.M., Aquilino, S.A., Turner, K.A., The dimensional stability of elastomeric impression materials following disinfection (1990) J Prosthet Dent, 63, pp. 270-276
dc.descriptionTullner, J.B., Commette, J.A., Moon, P.C., Linear dimensional changes in dental impressions after immersion in disinfectant solutions (1988) J Prosthet Dent, 60, pp. 725-728
dc.descriptionYilmaz, H., Aydin, C., Gul, B., Effect of disinfection on the dimensional stability of polyether impression materials (2007) J Prosthodont, 16, pp. 473-479
dc.descriptionJohnson, G.H., Chellis, K.D., Gordon, G.E., Lepe, X., Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion (1998) J Prosthet Dent, 79, pp. 446-453
dc.languageen
dc.publisher
dc.relationJournal of Contemporary Dental Practice
dc.rightsfechado
dc.sourceScopus
dc.titleDimensional Change Of Elastomeric Materials After Immersion In Disinfectant Solutions For Different Times
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución