dc.creator | Carvalhal C.I.O. | |
dc.creator | de Mello J.A.N. | |
dc.creator | Sobrinho L.C. | |
dc.creator | Correr A.B. | |
dc.creator | Sinhoreti M.A.C. | |
dc.date | 2011 | |
dc.date | 2015-06-30T20:18:22Z | |
dc.date | 2015-11-26T14:47:51Z | |
dc.date | 2015-06-30T20:18:22Z | |
dc.date | 2015-11-26T14:47:51Z | |
dc.date.accessioned | 2018-03-28T21:58:29Z | |
dc.date.available | 2018-03-28T21:58:29Z | |
dc.identifier | | |
dc.identifier | Journal Of Contemporary Dental Practice. , v. 12, n. 4, p. 252 - 258, 2011. | |
dc.identifier | 15263711 | |
dc.identifier | 10.5005/jp-journals-10024-1043 | |
dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-84856288832&partnerID=40&md5=85b735ba4688cc37bbd114ba6a1fe324 | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/107513 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/107513 | |
dc.identifier | 2-s2.0-84856288832 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1253437 | |
dc.description | Aim: The aim of this study was to evaluate the influence of immersion period in two disinfectant solutions on dimensional change of four elastomeric impression materials. Materials and methods: Four representative materials of each class of elastomers: Xantopren (polydimethylsiloxane-PDS), Express (polyvinyl siloxane-PVS); Permlastic (polysulfide-PS) and Soft Impregum (polyether-EP) were mixed according to manufacturers' instructions and then inserted into a metal matrix prepared according to the specification of ISO 4823. The molds were removed from the matrix after 7 minutes and immersed in disinfectant solutions (sodium hypochlorite 0.5 and 2% glutaraldehyde) for 5, 10, 20, 30 and 60 minutes (n = 7), except the control group, which was not immersed. Once removed from solutions, the test samples were washed in water for 15 seconds, dried and measured three times, using a comparative optical microscope, with accuracy of 0.0005 mm. The analysis of variance with three criteria and Tukey's test with significance level of 5% showed that differences in linear dimensions of the materials analyzed were not statistically significant (p > 0.05) after soaking in sodium hypochlorite 0.5 and 2% glutaraldehyde, for the tested periods of time. Clinical significance: Combinations of molding material and disinfecting solution can be used in the dental clinic for infection control, without changing the dimensional molds, for immersion periods not longer than 20 minutes. | |
dc.description | 12 | |
dc.description | 4 | |
dc.description | 252 | |
dc.description | 258 | |
dc.description | Guandallini, S.L., Bio Segurança (1996) J Bras Orto Ortop Facial, 1, pp. 5-8 | |
dc.description | Kimondollo, P.M., Guidelines for developing a dental laboratory infection-control protocol (1992) Int J Prosthodont, 5, pp. 452-456 | |
dc.description | Adabo, G.L., Zanarotti, E., Fonseca, R.G., Cruz, C.A., Effect of disinfectant agents on dimensional stability of elastomeric impression materials (1999) J Prosthet Dent, 81, pp. 621-624 | |
dc.description | Minagi, S., Kohada, A., Akagawa, Y., Tsuru, H., Prevention of acquired immunodeficiency syndrome and hepatitis B (Part III): Disinfection of hydrophilic silicone rubber impression materials (1990) J Prosthet Dent, 64, pp. 463-465 | |
dc.description | Minagi, S., Yano, N., Yoshida, K., Tsuru, H., Prevention of acquired immunodeficiency syndrome and hepatitis B (Part II): Disinfection method for hydrophilic impression materials (1987) J Prosthet Dent, 58, pp. 462-465 | |
dc.description | Alves-Rezende, M.C.R., Lorenzato, F., Efeito de desinfecção por aerossóis sobre a capacidade de umedecimento de moldes de poliéter por gesso tipo IV (1999) Rev Odont USP, 13, pp. 363-367 | |
dc.description | Council on prosthetic services and dental laboratory relations (1985) J Am Dent Assoc, 110, pp. 969-972. , Guidelines for infection control in the dental office and the commercial dental laboratory. Council on dental therapeutics | |
dc.description | Muller-Bolla, M., Lupi-Pegurier, L., Velly, A.M., Bolla, M., A survey of disinfection of irreversible hydrocolloid and silicone impressions in European Union dental schools: Epidemiologic study (2004) Int J Prosthodont, 17, pp. 165-171 | |
dc.description | Owen, C.P., Goolam, R., Disinfection of impression materials to prevent viral cross contamination: A review and a protocol (1993) Int J Prosthodont, 6, pp. 480-494 | |
dc.description | Craig, R.G., Urquiola, N.J., Liu, C.C., Comparison of commercial elastomeric impression materials (1990) Oper Dent, 15, pp. 94-104 | |
dc.description | Anusavice, K.J., (2005) Phillips materiais dentários, , (11th ed). Rio de Janeiro: Elsevier | |
dc.description | Chen, S.Y., Liang, W.M., Chen, F.N., Factors affecting the accuracy of elastometric impression materials (2004) J Dent, 32, pp. 603-609 | |
dc.description | Petrie, C.S., Walker, M.P., O'Mahony, A.M., Spencer, P., Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry, moist, and wet conditions (2003) J Prosthet Dent, 90, pp. 365-372 | |
dc.description | Rubel, B.S., Impression materials: A comparative review of impression materials most commonly used in restorative dentistry (2007) Dent Clin North Am, 51, pp. 629-642. , vi | |
dc.description | Mandikos, M.N., Polyvinyl siloxane impression materials: An update on clinical use (1998) Aust Dent J, 43, pp. 428-434 | |
dc.description | Craig, R., Powers, J.M., (2002) Restorative Dental Materials, , St Louis: Mosby, Inc | |
dc.description | Thouati, A., Deveaux, E., Iost, A., Behin, P., Dimensional stability of seven elastomeric impression materials immersed in disinfectants (1996) J Prosthet Dent, 76, pp. 8-14 | |
dc.description | Lepe, X., Johnson, G.H., Accuracy of polyether and addition silicone after long-term immersion disinfection (1997) J Prosthet Dent, 78, pp. 245-249 | |
dc.description | Chong, Y.H., Soh, G., Setchell, D.J., Wickens, J.L., Relationship between contact angles of die stone on elastomeric impression materials and voids in stone casts (1990) Dent Mater, 6, pp. 162-166 | |
dc.description | Kanehira, M., Finger, W.J., Endo, T., Volatilization of components from and water absorption of polyether impressions (2006) J Dent, 34, pp. 134-138 | |
dc.description | McCabe, J.F., Carrick, T.E., Recording surface detail on moist surfaces with elastomeric impression materials (2006) Eur J Prosthodont Restor Dent, 14, pp. 42-46 | |
dc.description | Melilli, D., Rallo, A., Cassaro, A., Pizzo, G., The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials (2008) J Oral Sci, 50, pp. 441-446 | |
dc.description | Podshadley, A.G., Dilts, W.E., Neiman, R., Sawyer, H.F., Accuracy of a mercaptan rubber impression technique using a stock tray (1971) J Am Dent Assoc, 83, pp. 1303-1308 | |
dc.description | Walker, M.P., Rondeau, M., Petrie, C., Surface quality and longterm dimensional stability of current elastomeric impression materials after disinfection (2007) J Prosthodont, 16, pp. 343-351 | |
dc.description | Memarian, M., Fazeli, M.R., Jamalifar, H., Azimnejad, A., Disinfection efficiency of irreversible hydrocolloid impressions using different concentrations of sodium hypochlorite: A pilot study (2007) J Contemp Dent Pract, 8, pp. 27-34 | |
dc.description | Taylor, R.L., Wright, P.S., Maryan, C., Disinfection procedures: Their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts (2002) Dent Mater, 18, pp. 103-110 | |
dc.description | Langenwalter, E.M., Aquilino, S.A., Turner, K.A., The dimensional stability of elastomeric impression materials following disinfection (1990) J Prosthet Dent, 63, pp. 270-276 | |
dc.description | Tullner, J.B., Commette, J.A., Moon, P.C., Linear dimensional changes in dental impressions after immersion in disinfectant solutions (1988) J Prosthet Dent, 60, pp. 725-728 | |
dc.description | Yilmaz, H., Aydin, C., Gul, B., Effect of disinfection on the dimensional stability of polyether impression materials (2007) J Prosthodont, 16, pp. 473-479 | |
dc.description | Johnson, G.H., Chellis, K.D., Gordon, G.E., Lepe, X., Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion (1998) J Prosthet Dent, 79, pp. 446-453 | |
dc.language | en | |
dc.publisher | | |
dc.relation | Journal of Contemporary Dental Practice | |
dc.rights | fechado | |
dc.source | Scopus | |
dc.title | Dimensional Change Of Elastomeric Materials After Immersion In Disinfectant Solutions For Different Times | |
dc.type | Artículos de revistas | |