dc.creatorDelben J.A.
dc.creatorBarao V.A.R.
dc.creatorDos Santos P.H.
dc.creatorAssuncao W.G.
dc.date2014
dc.date2015-06-25T17:56:47Z
dc.date2015-11-26T14:46:59Z
dc.date2015-06-25T17:56:47Z
dc.date2015-11-26T14:46:59Z
dc.date.accessioned2018-03-28T21:57:06Z
dc.date.available2018-03-28T21:57:06Z
dc.identifier
dc.identifierJournal Of Prosthodontics. , v. 23, n. 2, p. 134 - 139, 2014.
dc.identifier1059941X
dc.identifier10.1111/jopr.12065
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-84894090600&partnerID=40&md5=ae319f58714a15b871a7b7a6d556d16e
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/87115
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/87115
dc.identifier2-s2.0-84894090600
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1253083
dc.descriptionPurpose: The effect of veneering materials on screw joint stability remains inconclusive. Thus, this study evaluated the preload maintenance of abutment screws of single crowns fabricated with different abutments and veneering materials. Materials and Methods: Sixty crowns were divided into five groups (n = 12): UCLA abutment in gold alloy with ceramic (group GC) and resin (group GR) veneering, UCLA abutment in titanium with ceramic (group TiC) and resin (group TiR) veneering, and zirconia abutment with ceramic veneering (group ZiC). Abutment screws made of gold were used with a 35 Ncm insertion torque. Detorque measurements were obtained initially and after mechanical cycling. Data were analyzed by ANOVA and Fisher's exact test at a significance level of 5%. Results: For the initial detorque means (in Ncm), group TiC (21.4 ± 1.78) exhibited statistically lower torque maintenance than groups GC (23.9 ± 0.91), GR (24.1 ± 1.34), and TiR (23.2 ± 1.33) (p < 0.05, Fisher's exact test). Group ZiC (21.9 ± 2.68) exhibited significantly lower torque maintenance than groups GC, GR, and TiR (p < 0.05, Fisher's exact test). After mechanical cycling, there was a statistically significant difference between groups TiC (22.1 ± 1.86) and GR (23.8 ± 1.56); between groups ZiC (21.7 ± 2.02) and GR; and also between groups ZiC and TiR (23.6 ± 1.30) (p < 0.05, Fisher's exact test). Conclusions: Detorque reduction occurred regardless of abutment type and veneering material. More irregular surfaces in the hexagon area of the castable abutments were observed. The superiority of any veneering material concerning preload maintenance was not established. © 2013 by the American College of Prosthodontists.
dc.description23
dc.description2
dc.description134
dc.description139
dc.descriptionBranemark, P.I., Zarb, G., Albrektsson, T., (1987) Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry. Special Edition for Nobelpharma, , Chicago, Quintessence
dc.descriptionJorneus, L., Jemt, T., Carlsson, L., Loads and designs of screw joints for single crowns supported by osseointegrated implants (1992) Int J Oral Maxillofac Implants, 7, pp. 353-359
dc.descriptionBinon, P.P., The effect of implant/abutment hexagonal misfit on screw joint stability (1996) Int J Prosthodont, 9, pp. 149-160
dc.descriptionWeiss, E.I., Kozak, D., Gross, M.D., Effect of repeated closures on opening torque values in seven abutment-implant systems (2000) J Prosthet Dent, 84, pp. 194-199
dc.descriptionDelben, J.A., Gomes, E.A., Barao, V.A., Evaluation of the effect of retightening and mechanical cycling on preload maintenance of retention screws (2011) Int J Oral Maxillofac Implants, 26, pp. 251-256
dc.descriptionAssuncao, W.G., Barao, V.A., Delben, J.A., Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling (2011) J Prosthodont Res, 55, pp. 12-18
dc.descriptionAssuncao, W.G., Delben, J.A., Tabata, L.F., Preload evaluation of different screws in external hexagon joint (2012) Implant Dent, 21, pp. 46-50
dc.descriptionBurguete, R.L., Johns, R.B., King, T., Tightening characteristics for screwed joints in osseointegrated dental implants (1994) J Prosthet Dent, 71, pp. 592-599
dc.descriptionSaboury, A., Neshandar Asli, H., Vaziri, S., The effect of repeated torque in small diameter implants with machined and premachined abutments (2012) Clin Implant Dent Relat Res, 14 (SUPPL. 1), pp. e224-e230
dc.descriptionCibirka, R.M., Nelson, S.K., Lang, B.R., Examination of the implant-abutment interface after fatigue testing (2001) J Prosthet Dent, 85, pp. 268-275
dc.descriptionKano, S.C., Binon, P., Bonfante, G., Effect of casting procedures on screw loosening in UCLA-type abutments (2006) J Prosthodont, 15, pp. 77-81
dc.descriptionBickford, J.H., (1995) An Introduction to the Designs and Behavior of Bolted Joints, , New York, Marcel Dekker
dc.descriptionCarr, A.B., Brunski, J.B., Hurley, E., Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold" and plastic cylinders (1996) Int J Oral Maxillofac Implants, 11, pp. 589-598
dc.descriptionByrne, D., Jacobs, S., O'Connell, B., Preloads generated with repeated tightening in three types of screws used in dental implant assemblies (2006) J Prosthodont, 15, pp. 164-171
dc.descriptionSkalak, R., Biomechanical considerations in osseointegrated prostheses (1983) J Prosthet Dent, 49, pp. 843-848
dc.descriptionCibirka, R.M., Razzoog, M.E., Lang, B.R., Determining the force absorption quotient for restorative materials used in implant occlusal surfaces (1992) J Prosthet Dent, 67, pp. 361-364
dc.descriptionStegaroiu, R., Kusakari, H., Nishiyama, S., Influence of prosthesis material on stress distribution in bone and implant: a 3-dimensional finite element analysis (1998) Int J Oral Maxillofac Implants, 13, pp. 781-790
dc.descriptionInan, O., Kesim, B., Evaluation of the effects of restorative materials used for occlusal surfaces of implant-supported prostheses on force distribution (1999) Implant Dent, 8, pp. 311-316
dc.descriptionSoumeire, J., Dejou, J., Shock absorbability of various restorative materials used on implants (1999) J Oral Rehabil, 26, pp. 394-401
dc.descriptionVigolo, P., Majzoub, Z., Cordioli, G., Measurement of the dimensions and abutment rotational freedom of gold-machined 3i UCLA-type abutments in the as-received condition, after casting with a noble metal alloy and porcelain firing (2000) J Prosthet Dent, 84, pp. 548-553
dc.descriptionCiftci, Y., Canay, S., Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials (2001) Int J Prosthodont, 14, pp. 406-411
dc.descriptionWang, T.M., Leu, L.J., Wang, J., Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis (2002) Int J Oral Maxillofac Implants, 17, pp. 231-237
dc.descriptionFonseca, J.C., Henriques, G.E., Sobrinho, L.C., Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings (2003) Dent Mater, 19, pp. 686-691
dc.descriptionKoke, U., Wolf, A., Lenz, P., In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures (2004) J Oral Rehabil, 31, pp. 477-482
dc.descriptionKarl, M., Rosch, S., Graef, F., Static implant loading caused by as-cast metal and ceramic-veneered superstructures (2005) J Prosthet Dent, 93, pp. 324-330
dc.descriptionOrtorp, A., Jemt, T., Wennerberg, A., Screw preloads and measurements of surface roughness in screw joints: an in vitro study on implant frameworks (2005) Clin Implant Dent Relat Res, 7, pp. 141-149
dc.descriptionHecker, D.M., Eckert, S.E., Cyclic loading of implant-supported prostheses: changes in component fit over time (2003) J Prosthet Dent, 89, pp. 346-351
dc.descriptionSartori, I.A., Ribeiro, R.F., Francischone, C.E., In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion (2004) J Prosthet Dent, 92, pp. 132-138
dc.descriptionKucey, B.K., Fraser, D.C., The Procera abutment-the fifth generation abutment for dental implants (2000) J Can Dent Assoc, 66, pp. 445-449
dc.descriptionGarine, W.N., Funkenbusch, P.D., Ercoli, C., Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments (2007) Int J Oral Maxillofac Implants, 22, pp. 928-938
dc.descriptionVult von Steyern, P., Ebbesson, S., Holmgren, J., Fracture strength of two oxide ceramic crown systems after cyclic pre-loading and thermocycling (2006) J Oral Rehabil, 33, pp. 682-689
dc.descriptionShirakura, A., Lee, H., Geminiani, A., The influence of veneering porcelain thickness of all-ceramic and metal ceramic crowns on failure resistance after cyclic loading (2009) J Prosthet Dent, 101, pp. 119-127
dc.descriptionKarl, M., Graef, F., Taylor, T.D., In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorations (2007) J Prosthet Dent, 97, pp. 137-140
dc.descriptionAssunção, W.G., Delben, J.A., Tabata, L.F., Effect of vertical misfit on screw joint stability of implant-supported crowns (2011) J Mater Eng Perform, 20, pp. 947-951
dc.descriptionShigley, J.E., Mischke, C.R., (2001) Mechanical Engineering Design, , New York, McGraw Hill
dc.languageen
dc.publisher
dc.relationJournal of Prosthodontics
dc.rightsfechado
dc.sourceScopus
dc.titleInfluence Of Abutment Type And Esthetic Veneering On Preload Maintenance Of Abutment Screw Of Implant-supported Crowns
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución