| dc.creator | Delben J.A. | |
| dc.creator | Barao V.A.R. | |
| dc.creator | Dos Santos P.H. | |
| dc.creator | Assuncao W.G. | |
| dc.date | 2014 | |
| dc.date | 2015-06-25T17:56:47Z | |
| dc.date | 2015-11-26T14:46:59Z | |
| dc.date | 2015-06-25T17:56:47Z | |
| dc.date | 2015-11-26T14:46:59Z | |
| dc.date.accessioned | 2018-03-28T21:57:06Z | |
| dc.date.available | 2018-03-28T21:57:06Z | |
| dc.identifier | | |
| dc.identifier | Journal Of Prosthodontics. , v. 23, n. 2, p. 134 - 139, 2014. | |
| dc.identifier | 1059941X | |
| dc.identifier | 10.1111/jopr.12065 | |
| dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-84894090600&partnerID=40&md5=ae319f58714a15b871a7b7a6d556d16e | |
| dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/87115 | |
| dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/87115 | |
| dc.identifier | 2-s2.0-84894090600 | |
| dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1253083 | |
| dc.description | Purpose: The effect of veneering materials on screw joint stability remains inconclusive. Thus, this study evaluated the preload maintenance of abutment screws of single crowns fabricated with different abutments and veneering materials. Materials and Methods: Sixty crowns were divided into five groups (n = 12): UCLA abutment in gold alloy with ceramic (group GC) and resin (group GR) veneering, UCLA abutment in titanium with ceramic (group TiC) and resin (group TiR) veneering, and zirconia abutment with ceramic veneering (group ZiC). Abutment screws made of gold were used with a 35 Ncm insertion torque. Detorque measurements were obtained initially and after mechanical cycling. Data were analyzed by ANOVA and Fisher's exact test at a significance level of 5%. Results: For the initial detorque means (in Ncm), group TiC (21.4 ± 1.78) exhibited statistically lower torque maintenance than groups GC (23.9 ± 0.91), GR (24.1 ± 1.34), and TiR (23.2 ± 1.33) (p < 0.05, Fisher's exact test). Group ZiC (21.9 ± 2.68) exhibited significantly lower torque maintenance than groups GC, GR, and TiR (p < 0.05, Fisher's exact test). After mechanical cycling, there was a statistically significant difference between groups TiC (22.1 ± 1.86) and GR (23.8 ± 1.56); between groups ZiC (21.7 ± 2.02) and GR; and also between groups ZiC and TiR (23.6 ± 1.30) (p < 0.05, Fisher's exact test). Conclusions: Detorque reduction occurred regardless of abutment type and veneering material. More irregular surfaces in the hexagon area of the castable abutments were observed. The superiority of any veneering material concerning preload maintenance was not established. © 2013 by the American College of Prosthodontists. | |
| dc.description | 23 | |
| dc.description | 2 | |
| dc.description | 134 | |
| dc.description | 139 | |
| dc.description | Branemark, P.I., Zarb, G., Albrektsson, T., (1987) Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry. Special Edition for Nobelpharma, , Chicago, Quintessence | |
| dc.description | Jorneus, L., Jemt, T., Carlsson, L., Loads and designs of screw joints for single crowns supported by osseointegrated implants (1992) Int J Oral Maxillofac Implants, 7, pp. 353-359 | |
| dc.description | Binon, P.P., The effect of implant/abutment hexagonal misfit on screw joint stability (1996) Int J Prosthodont, 9, pp. 149-160 | |
| dc.description | Weiss, E.I., Kozak, D., Gross, M.D., Effect of repeated closures on opening torque values in seven abutment-implant systems (2000) J Prosthet Dent, 84, pp. 194-199 | |
| dc.description | Delben, J.A., Gomes, E.A., Barao, V.A., Evaluation of the effect of retightening and mechanical cycling on preload maintenance of retention screws (2011) Int J Oral Maxillofac Implants, 26, pp. 251-256 | |
| dc.description | Assuncao, W.G., Barao, V.A., Delben, J.A., Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling (2011) J Prosthodont Res, 55, pp. 12-18 | |
| dc.description | Assuncao, W.G., Delben, J.A., Tabata, L.F., Preload evaluation of different screws in external hexagon joint (2012) Implant Dent, 21, pp. 46-50 | |
| dc.description | Burguete, R.L., Johns, R.B., King, T., Tightening characteristics for screwed joints in osseointegrated dental implants (1994) J Prosthet Dent, 71, pp. 592-599 | |
| dc.description | Saboury, A., Neshandar Asli, H., Vaziri, S., The effect of repeated torque in small diameter implants with machined and premachined abutments (2012) Clin Implant Dent Relat Res, 14 (SUPPL. 1), pp. e224-e230 | |
| dc.description | Cibirka, R.M., Nelson, S.K., Lang, B.R., Examination of the implant-abutment interface after fatigue testing (2001) J Prosthet Dent, 85, pp. 268-275 | |
| dc.description | Kano, S.C., Binon, P., Bonfante, G., Effect of casting procedures on screw loosening in UCLA-type abutments (2006) J Prosthodont, 15, pp. 77-81 | |
| dc.description | Bickford, J.H., (1995) An Introduction to the Designs and Behavior of Bolted Joints, , New York, Marcel Dekker | |
| dc.description | Carr, A.B., Brunski, J.B., Hurley, E., Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold" and plastic cylinders (1996) Int J Oral Maxillofac Implants, 11, pp. 589-598 | |
| dc.description | Byrne, D., Jacobs, S., O'Connell, B., Preloads generated with repeated tightening in three types of screws used in dental implant assemblies (2006) J Prosthodont, 15, pp. 164-171 | |
| dc.description | Skalak, R., Biomechanical considerations in osseointegrated prostheses (1983) J Prosthet Dent, 49, pp. 843-848 | |
| dc.description | Cibirka, R.M., Razzoog, M.E., Lang, B.R., Determining the force absorption quotient for restorative materials used in implant occlusal surfaces (1992) J Prosthet Dent, 67, pp. 361-364 | |
| dc.description | Stegaroiu, R., Kusakari, H., Nishiyama, S., Influence of prosthesis material on stress distribution in bone and implant: a 3-dimensional finite element analysis (1998) Int J Oral Maxillofac Implants, 13, pp. 781-790 | |
| dc.description | Inan, O., Kesim, B., Evaluation of the effects of restorative materials used for occlusal surfaces of implant-supported prostheses on force distribution (1999) Implant Dent, 8, pp. 311-316 | |
| dc.description | Soumeire, J., Dejou, J., Shock absorbability of various restorative materials used on implants (1999) J Oral Rehabil, 26, pp. 394-401 | |
| dc.description | Vigolo, P., Majzoub, Z., Cordioli, G., Measurement of the dimensions and abutment rotational freedom of gold-machined 3i UCLA-type abutments in the as-received condition, after casting with a noble metal alloy and porcelain firing (2000) J Prosthet Dent, 84, pp. 548-553 | |
| dc.description | Ciftci, Y., Canay, S., Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials (2001) Int J Prosthodont, 14, pp. 406-411 | |
| dc.description | Wang, T.M., Leu, L.J., Wang, J., Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis (2002) Int J Oral Maxillofac Implants, 17, pp. 231-237 | |
| dc.description | Fonseca, J.C., Henriques, G.E., Sobrinho, L.C., Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings (2003) Dent Mater, 19, pp. 686-691 | |
| dc.description | Koke, U., Wolf, A., Lenz, P., In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures (2004) J Oral Rehabil, 31, pp. 477-482 | |
| dc.description | Karl, M., Rosch, S., Graef, F., Static implant loading caused by as-cast metal and ceramic-veneered superstructures (2005) J Prosthet Dent, 93, pp. 324-330 | |
| dc.description | Ortorp, A., Jemt, T., Wennerberg, A., Screw preloads and measurements of surface roughness in screw joints: an in vitro study on implant frameworks (2005) Clin Implant Dent Relat Res, 7, pp. 141-149 | |
| dc.description | Hecker, D.M., Eckert, S.E., Cyclic loading of implant-supported prostheses: changes in component fit over time (2003) J Prosthet Dent, 89, pp. 346-351 | |
| dc.description | Sartori, I.A., Ribeiro, R.F., Francischone, C.E., In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion (2004) J Prosthet Dent, 92, pp. 132-138 | |
| dc.description | Kucey, B.K., Fraser, D.C., The Procera abutment-the fifth generation abutment for dental implants (2000) J Can Dent Assoc, 66, pp. 445-449 | |
| dc.description | Garine, W.N., Funkenbusch, P.D., Ercoli, C., Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments (2007) Int J Oral Maxillofac Implants, 22, pp. 928-938 | |
| dc.description | Vult von Steyern, P., Ebbesson, S., Holmgren, J., Fracture strength of two oxide ceramic crown systems after cyclic pre-loading and thermocycling (2006) J Oral Rehabil, 33, pp. 682-689 | |
| dc.description | Shirakura, A., Lee, H., Geminiani, A., The influence of veneering porcelain thickness of all-ceramic and metal ceramic crowns on failure resistance after cyclic loading (2009) J Prosthet Dent, 101, pp. 119-127 | |
| dc.description | Karl, M., Graef, F., Taylor, T.D., In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorations (2007) J Prosthet Dent, 97, pp. 137-140 | |
| dc.description | Assunção, W.G., Delben, J.A., Tabata, L.F., Effect of vertical misfit on screw joint stability of implant-supported crowns (2011) J Mater Eng Perform, 20, pp. 947-951 | |
| dc.description | Shigley, J.E., Mischke, C.R., (2001) Mechanical Engineering Design, , New York, McGraw Hill | |
| dc.language | en | |
| dc.publisher | | |
| dc.relation | Journal of Prosthodontics | |
| dc.rights | fechado | |
| dc.source | Scopus | |
| dc.title | Influence Of Abutment Type And Esthetic Veneering On Preload Maintenance Of Abutment Screw Of Implant-supported Crowns | |
| dc.type | Artículos de revistas | |