dc.creatorRocha H.S.
dc.creatorPereira G.R.
dc.creatorFaria P.
dc.creatorKellermann G.
dc.creatorMazzaro I.
dc.creatorTirao G.
dc.creatorGiles C.
dc.creatorLopes R.T.
dc.date2008
dc.date2015-06-30T19:18:59Z
dc.date2015-11-26T14:41:58Z
dc.date2015-06-30T19:18:59Z
dc.date2015-11-26T14:41:58Z
dc.date.accessioned2018-03-28T21:49:16Z
dc.date.available2018-03-28T21:49:16Z
dc.identifier
dc.identifierEuropean Journal Of Radiology. , v. 68, n. 3 SUPPL., p. 37 - 40, 2008.
dc.identifier0720048X
dc.identifier10.1016/j.ejrad.2008.04.032
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-56549113537&partnerID=40&md5=429b5225951dedf2328faaf8f9ecc631
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/105727
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/105727
dc.identifier2-s2.0-56549113537
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1251076
dc.descriptionThe diffraction-enhanced imaging (DEI) is a powerful tool to observe tumors and other diseases in breast tissue and provide more precise diagnostics. In this work DEI was used to analyze breast tissues details that have poor attenuation contrast. An X-ray imaging system with DEI techniques was developed using synchrotron radiation. The DEI experiment was performed in D10A-XRD2 beamline at the Brazilian Synchrotron-LNLS. The pre-monochromator, upstream of the beamline was adjusted to 10.7 keV. The samples were positioned between two channel-cut Si(3 3 3) in non-dispersive geometry mounted in a double axes diffractometer. A direct conversion water-cooled CCD camera of 1242 pixel × 1152 pixel of 25 μm × 25 μm each was used as a two-dimensional detector in scanning mode. The DEI system could show details in low attenuation tissues based on the contrast imaging obtained by attenuation, refraction gradient and ultra-small angle scatter characteristics. In this work the capacity to observe different types of structures and details in breast tissues were investigated. © 2008 Elsevier Ireland Ltd. All rights reserved.
dc.description68
dc.description3 SUPPL.
dc.description37
dc.description40
dc.descriptionChapman, D., Thomlinson, W., Johnston, R., Diffraction enhanced X-ray imaging (1997) Phys Med Biol, 42, pp. 2015-2025
dc.descriptionHasnah, M., Oltulu, O., Zhong, Z., Chapman, D., Application of absorption and refraction matching techniques for diffraction enhanced imaging (2002) Rev Sci Instrum, 73, pp. 1657-1659
dc.descriptionLagomarsino, S., Cedola, A., X-ray microscopy and nanodiffraction (2004) Encyclopedia Nanosci Nanotechnol, 10, pp. 681-710
dc.descriptionIngal, V.N., Beliaevskaya, E.A., X-ray plane-wave topography observation of the phase contrast from a non-crystalline object (1995) J Phys D: Appl Phys, 28, pp. 2314-2317
dc.descriptionDavis, T.J., Gao, D., Gureyev, T.E., Stevenson, A.W., Wilkins, S.W., X-ray image contrast from a simple phase object (1995) Nature, 373, pp. 595-598
dc.descriptionMenk, R.H., Rigon, L., Arfelli, F., Diffraction-enhanced X-ray medical imaging at the ELETTRA synchrotron light source (2005) Nucl Instrum Methods Phys Res A, 548, pp. 213-220
dc.descriptionDilmanian, F.A., Zhong, Z., Ren, B., Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method (2000) Phys Med Biol, 45, pp. 933-946
dc.descriptionZhong, Z., Thomlinson, W., Chapman, D., Sayers, D., Implementation of diffraction-enhanced experiments: at the NSLS and APS (2000) Nucl Instrum Methods Phys Res A, 450, pp. 556-567
dc.descriptionRigon, L., Besch, H., Arfelli, F., A new DEI algorithm capable of investigating sub-pixel structures (2003) J Phys D: Appl Phys, 36, pp. A107-A112
dc.descriptionGiles, C., Hönnicke, M.G., Lopes, R.T., First experiments on diffraction-enhanced imaging at LNLS (2003) J Synchrotron Radiat, 10, pp. 421-423
dc.descriptionRocha, H.S., Lopes, R.T., Valiante, P.M., Diagnosis of thyroid multinodular goiter using diffraction-enhanced imaging (2005) Nucl Instrum Methods Phys Res A, 548, pp. 175-180
dc.descriptionRocha, H.S., Lopes, R.T., Pessôa, L.M., Diffraction-Enhanced Imaging for studying pattern recognition in cranial ontogeny of bats and marsupials (2005) Nucl Instrum Methods Phys Res A, 548, pp. 228-233
dc.languageen
dc.publisher
dc.relationEuropean Journal of Radiology
dc.rightsfechado
dc.sourceScopus
dc.titleDiffraction-enhanced Imaging Microradiography Applied In Breast Samples
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución