dc.creatorDe Marco F.A.
dc.creatorRisso-Neto M.I.
dc.creatorCavali P.T.M.
dc.creatorSussi M.A.
dc.creatorPasqualini W.
dc.creatorLandim E.
dc.creatorVeiga I.G.
dc.creatorLehoczki M.A.
dc.creatorFilho A.C.A.
dc.date2008
dc.date2015-06-30T19:16:37Z
dc.date2015-11-26T14:41:11Z
dc.date2015-06-30T19:16:37Z
dc.date2015-11-26T14:41:11Z
dc.date.accessioned2018-03-28T21:47:57Z
dc.date.available2018-03-28T21:47:57Z
dc.identifier
dc.identifierColuna/ Columna. , v. 7, n. 1, p. 1 - 7, 2008.
dc.identifier18081851
dc.identifier
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-42249111182&partnerID=40&md5=7a6ab46dcf2b08ae29ac58882230f95b
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/105543
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/105543
dc.identifier2-s2.0-42249111182
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1250739
dc.descriptionObjective: pedicular screw technique has becoming the standard choice for spinal fixation. The goal of the study is to evaluate thoracic and lumbar pedicle screws placement to treat a variety of spinal disorders. These screws were inserted using intrapperative anatomical and fluoroscopic parameters. Methods: the retrospective analysis included 24 patients (7 men and 17 women with a mean age of 34.6 years), the radiograms and the computed tomograms. They were operated due some spinal disease using pedicle screws from T2 to S1 totalizing 183 pedicular screws. The screw insertion technique is based on the intraoperative anatomic and fluoroscopic parameters. The exams were analyzed by three orthopaedic spinal surgeons and one radiologist looking for any cortical violation. When they found any cortical violation until 2mm the screw position was considered acceptable. Results: pedicle screws perforations were seen in 36.06% but only 3.82 % were classified as not acceptable. It was observed 96.18% of screws without or with minimal violation which does not cause any risk of visceral, nervous or vascular lesion. In the violated pedicles. It was seen 63.64% of lateral, 19.69% of medial and 16,66% of anterior perforation. There were no superior or inferior violations. Conclusion: thoracic and lumbar pedicle screw fixation placed based on anatomic and fluoroscopic parameters is a safer and an eftective method for different spine levels in the treatment of a variety of spinal disorders.
dc.description7
dc.description1
dc.description1
dc.description7
dc.descriptionKim, Y.J., Lenke, L.G., Cheh, G., Riew, K.D., Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: A comparison with computerized tomograpy (2005) Spine, 30 (18), pp. 2084-2088
dc.descriptionOdgers 4th, C.J., Vaccaro, A.R., Pollak, M.E., Cotler, J.M., Accuracy of pedicle screw placement with the assistance of lateral plain radiography (1996) J Spinal Disord, 9 (4), pp. 334-338
dc.descriptionCarbone, J.J., Tortolani, P.J., Quartararo, L.G., Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: Technique and short-term complications (2003) Spine, 28 (1), pp. 91-97
dc.descriptionCastro, W.H., Halm, H., Jerosch, J., Malms, J., Steinbeck, J., Blasius, S., Accuracy of pedicle screw placement in lumbar vertebrae (1996) Spine, 21 (11), pp. 1320-1324
dc.descriptionSapkas, G.S., Papadakis, S.A., Satathakopoulos, D.P., Papagelopoulos, P.J., Badekas, A.C., Kaiser, J.H., Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography. A prospective study of 35 patients (1999) Spine, 24 (18), pp. 1926-1929
dc.descriptionYoukilis, A.S., Quint, D.J., McGillicuddy, J.E., Papadoupoulos, S.M., Stereotactic navigation for placement of pedicle screws in the thoracic spine (2001) Neurosurgery, 48 (4), pp. 771-778. , discussion 778-9
dc.descriptionLiljenqvist, U.R., Halm, H.F., Link, T.M., Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis (1997) Spine, 22 (19), pp. 2239-2245
dc.descriptionKim, Y.J., Lenke, L.G., Bridwell, K.H., Cho, Y.F., Riew, K.D., Free hand pedicle screw placement in thoracic spine: Is it safe? (2004) Spine, 29 (3), pp. 333-342. , discussion 342
dc.descriptionBelmont Jr, P.J., Klemme, W.R., Dhawan, A., Polly Jr., D.W., In vivo accuracy of thoracic pedicle screws (2001) Spine, 26 (21), pp. 2340-2346
dc.descriptionGertzbein, S.D., Robbins, S.E., Accuracy of pedicular screw placement in vivo (1990) Spine, 15 (1), pp. 11-14
dc.descriptionSuk, S.I., Kim, W.J., Lee, S.M., Kim, J.H., Chung, E.R., Thoracic pedicle screw fixation in spinal deformities: Are they really safe? (2001) Spine, 26 (18), pp. 2049-2057
dc.descriptionGrauer, J.N., Vaccaro, A.R., Brusovanik, G., Girardi, F.P., Silveri, C.P., Cammisa, F.P., Evaluation of a novel pedicle probe for the placement of thoracic and lumbosacral pedicle screws (2004) J Spinal Disord Tech, 17 (6), pp. 492-497
dc.descriptionDefino, H.L.A., Mauad Filho, J., Estudo morfométrico do pedículo das vértebras torácicas e lombares. (1999) Rev Bras Ortop, 34 (2), pp. 97-108
dc.descriptionCinotti, G., Gumina, S., Ripani, M., Postacchini, F., Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws (1999) Spine, 24 (2), pp. 114-119
dc.descriptionEbraheim, N.A., Jabaly, G., Xu, R., Yeasting, R.A., Anatomic relations of the thoracic pedicle to the adjacent neural structures (1997) Spine, 22 (14), pp. 1553-1556. , discussion 1557
dc.descriptionBoachie-Adjei, O., Girardi, F.P., Bansal, M., Rawlins, B.A., Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle- probing conventional anatomic technique (2000) J Spinal Disord, 13 (6), pp. 496-500
dc.descriptionRao, G., Brodke, D.S., Rondina, M., Dailey, A.T., Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement (2002) J Neurosurg, 97 (2 SUPPL.), pp. 223-226
dc.descriptionUl Haque, M., Shufflebarger, H.L., O'Brien, M., Macagno, A., Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: Is fluoroscopy safe? (2006) Spine, 31 (21), pp. 2516-2520
dc.descriptionRoy-Camille, R., Saillant, G., Mazel, C., Internal fixation of the lumbar spine with pedicle screw plating (1986) Clin Orthop Relat Res, 203, pp. 7-17
dc.descriptionVaccaro, A.R., Rizzolo, S.J., Balderston, R.A., Allardyce, T.J., Garfin, S.R., Dolinskas, C., An, H.S., Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment (1995) J Bone Joint Surg Am, 77 (8), pp. 1200-1206
dc.languagept
dc.publisher
dc.relationColuna/ Columna
dc.rightsaberto
dc.sourceScopus
dc.titlePlacement Analysis Of Thoracic And Lumbar Pedicle Screws Inserted Under Anatomic And Radioscopic Parameters [avaliação Posicionamento De Parafusos Pediculares Na Coluna Torácica E Lombar Introduzidos Com Base Em Referenciais Anatômicos E Radioscópicos]
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución