dc.creatorKiyataka P.H.M.
dc.creatorDantas S.T.
dc.creatorPallone J.A.L.
dc.date2014
dc.date2015-06-25T17:55:21Z
dc.date2015-11-26T14:38:08Z
dc.date2015-06-25T17:55:21Z
dc.date2015-11-26T14:38:08Z
dc.date.accessioned2018-03-28T21:42:58Z
dc.date.available2018-03-28T21:42:58Z
dc.identifier
dc.identifierFood Additives And Contaminants - Part A Chemistry, Analysis, Control, Exposure And Risk Assessment. , v. 31, n. 1, p. 156 - 163, 2014.
dc.identifier19440049
dc.identifier10.1080/19440049.2013.855826
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-84893644654&partnerID=40&md5=823e532d3b280a5a0d3af4e53c588dfa
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/86811
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/86811
dc.identifier2-s2.0-84893644654
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1249449
dc.descriptionThe purpose of this paper was to assess the concentration of lead (Pb), cadmium (Cd), mercury (Hg) and arsenic (As) in high-density polyethylene (HDPE) packaging intended for contact with yoghurt and the migration of these elements using the food itself and 3% acetic acid as a food simulant in accordance to ANVISA, the Brazilian Health Surveillance Agency. In order to perform this study, it was necessary to develop and validate a method by inductively coupled plasma optical emission spectroscopy (ICP-OES) analysis. For method validation, the parameters linearity, limits of detection (LODs) and quantification (LOQs), accuracy and precision were determined. Fifteen commercial samples of yoghurt, marketed in Campinas - São Paulo (Brazil), were used for the analysis. The packaging and yoghurt were digested in high-pressure ashing equipment (HPA) and the migration of the elements into simulant were determined directly in the solution. The validated method proved adequate and the results obtained showed that all the packaging had levels of Hg and Cd below the LOQ, corresponding to 1.0 and 1.5 μg l-1, respectively. The highest levels of As and Pb were 0.87 and 462.3 mg kg-1, respectively. The migration of these elements to the yoghurt after 45 days of contact at 4°C was below the LOQ for all the samples assessed. The results of specific migration into 3% acetic acid simulant showed the concentrations of Cd, Hg and As below 5, 5 and 10 μg kg-1, respectively, which are the maximum limits set by ANVISA. However, for three samples the packaging lid showed migration of Pb into simulant ranging from 30.6 to 40.2 μg kg-1, exceeding the limit set by ANVISA of 10 μg kg-1. © 2014 Taylor & Francis.
dc.description31
dc.description1
dc.description156
dc.description163
dc.description(2013) Appendix K: Guidelines for dietary supplements and botanicals, , http://www.eoma.aoac.org/app_k.pdf, AOAC
dc.description(2008) Resolução RDC n. 17 de 17 de março de 2008. Dispõe sobre regulamento técnico sobre lista positiva de aditivos para materiais plásticos destinados à elaboração de embalagens e equipamentos em contato com alimentos, , Brasil, Brasília, DF,: Diário Oficial da União
dc.description(2010) Resolução RDC n. 52 de 26 de novembro de 2010. Dispõe sobre corantes em embalagens e equipamentos plásticos destinados a entrar em contato com alimentos, , Brasil, Brasília, DF,: Diário Oficial da União
dc.descriptionButcher, D.J., Review: recent advances in optical analytical atomic spectrometry (2013) Appl Spectrosc Rev, 48, pp. 261-328
dc.descriptionButler, O.T., Cairns, W.R.L., Cook, J.M., Davidson, C.M., Atomic spectrometry update. Environmental analysis (2012) J Anal At Spectrom, 27, pp. 187-221
dc.descriptionCadore, S., Matoso, E., Santos, M.C., A espectrometria atômica e a determinação de elementos metálicos em material polimérico (2008) Química Nova, 31, pp. 1533-1542
dc.descriptionIogurte líquido [Internet], , http://www.datamark.com.br/, DATAMARK
dc.descriptionDemirel, S., Tuzen, M., Saracoglu, S., Soylak, M., Evaluation of various digestion procedures for trace element contents of some food materials (2008) J Hazard Mater, 152, pp. 1020-1026
dc.descriptionErnst, T., Popp, R., Eldik, R.V., Quantification of heavy metals for the recycling of waste plastics from electrotechnical applications (2000) Talanta, 53, pp. 347-357
dc.description(2002) European Committee for Standardization
dc.descriptionFordham, P.J., Gramshaw, J.W., Crews, H.M., Castle, L., Element residues in food contact plastics and their migration into food simulants, measured by inductively-coupled plasma-mass spectrometry (1995) Food Addit Contam, 12, pp. 651-669
dc.descriptionGouveia, S.T., Silva, F.V., Costa, L.M., Nogueira, A.R.A., Nóbrega, J.A., Determination of residual carbon by inductively-coupled plasma optical emission spectrometry with axial and radial view configurations (2001) Anal Chim Acta, 445, pp. 269-275
dc.descriptionGrob, K., Stocker, J., Colwell, R., Assurance of compliance within the production chain of food contact materials by good manufacturing practice and documentation - Part 1: Legal background I Europe and compliance challenges (2008) Food Contr, 20, pp. 476-482
dc.descriptionGuerra, M.B.B., Carapelli, R., Miranda, K., Nogueira, A.R.A., Filho, E.R.P., Determination of As and Sb in mineral waters by fast sequential continuous flow hydride generation atomic absorption spectrometry (2011) Anal Method, 3, pp. 599-605
dc.descriptionHaldimann, M., Alt, A., Blanc, A., Brunner, K., Sager, F., Dudler, V., Migration of antimony from PET trays into food simulant and food: determination of Arrhenius parameters and comparison of predicted and measured migration data (2013) Food Addit Contam Part A, 30, pp. 587-598
dc.descriptionHorwitz, W., Evaluation of analytical methods used for regulation of foods and drugs (1982) Anal Chem, 54, pp. 67-76
dc.description(2011) Inmetro., , http://www.inmetro.gov.br/sidoq/arquivos/Cgcre/DOQ/DOQ-Cgcre-8_04.pdf
dc.descriptionKorn, M.G.A., Morte, E., Santos, D.C.M.B., Castro, J., Barbosa, J., Teixeira, A., Fernandes, A., Korn, M., Sample preparation for the determination of metals in food samples using spectroanalytical methods: a review (2008) Appl Spectrosc Rev, 43, pp. 67-92
dc.descriptionKrug, F.J., (2008) Métodos de preparo de amostras: Fundamentos sobre preparo de amostras orgânicas e inorgânicas para análise elementar, , Piracicaba,: USP
dc.descriptionMunoz, P.H., Catalá, R., Gavara, R., Simple method for the selection of the appropriate food simulant for the evaluation of a specific food/packaging interaction (2002) Food Addit Contam Part A, 19, pp. 192-200
dc.descriptionNomura, D.H., Mateus, S.F., Saiki, M., Bode, P., Characterization of inorganic components in plastic materials (2000) J Radioanal Nucl Chem, 244, pp. 61-65
dc.descriptionOliveira, L.M., Queiroz, G.C., (2008) Embalagens plásticas rígidas: Principais polímeros e avaliação da qualidade, , Campinas,: ITAL/CETEA
dc.descriptionÖzer, E.T., Çimenoglub, M.A., Güçerab, S., Determination of cadmium, chromium, lead, and mercury in polyethylene and polypropylene after xylene treatment by energy dispersive X-ray fluorescence spectrometry (2011) Instrum Sci Technol, 39, pp. 357-367
dc.descriptionPerring, L., Alonso, M.I., Andrey, D., Bourqui, B., Zbinden, P., An evaluation of analytical techniques for determination of lead, cadmium, chromium, and mercury in food-packaging materials (2001) Fresenius J Anal Chem, 370, pp. 76-81
dc.descriptionReinas, I., Oliveira, J., Pereira, J., Machado, F., Poças, M.F., Migration of two antioxidants from packaging into solid food and into Tenax (2012) Food Contr, 28, pp. 333-337
dc.descriptionRitter, A., Michel, E., Schmid, M., Affolter, S., Interlaboratory test on polymers: determination of heavy metals in polymer matrices (2004) Polymer Testing, 23, pp. 467-474
dc.descriptionSakurai, H., Noro, J., Kawase, A., Fujinami, M., Oguma, K., Digestion of plastic materials for the determination of toxic metals with a microwave oven for household use (2006) Anal Sci, 22, pp. 225-228
dc.descriptionSimoneau, C., Van den Eede, L., Valzacchi, S., Identification and quantification of the migration of chemicals from plastic baby bottles used as substitutes for polycarbonate (2012) Food Addit Contam Part A, 29, pp. 469-480
dc.descriptionSneddon, J., Hardaway, C., Bobbadi, K.K., Reddy, A.K., Sample preparation of solid samples for metal determination by atomic spectroscopy: an overview and selected recent applications (2006) Appl Spectrosc Rev, 41, pp. 1-14
dc.descriptionSoares, E.P., Saiki, M., Wiebeck, H., Determination of inorganic constituents and polymers in metalized plastic materials (2005) J Radioanal Nucl Chem, 264, pp. 9-13
dc.descriptionVan Goetz, N., Fabricius, L., Glaus, R., Weitbrecht, V., Günther, D., Hungerbühler, K., Migration of silver from commercial plastic food containers and implications for consumer exposure assessment (2013) Food Addit Contam Part A, 30, pp. 612-620
dc.descriptionWhite, R.T., Kettisch, P., Kainrath, P., The high pressure asher: a high-performance sample decomposition system as an alternative to microwave-assisted digestion (1998) Atomic Spectrosc, 19, pp. 187-192
dc.descriptionZenebon, O., Murata, L.T.F., Pascuet, N., Alcântara, M.R.S., Nunes, M.C.D., Ribeiro, E.R., Tiglea, P., Determinação de metais presentes em corantes e pigmentos utilizados em embalagens para alimentos (2004) Revista do Instituto Adolfo Lutz, 63, pp. 56-62
dc.languageen
dc.publisher
dc.relationFood Additives and Contaminants - Part A Chemistry, Analysis, Control, Exposure and Risk Assessment
dc.rightsfechado
dc.sourceScopus
dc.titleMethod For Assessing Lead, Cadmium, Mercury And Arsenic In High-density Polyethylene Packaging And Study Of The Migration Into Yoghurt And Simulant
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución