dc.creatorMilagres B.G.
dc.creatorDe Oliveira Neto G.
dc.creatorKubota L.T.
dc.creatorYamanaka H.
dc.date1997
dc.date2015-06-30T14:47:15Z
dc.date2015-11-26T14:34:31Z
dc.date2015-06-30T14:47:15Z
dc.date2015-11-26T14:34:31Z
dc.date.accessioned2018-03-28T21:37:55Z
dc.date.available2018-03-28T21:37:55Z
dc.identifier
dc.identifierAnalytica Chimica Acta. , v. 347, n. 01/02/15, p. 35 - 41, 1997.
dc.identifier32670
dc.identifier10.1016/S0003-2670(97)00105-0
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-0030842924&partnerID=40&md5=c379cd91bbeb14f255c6050a41f3375e
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/99966
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/99966
dc.identifier2-s2.0-0030842924
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1248127
dc.descriptionAn amperometric biosensor for salicylate detection was developed by immobilizing salicylate hydroxylase via glutaraldehyde onto a polypyrrole film doped with hexacyanoferrate, supported on a glassy carbon electrode surface. The sensor monitors the catechol produced in the enzymatic reaction on the film surface, at an applied potential of 150 mV vs. SCE. A [NADH]/[salicylate] ratio between 2 and 4 gave the best response. The biosensor presented the best performance in a solution with pH=7.4. The response time was about 40 s. A linear range of response was observed for salicylate concentrations between 1.0x10-5 and 1.0x10-4 mol l-1 and the equation adjusted for this curve was I=(-0.04±0.01)+(11.4±0.2)[salicylate] with a correlation coefficient of 0.999 for n=6. The biosensor retains its activity for at least 10 days despite daily use. The results obtained using the biosensor for salicylate determination, in three different samples of antithermic drugs, presented a good correlation with the standard colorimetric method.
dc.description347
dc.description01/02/15
dc.description35
dc.description41
dc.descriptionFrew, J.E., Bayliff, S.W., Gibbs, P.N.B., Green, M.J., (1989) Anal. Chim. Acta, 273, p. 39
dc.descriptionRainsdorf, K.D., (1984) Aspirin and the Salicylates, pp. 56-58. , Butterworths, London, UK
dc.descriptionChem, B.E., Johns, D., Bochner, F., Imhoff, O.M., Rowland, M., (1979) Clin. Chem., 25, p. 1420
dc.descriptionKwong, T.C., (1985) Clin. Chem. News, 1, p. 14
dc.descriptionKang, E.S., Todd, T.A., Capaci, M.T., Schwenzer, K., Jabbour, J.T., (1983) Clin. Chem., 29, p. 1012
dc.descriptionStewart, M.J., Watson, I.D., (1987) Ann. Clin. Biochem., 24, p. 552
dc.descriptionRivas, G.A., Calatayud, J.M., (1995) Talanta, 42, p. 1285
dc.descriptionBertocchi, P.B., D'Ottavio, D., Evangelist, M.E., Mascini, M., Palleschi, G., (1992) Clin. Chim. Acta, 207, p. 205
dc.descriptionYou, K.S., Bitticofer, J.A., (1984) Clin. Chem., 30, p. 1549
dc.descriptionSaha, U., Baksi, K., (1985) Analyst, 110, p. 739
dc.descriptionPulgarin, J.A.M., Molina, A.A., (1994) Analyst, 119, p. 1915
dc.descriptionVillari, A., Micali, N., Frest, M., Puglisi, G., (1994) Analyst, 119, p. 1561
dc.descriptionCarlson, M., Thompson, R.D., (1987) J. Liquid Chromathogr., 10, p. 997
dc.descriptionBuskin, J.N., Upton, R.A., William, R.L., (1982) Clin. Chem., 28, p. 1200
dc.descriptionPapaglou, A.M., Diamandis, E.P., Hadjiioannou, T.P., (1984) Anal. Chim. Acta, 159, p. 393
dc.descriptionHassan, S.M., Hamada, M.A., (1988) Analyst, 113, p. 1709
dc.descriptionGilmartin, M.A.T., Hart, J.P., (1995) Anal. Proc., 32, p. 341
dc.descriptionMoore, T.J., Joseph, M.J., Allen, B.W., Coury, L.A., (1995) Anal. Chem., 67, p. 1896
dc.descriptionNeumayr, M., Friedrich, O., Sontag, G., (1993) Anal. Chim. Acta, 273, p. 469
dc.descriptionRahni, M.A.N., Guilbault, G.G., De Oliveira Neto, G., (1986) Anal. Chim. Acta, 181, p. 219
dc.descriptionGorton, L., Bremle, G., Csoregi, E., Pettersson, G.J., Persson, B., (1991) Anal. Chim. Acta, 249, p. 43
dc.descriptionYou, K.S., (1985) Clin. Chim. Acta, 149, p. 281
dc.descriptionNeumayr, M., Sontag, G., Pittner, F., (1995) Anal. Chim. Acta, 305, p. 26
dc.descriptionFonong, T., Rechnitz, G.A., (1984) Anal. Chim. Acta, 158, p. 357
dc.descriptionGorton, L., (1995) Electroanalysis, 7, p. 23
dc.descriptionGorton, L., Karan, H.J., Hale, P.D., Inagaki, T., Okamoto, Y., Skothein, T.A., (1990) Anal. Chim. Acta, 228, p. 23
dc.descriptionWang, J., Wu, L.H., Lu, Z., Li, R., Sanches, J., (1990) Anal. Chim. Acta, 228, p. 251
dc.descriptionBorges, C.G., De Oliveira Neto, G., Kubota, L.T., Grandin, L., (1996) J. Electroanal. Chem., 418, p. 147
dc.descriptionKubota, L.T., Milagres, B.G., Gouveia, F., De Oliveira Neto, G., (1996) Anal. Lett., 29, p. 893
dc.descriptionDong, S., Ding, J., (1988) Synth. Metals, 24, p. 273
dc.descriptionVan Dyke, L.S., Martin, C.R., (1990) Synth. Metals, 36, p. 275
dc.descriptionLever, A.B.P., (1990) Inorg. Chem., 29, p. 1271
dc.descriptionMurray, R.W., Chemically modified electrodes (1984) Electroanalytical Chemistry, 13, pp. 191-368. , A.J. Bard (Ed.), Marcel Dekker Inc., NY
dc.descriptionChoi, K.K., Fung, K.W., (1982) Anal. Chim. Acta, 138, p. 385
dc.languageen
dc.publisher
dc.relationAnalytica Chimica Acta
dc.rightsfechado
dc.sourceScopus
dc.titleA New Amperometric Biosensor For Salicylate Based On Salicylate Hydroxylase Immobilized On Polipyrrole Film Doped With Hexacyanoferrate
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución