Artículos de revistas
Biomechanical Evaluation Of Subcrestal Dental Implants With Different Bone Anchorages
Registro en:
Brazilian Oral Research. Sociedade Brasileira De Hematologia E Hemoterapia, v. 28, n. 1, p. 1 - 7, 2014.
18068324
10.1590/1807-3107BOR-2014
2-s2.0-84913537858
Autor
Sotto-Maior B.S.
Lima C.A.
Senna P.M.
Camargos G.V.
Del Bel Cury A.A.
Institución
Resumen
This study evaluated the biomechanical influence of apical bone anchorage on a single subcrestal dental implant using three-dimensional finite element analysis (FEA). Four different bone anchorage designs were simulated on a posterior maxillary segment using one implant with platform switching and internal Morse taper connection as follows: 2 mm subcrestal placement with (SW) or without (SO) the implant apex engaged into the cortical bone or position at bone level with anchorage only in the crestal cortical (BO) bone or with bicortical fixation (BW). Each implant received a premolar crown, and all models were loaded with 200 N to simulate centric and eccentric occlusion. The peak tensile and compressive stress and strain were calculated at the crestal cortical, trabecular, and apical cortical bone. The vertical and horizontal implant displacements were measured at the platform level. FEA indicated that subcrestal placement (SW and SO) created lower stress and strain in the crestal cortical bone compared with crestal placement (BO and BW models). The SW model exhibited lesser vertical and horizontal implant micromovement compared with the SO and BO models under eccentric loading; however, stress and strain were higher in the apical cortical bone. The BW model exhibited the lowest implant displacement. These results indicate that subcrestal placement decreases the stress in the crestal cortical bone of dental implants, regardless of apical anchorage however, apical cortical anchorage can be effective in limiting implant displacement. Further studies are required to evaluate the effects of possible remodeling around the apex on the success of subcrestal implants. 28 1 1 7 Javed, F., Romanos, G.E., The role of primary stability for successful immediate loading of dental implants (2010) A literature review. J Dent., 38 (8), pp. 612-620 Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., Dubruille, J.H., Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature (1998) J Biomed Mater Res., 43 (2), pp. 192-203. , Summer Devlin, H., Horner, K., Ledgerton, D., A comparison of maxillary and mandibular bone mineral densities (1998) J Prosthet Dent., 79 (3), pp. 323-327. , Mar Tran, B.L., Chen, S.T., Caiafa, A., Davies, H.M., Darby, I.B., Transmucosal healing around peri-implant defects: crestal and subcrestal implant placement in dogs (2010) Clin Oral Implants Res, 21 (8), pp. 794-803 Hammerle, C.H., Bragger, U., Burgin, W., Lang, N.P., The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues (1996) Clin Oral Implants Res., 7 (2), pp. 111-119. , Jun Donovan, R., Fetner, A., Koutouzis, T., Lundgren, T., Crestal bone changes around implants with reduced abutment diameter placed non-submerged and at subcrestal positions: a 1-year radiographic evaluation (2010) J Periodontol, 81 (3), pp. 428-434 Barros, R.R., Novaes Jr, A.B., Muglia, V.A., Lezzi, G., Piattelli, A., Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded morse cone connection implants: a histomorphometric study in dogs (2010) Clin Oral Implants Res., 21 (4), pp. 371-378. , Apr 1 Huang, B., Meng, H., Piao, M., Xu, L., Zhang, L., Zhu, W., Influence of placement depth on bone remodeling around tapered internal connection implant: a clinical and radiographic study in dogs (2012) J Periodontol, 83 (9), pp. 1164-1171 Canullo, L., Pace, F., Coelho, P., Sciubba, E., Vozza, I., The influence of platform switching on the biomechanical aspects of the implant-abutment system.A three dimensional finite element study. (2011) Med Oral Patol Oral Cir Bucal., 16 (6), pp. e852-e856 Huang, C.C., Lan, T.H., Lee, H.E., Wang, C.H., The biomechanical analysis of relative position between implant and alveolar bone: finite element method (2011) J Periodontol, 82 (3), pp. 489-496 Chou, H.Y., Muftu, S., Bozkaya, D., Combined effects of implant insertion depth and alveolar bone quality on periimplant bone strain induced by a wide-diameter, short implant and a narrowdiameter, long implant (2010) J Prosthet Dent, 104 (5), pp. 293-300 Baggi, L., Cappelloni, I., Di Girolamo, M., Maceri, F., Vairo, G., The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis. (2008) J Prosthet Dent., 100 (6), pp. 422-431 Ahn, S.J., Leesungbok, R., Lee, S.W., Heo, Y.K., Kang, K.L., Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study (2012) J Prosthet Dent, 107 (6), pp. 366-372 Katranji, A., Misch, K., Wang, H.L., Cortical bone thickness in dentate and edentulous human cadavers (2007) J Periodontol, 78 (5), pp. 874-878 Ausiello, P., Apicella, A., Davidson, C.L., Effect of adhesive layer properties on stress distribution in composite restorations--a [3D] finite element analysis (2002) Dent Mater, 18 (4), pp. 295-303 Sevimay, M., Turhan, F., Kilicarslan, M.A., Eskitascioglu, G., Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implantsupported crown (2005) J Prosthet Dent, 93 (3), pp. 227-234 Huang, H.L., Hsu, J.T., Fuh, L.J., Lin, D.J., Chen, M.Y., Biomechanical simulation of various surface roughnesses and geometric designs on an immediately loaded dental implant (2010) Comput Biol Med, 40 (5), pp. 525-532 Hattori, Y., Satoh, C., Kunieda, T., Endoh, R., Hisamatsu, H., Watanabe, M., Bite forces and their resultants during forceful intercuspal clenching in humans (2009) J Biomech, 42 (10), pp. 1533-1538 Clelland, N.L., Lee, J.K., Bimbenet, O.C., Gilat, A., Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant (1993) J Prosthodont, 2 (3), pp. 183-189 Frost, H.M., A 2003 update of bone physiology and Wolff's law for clinicians (2004) Angle Orthod, 74 (1), pp. 3-15 Natali, A.N., Hart, R.T., Pavan, P.G., Knets, I., Mechanics of bone tissue (2003), pp. 1-19. , Natali AN, editor. Dental biomechanics. London: Taylor & Francis;Lee, E.H., Ryu, S.M., Kim, J.Y., Cho, B.O., Lee, Y.C., Park, Y.J., Effects of installation depth on survival of an hydroxyapatite-coated bicon implant for single-tooth restoration (2010) J Oral Maxillofac Surg, 68 (6), pp. 1345-1352 Weinberg, L.A., Reduction of implant loading using a modified centric occlusal anatomy (1998) Int J Prosthodont, 11 (1), pp. 55-69. , Jan-Feb Carter, D.R., Caler, W.E., Spengler, D.M., Frankel, V.H., Fatigue behavior of adult cortical bone: the influence of mean strain and strain range (1981) Acta Orthop Scand, 52 (5), pp. 481-490 Sato, M., Ochi, T., Nakase, T., Hirota, S., Kitamura, Y., Nomura, S., Mechanical tension-stress induces expression of bone morphogenetic protein (BMP)-2 and BMP-4, but not BMP-6, BMP-7, and GDF-5 mRNA, during distraction osteogenesis (1999) J Bone Miner Res, 14 (7), pp. 1084-1095 Carter, D.R., Mechanical loading histories and cortical bone remodeling (1984) Calcif Tissue Int, 36, pp. S19-24 Frost, H.M., The role of changes in mechanical usage set points in the pathogenesis of osteoporosis (1992) J Bone Miner Res, 7 (3), pp. 253-261. , Mar Morris, H.F., Ochi, S., Crum, P., Orenstein, I.H., Winkler, S., AICRG, Part I: a 6-year multicentered, multidisciplinary clinical study of a new and innovative implant design (2004) J Oral Implantol, 30 (3), pp. 125-133. , Jun Chang, P.K., Chen, Y.C., Huang, C.C., Lu, W.H., Chen, Y.C., Tsai, H.H., Distribution of micromotion in implants and alveolar bone with different thread profiles in immediate loading: a finite element study (2012) Int J Oral Maxillofac Implants, 27 (6), pp. e96-101. , Nov-Dec Engelke, W., Decco, O.A., Rau, M.J., Massoni, M.C., Schwarzwaller, W., In vitro evaluation of horizontal implant micromovement in bone specimen with contact endoscopy (2004) Implant Dent, 13 (1), pp. 88-94. , Mar