Artículos de revistas
Aerial Environment In Broiler Housing: Dust And Gases [ambiência Aérea Em Alojamento De Frangos De Corte: Poeira E Gases]
Registro en:
Engenharia Agricola. , v. 27, n. 2, p. 326 - 335, 2007.
1006916
2-s2.0-34848878425
Autor
Naas I.D.A.
Miragliotta M.Y.
Baracho M.D.S.
De Moura D.J.
Institución
Resumen
Air quality in animal production environment has been refereed as an interesting point for studies in environmental control systems with the focus both to the animal health which live in total confinement, as to the workers. The objective of this research was to determine the variation on the aerial environmental quality in two types of broiler housing: conventional (G c) and tunnel type (G t). The total dust values in both houses offered adequate rearing conditions to the birds; however, regarding the inhale dust in the air was above the limits recommended for humans. Carbon monoxide concentration in the heating phase during the evaluated period was above the 10 ppm maximum recommended, and it was higher during the cold season in G t house (30 ppm) when compared to the G c house (18 ppm). Ammonia concentration peaks in the air were above the 20 ppm recommended from the 20 th day of production in both houses and in daily average, for a period higher in G t (4h30) when compared to G t (2h45). Only traces of nitrate oxide and methane were found while carbonic dioxide gas concentration evaluated during daytime met the limits allowed for both birds and labor. 27 2 326 335 AARNIK, A.J.A. ROELOFS, P.F.M.M. ELLEN, H. GUNNIK, H. Dust Sources in Animal Houses. In: INTERNATIONAL SYMPOSIUM ON DUST CONTROL IN ANIMAL PRODUCTION FACILITIES, 1., 1999, Aarhus. Proceedings... Aarhus: Danish Institute of Agricultural Sciences, 1999. p 34-40ABREU, P.G. BAÊTA, F.C. ABREU, V.M.N. SOARES, P.R. PERDOMO, C.C. SILVA, M.A. Umidade da cama e teor de amônia em diferentes sistemas de aquecimento de frangos de corte. In: CONFERÊNCIA APINCO, 16., 1998, Campinas. Anais... Campinas: Fundação Apinco de Ciência e Tecnologias Avícolas, 1998. p.68ACGIH. AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS. TLVs and BEIs - Handbook . Cincinnati: ACGIH, 2001. 132 pBoletim Estatístico SERPA/SP (1985) Boletim Técnico, , BRASIL. MINISTÉRIO DA AGRICULTURA, São Paulo: Delegacia Federal de Agricultura de São Paulo, 28 p CIGR. COMISSION INTERNATIONALE DU GÉNIE RURAL. Climatization of animal houses. 1 st Report of Working Group. Aberdeen: Scottish Farm Buildings Investigation Unit, 1984. 56 pCIGR. COMMISSION INTERNATIONALE DU GÉNIE RURAL. Climatization of animal houses. 2 nd Report of Working Group-Revision. Aberdeen: Scottish Farm Buildings Investigation Unit, 1989. 64 pCIGR. COMMISSION INTERNATIONALE DU GÉNIE RURAL. Climatization of animal houses. Final Report of Working Group. Aberdeen: Scottish Farm Buildings Investigation Unit, 1992. 58 pCONY, A.V., ZOCCHE, Instalações, A.T., equipamentos, Campinas (2001) Anais, 2, pp. 33-50. , CONFERÊNCIA APINCO DE CIÊNCIA E TECNOLOGIAS AVÍCOLAS, 19, Campinas: Fundação Apinco de Ciência e Tecnologias Avícolas CURTIS, S.E., (1983) Environmental management in animal agriculture, , Iowa: Iowa State University Press, 650 p DONHAM, K. A historical overview of research on the hazards of dust in livestock buildings. In: INTERNATIONAL SYMPOSIUM ON DUST CONTROL IN ANIMAL PRODUCTION FACILITIES, 1., 1999. Aarhus, Proceedings... Aarhus: Danish Institute of Agricultural Sciences, 1999. p.13-21HARTUNG, J. SEEDORF, J. Characterization of airborne dust in livestock housing and its effects on animal and environment. In: INTERNATIONAL SYMPOSIUM ON DUST CONTROL IN ANIMAL PRODUCTION FACILITIES, 1., 1999, Aarhus. Proceedings... Aarhus: Danish Institute of Agricultural Sciences, 1999. p.140-53HELLICKSON, M.A., WALKER, J.N., (1983) Ventilation of agricultural structures, , St. Joseph: American Society of Agricultural Engineers, 213 p HYSLOP, N.S.G. Effects of the environment on immunity to disease. In: LIVESTOCK ENVIRONMENT, 1., 1974, Lund. Proceedings... St. Joseph: American Society of Agricultural Engineers, 1974. p.383-90MIRAGLIOTTA, M.Y., (2000) Avaliação dos níveis de amônia em dois sistemas de produção de frangos de corte com ventilação e densidade diferenciados, , 122 f. Dissertação Mestrado em Construções Rurais e Ambiência, Faculdade de Engenharia Agrícola, UNICAMP, Campinas OSHA. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. Particulates not otherwise regulated, total 0500- Manual of Analytical Methods (NMAM). 4 th.ed. USA: NIOSH. 1994 (a). Disponível em http://www.cdc.gov/niosh/nmam/nmammenu.html. Acesso em: 7 maio 2002OSHA. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. Particulates not otherwise regulated, respirable 0600. Manual of Analytical Methods (NMAM). 4.ed. USA: NIOSH. 1994(b). Disponível em http://www.cdc.gov/niosh/nmam/ nmammenu.html. Acesso em: 7 maio 2002PAULA JÚNIOR, D.R. Biodigestores: tecnologia de processos anaeróbios para tratamento de resíduos agroindustriais. Campinas: Faculdade de Engenharia Agrícola, 2004. 16 p. ApostilaPINTO, F.G., CURI, P.R., TOLEDO, M., Evolução da condenação avícola no Estado de São Paulo (1985 a 1990): Tendências anuais e estacionais (1993) Veterinária e Zootecnia, 5, pp. 45-50. , São Paulo, v SAINSBURY, D.W.B., Health problems in intensive animal production (1981) Environmental aspects of housing for animal production, pp. 439-454. , CLARK, J.A, Butterworths: England TAKAI, H. MÖLLER, F. IVERSEN, M. JORSAL, S.E. BILLE-HANSEN, V. Dust control in swine buildings by spraying of rapeseed oil. In: LIVESTOCK ENVIRONMENT SYMPOSIUM, 4., 1993, St. Joseph. Proceedings... St Joseph: American Society of Agricultural Engineering, 1993. p.726-33TAKAI, H. SEEDORF, J. PEDERSEN, S. Dust and endotoxin concentrations in livestock buildings in norther Europe. In: INTERNATIONAL SYMPOSIUM ON DUST CONTROL IN ANIMAL PRODUCTION FACILITIES, 1., 1999, Aarhus-Denmark. Proceedings... Aarhus: Danish Institute of Agricultural Sciences, 1999. p.140-53