Brasil
| Artículos de revistas
Radiant Exposure Effects On Physical Properties Of Methacrylate - And Silorane-composites
dc.creator | Catelan A. | |
dc.creator | Kawano Y. | |
dc.creator | dos Santos P.H. | |
dc.creator | Ambrosano G.M.B. | |
dc.creator | Bedran-Russo A.K. | |
dc.creator | Aguiar F.H.B. | |
dc.date | 2014 | |
dc.date | 2015-06-25T17:53:50Z | |
dc.date | 2015-11-26T14:27:05Z | |
dc.date | 2015-06-25T17:53:50Z | |
dc.date | 2015-11-26T14:27:05Z | |
dc.date.accessioned | 2018-03-28T21:30:10Z | |
dc.date.available | 2018-03-28T21:30:10Z | |
dc.identifier | ||
dc.identifier | Brazilian Journal Of Oral Sciences. Piracicaba Dental School - Unicamp, v. 13, n. 3, p. 168 - 174, 2014. | |
dc.identifier | 16773217 | |
dc.identifier | ||
dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-84908205873&partnerID=40&md5=afcc10862b1d27393fab4a79429835ce | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/86540 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/86540 | |
dc.identifier | 2-s2.0-84908205873 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1246241 | |
dc.description | Aim: To evaluate the effect of different radiant exposures on the degree of conversion (DC), Knoop hardness number (KHN), plasticization (P), water sorption (WS), and solubility (S) of different monomer resin-based composites. Methods: Circular specimens (5 x 2 mm) were manufactured from methacrylate and silorane composite resins, and light-cured at 19.8, 27.8, 39.6, and 55.6 J/cm2, using second-generation LED at 1,390 mW/cm2. After 24 h, DC was obtained using a FT-Raman spectrometer equipped with a Nd:YAG laser, KHN was measured with 50-g load for 15 s, and P was evaluated on the top and bottom surfaces by the percentage of hardness reduction after 24 h immersed in absolute alcohol. WS and S were determined according to ISO 4049. Data were subjected to statistical analysis (α=0.05). Results: Methacrylate material presented higher DC, KHN, P, and WS than silorane (p<0.05). There was no difference in the S values (p>0.05). The increased radiant exposures improved only the KHN (p<0.05). In general, top surfaces showed higher DC and KHN than bottom, for both materials (p<0.05). The increase of the radiant exposure did not improve most physical properties of the composites and were monomerbase dependent. Conclusions: Chemical composition of the composite resins resulted in different physical properties behavior and could affect the clinical longevity of dental restorations, but overall these properties were not influenced by the different radiant exposures evaluated in the study. | |
dc.description | 13 | |
dc.description | 3 | |
dc.description | 168 | |
dc.description | 174 | |
dc.description | Catelan, A., Briso, A.L., Sundfeld, R.H., dos Santos, P.H., Effect of artificial aging on the roughness and microhardness of sealed composites (2010) J Esthet Restor Dent, 22, pp. 324-330 | |
dc.description | Da Rosa Rodolpho, P.A., Donassollo, T.A., Cenci, M.S., Loguércio, A.D., Moraes, R.R., Bronkhorst, E.M., 22-year clinical evaluation of the performance of two posterior composites with different filler characteristics (2011) Dent Mater, 27, pp. 955-963 | |
dc.description | Filho, J.D., Poskus, L.T., Guimarães, J.G., Barcellos, A.A., Silva, E.M., Degree of conversion and plasticization of dimethacrylate-based polymeric matrices: influence of light-curing mode (2008) J Oral Sci, 50, pp. 315-321 | |
dc.description | Baek, D.M., Park, J.K., Son, S.A., Ko, C.C., Garcia-Godoy, F., Kim, H.I., Mechanical properties of composite resins light-cured using blue DPSS laser (2013) Lasers Med Sci, 28, pp. 597-604 | |
dc.description | Van Ende, A., De Munck, J., Mine, A., Lambrechts, P., Van Meerbeek, B., Does a low-shrinking composite induce less stress at the adhesive interface? (2010) Dent Mater, 26, pp. 215-222 | |
dc.description | Weinmann, W., Thalacker, C., Guggenberger, R., Siloranes in dental composites (2005) Dent Mater, 21, pp. 68-74 | |
dc.description | Asmussen, E., Peutzfeldt, A., Influence of selected components on crosslink density in polymer structures (2001) Eur J Oral Sci, 109, pp. 282-285 | |
dc.description | Palin, W.M., Fleming, G.J., Nathwani, H., Burke, F.J., Randall, R.C., In vitro cuspal deflection and microleakage of maxillary premolars restored with novel low-shrink dental composites (2005) Dent Mater, 21, pp. 324-335 | |
dc.description | Duarte Jr., S., Phark, J.H., Varjão, F.M., Sadan, A., Nanoleakage, ultramorphological characteristics, and microtensile bond strengths of a new low-shrinkage composite to dentin after artificial aging (2009) Dent Mater, 25, pp. 589-600 | |
dc.description | Mine, A., De Munck, J., Van Ende, A., Cardoso, M.V., Kuboki, T., Yoshida, Y., TEM characterization of a silorane composite bonded to enamel/ dentin (2010) Dent Mater, 26, pp. 524-532 | |
dc.description | Leprince, J., Palin, W.M., Mullier, T., Devaux, J., Vreven, J., Leloup, G., Investigating filler morphology and mechanical properties of new lowshrinkage resin composite types (2010) J Oral Rehabil, 37, pp. 364-376 | |
dc.description | Aguiar, F.H., Lazzari, C.R., Lima, D.A., Ambrosano, G.M., Lovadino, J.R., Effect of light curing tip distance and resin shade on microhardness of a hybrid resin composite (2005) Braz Oral Res, 19, pp. 302-306 | |
dc.description | Borges, B.C., Souza-Junior, E.J., Catelan, A., Ambrosano, G.M., Paulillo, L.A., Aguiar, F.H., Impact of extended radiant exposure time on polymerization depth of fluoride-containing fissure sealer materials (2011) Acta Odontol Latinoam, 24, pp. 47-51 | |
dc.description | Heo, Y.J., Lee, G.H., Park, J.K., Ro, J.H., García-Godoy, F., Kim, H.I., Effect of energy density on low-shrinkage composite resins: diode-pumped solid state laser versus quartz-tungsten-halogen light-curing unit (2013) Photomed Laser Surg, 31, pp. 28-35 | |
dc.description | Kusgoz, A., Ülker, M., Yesilyurt, C., Yoldas, O.H., Ozil, M., Tanriver, M., Silorane-based composite: depth of cure, surface hardness, degree of conversion, and cervical microleakage in Class II cavities (2011) J Esthet Restor Dent, 23, pp. 324-335 | |
dc.description | Schneider, L.F., Moraes, R.R., Cavalcante, L.M., Sinhoretti, M.A., Correr-Sobrinho, L., Consani, S., Cross-link density evaluation through softening tests: effect of ethanol concentration (2008) Dent Mater, 24, pp. 199-203 | |
dc.description | Opdam, N.J., Bronkhorst, E.M., Loomans, B.A., Huysmans, M.C., 12-year survival of composite vs. amalgam restorations (2010) J Dent Res, 89, pp. 1063-1067 | |
dc.description | Boaro, L.C., Gonçalves, F., Guimarães, T.C., Ferracane, J.L., Pfeifer, C.S., Braga, R.R., Sorption, solubility, shrinkage and mechanical properties of "low-shrinkage" commercial resin composites (2013) Dent Mater, 29, pp. 398-404 | |
dc.description | Gonçalves, F., Kawano, Y., Braga, R.R., Contraction stress related to composite inorganic content (2010) Dent Mater, 26, pp. 704-709 | |
dc.description | Say, E.C., Civelek, A., Nobecourt, A., Ersoy, M., Guleryus, C., Wear and microhardness of different resin composite materials (2003) Oper Dent, 28, pp. 628-634 | |
dc.description | Ferracane, J.L., Hygroscopic and hydrolytic effects in dental polymer networks (2006) Dent Mater, 22, pp. 211-222 | |
dc.description | Giannini, M., Di Francescantonio, M., Pacheco, R.R., Cidreira Boaro, L.C., Braga, R.R., Characterization of water sorption, solubility, and roughness of silorane- and methacrylate-based composite resins (2014) Oper Dent, 39, pp. 264-272 | |
dc.description | Gerhardt, K., Silva, A.S., Rego, G., Sinhoreti, M.A., Salgado, V.E., Schneider, L.F., Bulk and surface properties related to composite filler size (2013) Braz J Oral Sci, 12, pp. 323-329 | |
dc.description | da Silva, E.M., Almeida, G.S., Poskus, L.T., Guimarães, J.G., Relationship between the degree of conversion, solubility and salivary sorption of a hybrid and a nanofill resin composite (2008) J Applied Oral Sci, 16, pp. 161-166 | |
dc.description | Faria-e-Silva, A.L., Lima, A.F., Moraes, R.R., Piva, E., Martins, L.R., Degree of conversion of etch-and-rinse and self-etch adhesives light-cured using QTH or LED (2010) Oper Dent, 35, pp. 649-654 | |
dc.description | Catelan, A., Ambrosano, G.M., Lima, D.A., Marchi, G.M., Aguiar, F.H., Influence of radiant exposure on degree of conversion, water sorption and solubility of self-etch adhesives (2013) Int J Adhes Adhes, 46, pp. 40-43 | |
dc.description | Torres, S.A., Silva, G.C., Maria, D.A., Campos, W.R., Magalhães, C.S., Moreira, A.N., Degree of conversion and hardness of a silorane-based composite resin: effect of light-curing unit and depth (2014) Oper Dent, 39, pp. E137-E146 | |
dc.language | en | |
dc.publisher | Piracicaba Dental School - UNICAMP | |
dc.relation | Brazilian Journal of Oral Sciences | |
dc.rights | aberto | |
dc.source | Scopus | |
dc.title | Radiant Exposure Effects On Physical Properties Of Methacrylate - And Silorane-composites | |
dc.type | Artículos de revistas |